Cargando…

Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column

BACKGROUND: Few methods exist for the analysis of the soil nitrification inhibitor 3,4-dimethyl-1H-pyrazole (3,4-DMP), which is a pesticide with the ability to reduce the production of nitrogenous greenhouse gases in soils as a result of fertilizer application. Due to its small size and polar nature...

Descripción completa

Detalles Bibliográficos
Autores principales: Doran, Gregory S, Condon, Jason R, Kaveney, Brooke F
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9978597/
https://www.ncbi.nlm.nih.gov/pubmed/36285423
http://dx.doi.org/10.1093/jaoacint/qsac126
_version_ 1784899556594417664
author Doran, Gregory S
Condon, Jason R
Kaveney, Brooke F
author_facet Doran, Gregory S
Condon, Jason R
Kaveney, Brooke F
author_sort Doran, Gregory S
collection PubMed
description BACKGROUND: Few methods exist for the analysis of the soil nitrification inhibitor 3,4-dimethyl-1H-pyrazole (3,4-DMP), which is a pesticide with the ability to reduce the production of nitrogenous greenhouse gases in soils as a result of fertilizer application. Due to its small size and polar nature, 3,4-DMP can be difficult to retain on an LC column, which makes diversion of a co-extracted soil matrix away from the MS/MS impossible. OBJECTIVE: The current study aims to better control the retention time (RT) of 3,4-DMP. Additionally, 3,4-DMP-15N2 was synthesized and used as an internal standard for the soil extraction of 3,4-DMP. METHODS: Perfluoroalkanoic acids were used as ion-pair reagents and were compared for their abilities to improve peak shape and RT, to better separate 3,4-DMP from the soil matrix without the need for cleanup during soil extraction. RESULTS: RTs increased with both the carbon number and the concentration of the perfluoroalkanoic acid, and this improved peak shape and height. Perfluorooctanoic acid performed best, and improved peak height (PH) and shape were obtained by increasing the flow rate, resulting in a better S/N than from formic acid. The method provided a 10-fold improvement limit of quantitation on the most sensitive existing method and the use of 3,4-DMP-15N2 as an internal standard resulted in recoveries of 101–107%. CONCLUSION: Ion-pair reagents drastically increased the retention of 3,4-DMP and allowed the re-use of old LC columns that may otherwise be discarded. Improved separation of 3,4-DMP from the soil matrix allowed much of the matrix to be diverted from the MS/MS spray chamber. HIGHLIGHTS: Greater control of 3,4-DMP retention by the LC column resulting in the ability to separate 3,4-DMP from the soil matrix. The inclusion of ion-pair reagents only in the aqueous phase reduced ionization suppression of the analytes in the MS source.
format Online
Article
Text
id pubmed-9978597
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-99785972023-03-03 Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column Doran, Gregory S Condon, Jason R Kaveney, Brooke F J AOAC Int Short Communication BACKGROUND: Few methods exist for the analysis of the soil nitrification inhibitor 3,4-dimethyl-1H-pyrazole (3,4-DMP), which is a pesticide with the ability to reduce the production of nitrogenous greenhouse gases in soils as a result of fertilizer application. Due to its small size and polar nature, 3,4-DMP can be difficult to retain on an LC column, which makes diversion of a co-extracted soil matrix away from the MS/MS impossible. OBJECTIVE: The current study aims to better control the retention time (RT) of 3,4-DMP. Additionally, 3,4-DMP-15N2 was synthesized and used as an internal standard for the soil extraction of 3,4-DMP. METHODS: Perfluoroalkanoic acids were used as ion-pair reagents and were compared for their abilities to improve peak shape and RT, to better separate 3,4-DMP from the soil matrix without the need for cleanup during soil extraction. RESULTS: RTs increased with both the carbon number and the concentration of the perfluoroalkanoic acid, and this improved peak shape and height. Perfluorooctanoic acid performed best, and improved peak height (PH) and shape were obtained by increasing the flow rate, resulting in a better S/N than from formic acid. The method provided a 10-fold improvement limit of quantitation on the most sensitive existing method and the use of 3,4-DMP-15N2 as an internal standard resulted in recoveries of 101–107%. CONCLUSION: Ion-pair reagents drastically increased the retention of 3,4-DMP and allowed the re-use of old LC columns that may otherwise be discarded. Improved separation of 3,4-DMP from the soil matrix allowed much of the matrix to be diverted from the MS/MS spray chamber. HIGHLIGHTS: Greater control of 3,4-DMP retention by the LC column resulting in the ability to separate 3,4-DMP from the soil matrix. The inclusion of ion-pair reagents only in the aqueous phase reduced ionization suppression of the analytes in the MS source. Oxford University Press 2022-10-26 /pmc/articles/PMC9978597/ /pubmed/36285423 http://dx.doi.org/10.1093/jaoacint/qsac126 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of AOAC INTERNATIONAL. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communication
Doran, Gregory S
Condon, Jason R
Kaveney, Brooke F
Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title_full Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title_fullStr Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title_full_unstemmed Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title_short Quantification of 3,4-Dimethyl-1H-Pyrazole Using Ion-Pair LC–MS/MS on a Reversed-Phase Column
title_sort quantification of 3,4-dimethyl-1h-pyrazole using ion-pair lc–ms/ms on a reversed-phase column
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9978597/
https://www.ncbi.nlm.nih.gov/pubmed/36285423
http://dx.doi.org/10.1093/jaoacint/qsac126
work_keys_str_mv AT dorangregorys quantificationof34dimethyl1hpyrazoleusingionpairlcmsmsonareversedphasecolumn
AT condonjasonr quantificationof34dimethyl1hpyrazoleusingionpairlcmsmsonareversedphasecolumn
AT kaveneybrookef quantificationof34dimethyl1hpyrazoleusingionpairlcmsmsonareversedphasecolumn