Cargando…

Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis

Objectives: To study the mechanical sensitivity of different intervertebral disc and bone material parameters and ligaments under different force configurations and magnitudes in the scoliosis model. Methods: The finite element model of a 21-year-old female is built using computed tomography. Local...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Wenqing, Zhang, Tianyuan, Yang, Junlin, Qian, Yu, Dong, Yating
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9978187/
https://www.ncbi.nlm.nih.gov/pubmed/36873369
http://dx.doi.org/10.3389/fbioe.2023.1111449
_version_ 1784899462839140352
author Wei, Wenqing
Zhang, Tianyuan
Yang, Junlin
Qian, Yu
Dong, Yating
author_facet Wei, Wenqing
Zhang, Tianyuan
Yang, Junlin
Qian, Yu
Dong, Yating
author_sort Wei, Wenqing
collection PubMed
description Objectives: To study the mechanical sensitivity of different intervertebral disc and bone material parameters and ligaments under different force configurations and magnitudes in the scoliosis model. Methods: The finite element model of a 21-year-old female is built using computed tomography. Local range of motion testing and global bending simulations are performed for the model verification. Subsequently, Five force of different directions and configurations were applied to the finite element model applying the brace pad position. The material parameters of the model were related to different spinal flexibilities and included different material parameters of cortical bone, cancellous bone, nucleus and annulus. The virtual X-ray technique measured Cobb angle, thoracic Lordosis, and lumbar Kyphosis. Results: The difference in peak displacement is 9.28 mm, 19.99 mm, 27.06 mm, 43.99 mm, and 50.1 mm under five force configurations. The maximum Cobb angle difference due to material parameters are 4.7° and 6.2°, which are converted to thoracic and lumbar in-brace correction difference of 18% and 15.5%. The maximum difference in Kyphosis and Lordosis angle is 4.4° and 5.8°. The average thoracic and lumbar Cobb angle variation difference in intervertebral disc control group is larger than that in bone control group, while the average Kyphosis and Lordosis angle is inverse. The displacement distribution of models with or without ligaments is similar, with a peak displacement difference of 1.3 mm in C5. The peak stress occurred at the junction of the cortical bone and ribs. Conclusion: Spinal flexibility largely influences the treatment effect of the brace. The intervertebral disc has a greater effect on the Cobb angle, the bone has a greater effect on the Kyphosis and Lordosis angles, and the rotation is affected by both. Patient-specific material is the key to increasing accuracy in the personalized finite element model. This study provides a scientific basis for using controllable brace treatment for scoliosis.
format Online
Article
Text
id pubmed-9978187
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-99781872023-03-03 Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis Wei, Wenqing Zhang, Tianyuan Yang, Junlin Qian, Yu Dong, Yating Front Bioeng Biotechnol Bioengineering and Biotechnology Objectives: To study the mechanical sensitivity of different intervertebral disc and bone material parameters and ligaments under different force configurations and magnitudes in the scoliosis model. Methods: The finite element model of a 21-year-old female is built using computed tomography. Local range of motion testing and global bending simulations are performed for the model verification. Subsequently, Five force of different directions and configurations were applied to the finite element model applying the brace pad position. The material parameters of the model were related to different spinal flexibilities and included different material parameters of cortical bone, cancellous bone, nucleus and annulus. The virtual X-ray technique measured Cobb angle, thoracic Lordosis, and lumbar Kyphosis. Results: The difference in peak displacement is 9.28 mm, 19.99 mm, 27.06 mm, 43.99 mm, and 50.1 mm under five force configurations. The maximum Cobb angle difference due to material parameters are 4.7° and 6.2°, which are converted to thoracic and lumbar in-brace correction difference of 18% and 15.5%. The maximum difference in Kyphosis and Lordosis angle is 4.4° and 5.8°. The average thoracic and lumbar Cobb angle variation difference in intervertebral disc control group is larger than that in bone control group, while the average Kyphosis and Lordosis angle is inverse. The displacement distribution of models with or without ligaments is similar, with a peak displacement difference of 1.3 mm in C5. The peak stress occurred at the junction of the cortical bone and ribs. Conclusion: Spinal flexibility largely influences the treatment effect of the brace. The intervertebral disc has a greater effect on the Cobb angle, the bone has a greater effect on the Kyphosis and Lordosis angles, and the rotation is affected by both. Patient-specific material is the key to increasing accuracy in the personalized finite element model. This study provides a scientific basis for using controllable brace treatment for scoliosis. Frontiers Media S.A. 2023-02-16 /pmc/articles/PMC9978187/ /pubmed/36873369 http://dx.doi.org/10.3389/fbioe.2023.1111449 Text en Copyright © 2023 Wei, Zhang, Yang, Qian and Dong. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Wei, Wenqing
Zhang, Tianyuan
Yang, Junlin
Qian, Yu
Dong, Yating
Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title_full Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title_fullStr Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title_full_unstemmed Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title_short Material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
title_sort material sensitivity of patient-specific finite element models in the brace treatment of scoliosis
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9978187/
https://www.ncbi.nlm.nih.gov/pubmed/36873369
http://dx.doi.org/10.3389/fbioe.2023.1111449
work_keys_str_mv AT weiwenqing materialsensitivityofpatientspecificfiniteelementmodelsinthebracetreatmentofscoliosis
AT zhangtianyuan materialsensitivityofpatientspecificfiniteelementmodelsinthebracetreatmentofscoliosis
AT yangjunlin materialsensitivityofpatientspecificfiniteelementmodelsinthebracetreatmentofscoliosis
AT qianyu materialsensitivityofpatientspecificfiniteelementmodelsinthebracetreatmentofscoliosis
AT dongyating materialsensitivityofpatientspecificfiniteelementmodelsinthebracetreatmentofscoliosis