Cargando…
Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device
BACKGROUND: The left atrial appendage (LAA) sealing properties of the Amplatzer Amulet and Watchman FLX devices were compared using cardiac computed tomography (CT) follow-up. METHODS: Single-center cohort study of patients undergoing LAAO between 2017 and 2020. Two consecutive cohorts were enrolled...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977851/ https://www.ncbi.nlm.nih.gov/pubmed/35951214 http://dx.doi.org/10.1007/s10840-022-01336-4 |
_version_ | 1784899385447940096 |
---|---|
author | Korsholm, Kasper Kramer, Anders Andersen, Asger Saw, Jacqueline Nørgaard, Bjarne Linde Jensen, Jesper Møller Nielsen-Kudsk, Jens Erik |
author_facet | Korsholm, Kasper Kramer, Anders Andersen, Asger Saw, Jacqueline Nørgaard, Bjarne Linde Jensen, Jesper Møller Nielsen-Kudsk, Jens Erik |
author_sort | Korsholm, Kasper |
collection | PubMed |
description | BACKGROUND: The left atrial appendage (LAA) sealing properties of the Amplatzer Amulet and Watchman FLX devices were compared using cardiac computed tomography (CT) follow-up. METHODS: Single-center cohort study of patients undergoing LAAO between 2017 and 2020. Two consecutive cohorts were enrolled, one treated with the Amplatzer Amulet (n = 150) up till 2019, and a second cohort treated with the Watchman FLX (n = 150) device from 2019. Cardiac CT was performed 2 months postprocedure. The primary outcome was complete LAA occlusion defined as no visible peri-device leak (PDL) and absence of contrast patency in the distal LAA. Secondary outcomes included PDL, contrast patency without visible PDL, PDL area, and periprocedural complications. RESULTS: Complete occlusion was achieved in 39 (30.5%) of the Amulet group, compared to 89 (71.8%) of the FLX group, p < 0.001. A PDL at the Amulet disc was present in 65 (50.8%), at the lobe in 16 (12.5%), and at both the disc and lobe in 13 (10.2%). For FLX, a PDL was present in 20 (16.1%). Contrast patency without visible PDL was observed in 24 (18.8%) and 15 (12.1%) of the Amulet and FLX group, respectively. The PDL area at the Amulet mid-lobe was 92 mm(2) (59–158) and 32 mm(2) (IQR 28–96) for FLX, p = 0.019. Device-related thrombosis occurred in 1 (0.7%) and 2 (1.3%), respectively (p = 0.99), with periprocedural adverse events occurring in 6 (4%) and 8 (5.3%) of the Amulet and FLX group (p = 0.79). CONCLUSION: Complete LAA occlusion was achieved in a significantly higher proportion treated with the Watchman FLX compared to the Amulet device. PDL was smaller with the FLX than the Amulet. Conceptual device design differences make interpretation of results complex, and additional studies with clinical outcomes are needed. |
format | Online Article Text |
id | pubmed-9977851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-99778512023-03-03 Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device Korsholm, Kasper Kramer, Anders Andersen, Asger Saw, Jacqueline Nørgaard, Bjarne Linde Jensen, Jesper Møller Nielsen-Kudsk, Jens Erik J Interv Card Electrophysiol Article BACKGROUND: The left atrial appendage (LAA) sealing properties of the Amplatzer Amulet and Watchman FLX devices were compared using cardiac computed tomography (CT) follow-up. METHODS: Single-center cohort study of patients undergoing LAAO between 2017 and 2020. Two consecutive cohorts were enrolled, one treated with the Amplatzer Amulet (n = 150) up till 2019, and a second cohort treated with the Watchman FLX (n = 150) device from 2019. Cardiac CT was performed 2 months postprocedure. The primary outcome was complete LAA occlusion defined as no visible peri-device leak (PDL) and absence of contrast patency in the distal LAA. Secondary outcomes included PDL, contrast patency without visible PDL, PDL area, and periprocedural complications. RESULTS: Complete occlusion was achieved in 39 (30.5%) of the Amulet group, compared to 89 (71.8%) of the FLX group, p < 0.001. A PDL at the Amulet disc was present in 65 (50.8%), at the lobe in 16 (12.5%), and at both the disc and lobe in 13 (10.2%). For FLX, a PDL was present in 20 (16.1%). Contrast patency without visible PDL was observed in 24 (18.8%) and 15 (12.1%) of the Amulet and FLX group, respectively. The PDL area at the Amulet mid-lobe was 92 mm(2) (59–158) and 32 mm(2) (IQR 28–96) for FLX, p = 0.019. Device-related thrombosis occurred in 1 (0.7%) and 2 (1.3%), respectively (p = 0.99), with periprocedural adverse events occurring in 6 (4%) and 8 (5.3%) of the Amulet and FLX group (p = 0.79). CONCLUSION: Complete LAA occlusion was achieved in a significantly higher proportion treated with the Watchman FLX compared to the Amulet device. PDL was smaller with the FLX than the Amulet. Conceptual device design differences make interpretation of results complex, and additional studies with clinical outcomes are needed. Springer US 2022-08-11 2023 /pmc/articles/PMC9977851/ /pubmed/35951214 http://dx.doi.org/10.1007/s10840-022-01336-4 Text en © The Author(s) 2022, corrected publication 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Korsholm, Kasper Kramer, Anders Andersen, Asger Saw, Jacqueline Nørgaard, Bjarne Linde Jensen, Jesper Møller Nielsen-Kudsk, Jens Erik Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title | Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title_full | Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title_fullStr | Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title_full_unstemmed | Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title_short | Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device |
title_sort | left atrial appendage sealing performance of the amplatzer amulet and watchman flx device |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977851/ https://www.ncbi.nlm.nih.gov/pubmed/35951214 http://dx.doi.org/10.1007/s10840-022-01336-4 |
work_keys_str_mv | AT korsholmkasper leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT krameranders leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT andersenasger leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT sawjacqueline leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT nørgaardbjarnelinde leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT jensenjespermøller leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice AT nielsenkudskjenserik leftatrialappendagesealingperformanceoftheamplatzeramuletandwatchmanflxdevice |