Cargando…
Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma
BACKGROUND: Although traditional surgical procedures for glaucoma (such as trabeculectomy and tube-shunt implantation) can significantly reduce intraocular pressure (IOP), they are associated with numerous complications, some of which are vision-threatening, or involve prolonged recovery or a highly...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979478/ https://www.ncbi.nlm.nih.gov/pubmed/36859515 http://dx.doi.org/10.1186/s40662-022-00322-1 |
_version_ | 1784899734984458240 |
---|---|
author | Ahmed, Iqbal Ike K. Sadruddin, Omar Panarelli, Joseph F. |
author_facet | Ahmed, Iqbal Ike K. Sadruddin, Omar Panarelli, Joseph F. |
author_sort | Ahmed, Iqbal Ike K. |
collection | PubMed |
description | BACKGROUND: Although traditional surgical procedures for glaucoma (such as trabeculectomy and tube-shunt implantation) can significantly reduce intraocular pressure (IOP), they are associated with numerous complications, some of which are vision-threatening, or involve prolonged recovery or a highly intensive postoperative course. Micro-invasive glaucoma surgery (MIGS) procedures have shown better safety but reduced efficacy in achieving target IOP. Combinations of these methods have led to the development of subconjunctival micro-invasive procedures with safety comparable to traditional surgery and greater efficacy than minimally invasive methods. This review describes the use of one of these devices, the poly(styrene-block-isobutylene-block-styrene) (SIBS)-based PreserFlo MicroShunt (Santen, Emeryville, CA), in the surgical treatment of patients with glaucoma. MAIN TEXT: The MicroShunt is an 8.5-mm tube made of an inert polymer with no endplate, an internal diameter of 70 μm, and fins intended to prevent peritubular flow and anchor the device within the sclera to prevent proximal migration into the eye. Following ab externo implantation, the tube provides a conduit for flow of aqueous humor from the anterior chamber into the subconjunctival/sub-Tenon space. Clinical trials to date have shown that, when paired with mitomycin C (MMC) treatment, MicroShunt implantation significantly reduced both IOP and the number of glaucoma medications. These IOP-lowering results were found both when surgery was performed alone and with phacoemulsification. The MicroShunt also showed a safety profile comparable to that of traditional filtering surgery. CONCLUSIONS: The MicroShunt and other novel subconjunctival procedures have shown substantial IOP reductions while mitigating hypotony-related complications. MMC, which modulates fibrosis and scarring postoperatively, is essential to surgical success. Randomized, long-term clinical trials will further clarify the role of controlled micro-incisional device-assisted ab externo glaucoma filtering surgery in long-term glaucoma management. |
format | Online Article Text |
id | pubmed-9979478 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99794782023-03-03 Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma Ahmed, Iqbal Ike K. Sadruddin, Omar Panarelli, Joseph F. Eye Vis (Lond) Review BACKGROUND: Although traditional surgical procedures for glaucoma (such as trabeculectomy and tube-shunt implantation) can significantly reduce intraocular pressure (IOP), they are associated with numerous complications, some of which are vision-threatening, or involve prolonged recovery or a highly intensive postoperative course. Micro-invasive glaucoma surgery (MIGS) procedures have shown better safety but reduced efficacy in achieving target IOP. Combinations of these methods have led to the development of subconjunctival micro-invasive procedures with safety comparable to traditional surgery and greater efficacy than minimally invasive methods. This review describes the use of one of these devices, the poly(styrene-block-isobutylene-block-styrene) (SIBS)-based PreserFlo MicroShunt (Santen, Emeryville, CA), in the surgical treatment of patients with glaucoma. MAIN TEXT: The MicroShunt is an 8.5-mm tube made of an inert polymer with no endplate, an internal diameter of 70 μm, and fins intended to prevent peritubular flow and anchor the device within the sclera to prevent proximal migration into the eye. Following ab externo implantation, the tube provides a conduit for flow of aqueous humor from the anterior chamber into the subconjunctival/sub-Tenon space. Clinical trials to date have shown that, when paired with mitomycin C (MMC) treatment, MicroShunt implantation significantly reduced both IOP and the number of glaucoma medications. These IOP-lowering results were found both when surgery was performed alone and with phacoemulsification. The MicroShunt also showed a safety profile comparable to that of traditional filtering surgery. CONCLUSIONS: The MicroShunt and other novel subconjunctival procedures have shown substantial IOP reductions while mitigating hypotony-related complications. MMC, which modulates fibrosis and scarring postoperatively, is essential to surgical success. Randomized, long-term clinical trials will further clarify the role of controlled micro-incisional device-assisted ab externo glaucoma filtering surgery in long-term glaucoma management. BioMed Central 2023-03-02 /pmc/articles/PMC9979478/ /pubmed/36859515 http://dx.doi.org/10.1186/s40662-022-00322-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Review Ahmed, Iqbal Ike K. Sadruddin, Omar Panarelli, Joseph F. Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title | Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title_full | Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title_fullStr | Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title_full_unstemmed | Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title_short | Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma |
title_sort | subconjunctival filtration in evolution: current evidence on microshunt implantation for treating patients with glaucoma |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979478/ https://www.ncbi.nlm.nih.gov/pubmed/36859515 http://dx.doi.org/10.1186/s40662-022-00322-1 |
work_keys_str_mv | AT ahmediqbalikek subconjunctivalfiltrationinevolutioncurrentevidenceonmicroshuntimplantationfortreatingpatientswithglaucoma AT sadruddinomar subconjunctivalfiltrationinevolutioncurrentevidenceonmicroshuntimplantationfortreatingpatientswithglaucoma AT panarellijosephf subconjunctivalfiltrationinevolutioncurrentevidenceonmicroshuntimplantationfortreatingpatientswithglaucoma |