Cargando…

Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator

This study evaluates the volumetric modulated arc therapy (VMAT) dosimetric comparison between Halcyon ring gantry and TrueBeam c-arm linear accelerators for craniospinal irradiation (CSI) of the neuro-axis. 25 patients, who received treatment for medulloblastoma and primitive neuro-ectodermal tumor...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarkar, Biplab, Biswal, Subhra Snigdha, Shahid, Tanweer, Ghosh, Tanmoy, Bhattacharya, Jibak, De, Arundhati, Mukherjee, Mukti, Ganesh, Tharmarnadar, Cozzi, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977918/
https://www.ncbi.nlm.nih.gov/pubmed/36859485
http://dx.doi.org/10.1038/s41598-023-30429-x
_version_ 1784899398877052928
author Sarkar, Biplab
Biswal, Subhra Snigdha
Shahid, Tanweer
Ghosh, Tanmoy
Bhattacharya, Jibak
De, Arundhati
Mukherjee, Mukti
Ganesh, Tharmarnadar
Cozzi, Luca
author_facet Sarkar, Biplab
Biswal, Subhra Snigdha
Shahid, Tanweer
Ghosh, Tanmoy
Bhattacharya, Jibak
De, Arundhati
Mukherjee, Mukti
Ganesh, Tharmarnadar
Cozzi, Luca
author_sort Sarkar, Biplab
collection PubMed
description This study evaluates the volumetric modulated arc therapy (VMAT) dosimetric comparison between Halcyon ring gantry and TrueBeam c-arm linear accelerators for craniospinal irradiation (CSI) of the neuro-axis. 25 patients, who received treatment for medulloblastoma and primitive neuro-ectodermal tumors between 2018 and 2021, were planned for VMAT in True Beam (TB), and Halcyon (HAL) linear accelerators using 6 MV unflattened (FFF) photon beams (HALFFF and TBFFF). Dose-volume statistics for the target and organs at risk (OARs) and the total number of monitoring units (MUs) in the treatment plans were compared which included dose received by 95% PTV volume (V95%), volume receiving ≥ 107% dose, homogeneity index (HI), conformity index (PI), MU and dose spillage (D10%, D30%, D50%, D70%, D90%). In all 26 OARs were considered of which five were serial and the remaining were parallel structures. For the former, the dose received by 0.2 cm(3), volume = D0.2 cm(3)) were evaluated and for the latter mean dose were evaluated. Both arms were statistically compared with paired sample t-test with a significant value of ≤ 0.05. 11 patients received treatment with the Halcyon and the rest 14 in the TrueBeam C-arm linear accelerator. Patients in the low- and intermediate-risk category (n = 13) received 23.4 Gy in 13 fractions. The remaining patients were in the high-risk category and received 35 Gy in 21 fractions or 36 Gy in 20 fractions. For HALFFF and TBFFF, PTVV95% were 97.5 ± 0.8% and 97.4 ± 0.9% respectively (p = 0.371) while the V107% were 0.6 ± 0.4% and 0.5 ± 0.5 respectively (p = 0.504). However, the number of monitoring units showed statistical significance (p < 0.001) with values of 1331.9 ± 243.4 MU and 1089 ± 206.7 MU respectively for the HAL and TB plans. The differences in spillage dose were also statistically significant, favouring HAL plans at D30% (p = 0.002), D50% (p < 0.001), D70% (p = 0.039), and D90% (p = 0.01) level except for D10% (p = 0.090). Conformity index also showed statistical significance with PI_HAL = 0.9 ± 0.02 and PI_TB = 0.89 ± 0.03 (p = 0.029). For 10 of the 21 parallel structures, the mean dose differences were statistically significant in favouring of HAL plans. Halcyon based VMAT CSI plans are dosimetrically superior in terms of organ dose, especially for the large organs, and offer lower spillage doses than the TrueBeam plans. Plans generated by both linear accelerators are suitable for the patients’ treatments.
format Online
Article
Text
id pubmed-9977918
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-99779182023-03-03 Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator Sarkar, Biplab Biswal, Subhra Snigdha Shahid, Tanweer Ghosh, Tanmoy Bhattacharya, Jibak De, Arundhati Mukherjee, Mukti Ganesh, Tharmarnadar Cozzi, Luca Sci Rep Article This study evaluates the volumetric modulated arc therapy (VMAT) dosimetric comparison between Halcyon ring gantry and TrueBeam c-arm linear accelerators for craniospinal irradiation (CSI) of the neuro-axis. 25 patients, who received treatment for medulloblastoma and primitive neuro-ectodermal tumors between 2018 and 2021, were planned for VMAT in True Beam (TB), and Halcyon (HAL) linear accelerators using 6 MV unflattened (FFF) photon beams (HALFFF and TBFFF). Dose-volume statistics for the target and organs at risk (OARs) and the total number of monitoring units (MUs) in the treatment plans were compared which included dose received by 95% PTV volume (V95%), volume receiving ≥ 107% dose, homogeneity index (HI), conformity index (PI), MU and dose spillage (D10%, D30%, D50%, D70%, D90%). In all 26 OARs were considered of which five were serial and the remaining were parallel structures. For the former, the dose received by 0.2 cm(3), volume = D0.2 cm(3)) were evaluated and for the latter mean dose were evaluated. Both arms were statistically compared with paired sample t-test with a significant value of ≤ 0.05. 11 patients received treatment with the Halcyon and the rest 14 in the TrueBeam C-arm linear accelerator. Patients in the low- and intermediate-risk category (n = 13) received 23.4 Gy in 13 fractions. The remaining patients were in the high-risk category and received 35 Gy in 21 fractions or 36 Gy in 20 fractions. For HALFFF and TBFFF, PTVV95% were 97.5 ± 0.8% and 97.4 ± 0.9% respectively (p = 0.371) while the V107% were 0.6 ± 0.4% and 0.5 ± 0.5 respectively (p = 0.504). However, the number of monitoring units showed statistical significance (p < 0.001) with values of 1331.9 ± 243.4 MU and 1089 ± 206.7 MU respectively for the HAL and TB plans. The differences in spillage dose were also statistically significant, favouring HAL plans at D30% (p = 0.002), D50% (p < 0.001), D70% (p = 0.039), and D90% (p = 0.01) level except for D10% (p = 0.090). Conformity index also showed statistical significance with PI_HAL = 0.9 ± 0.02 and PI_TB = 0.89 ± 0.03 (p = 0.029). For 10 of the 21 parallel structures, the mean dose differences were statistically significant in favouring of HAL plans. Halcyon based VMAT CSI plans are dosimetrically superior in terms of organ dose, especially for the large organs, and offer lower spillage doses than the TrueBeam plans. Plans generated by both linear accelerators are suitable for the patients’ treatments. Nature Publishing Group UK 2023-03-01 /pmc/articles/PMC9977918/ /pubmed/36859485 http://dx.doi.org/10.1038/s41598-023-30429-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Sarkar, Biplab
Biswal, Subhra Snigdha
Shahid, Tanweer
Ghosh, Tanmoy
Bhattacharya, Jibak
De, Arundhati
Mukherjee, Mukti
Ganesh, Tharmarnadar
Cozzi, Luca
Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title_full Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title_fullStr Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title_full_unstemmed Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title_short Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator
title_sort comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between halcyon ring gantry and truebeam c-arm linear accelerator
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977918/
https://www.ncbi.nlm.nih.gov/pubmed/36859485
http://dx.doi.org/10.1038/s41598-023-30429-x
work_keys_str_mv AT sarkarbiplab comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT biswalsubhrasnigdha comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT shahidtanweer comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT ghoshtanmoy comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT bhattacharyajibak comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT dearundhati comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT mukherjeemukti comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT ganeshtharmarnadar comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator
AT cozziluca comparativedosimetricanalysisofvolumetricmodulatedarctherapybasedcraniospinalirradiationplansbetweenhalcyonringgantryandtruebeamcarmlinearaccelerator