Cargando…
Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
OBJECTIVE: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three cannulated cancellous screws (CCS). METHODS: First, we developed three different ve...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979525/ https://www.ncbi.nlm.nih.gov/pubmed/36859241 http://dx.doi.org/10.1186/s12938-023-01083-1 |
_version_ | 1784899743795642368 |
---|---|
author | Huang, Shaolong Zhang, Yazhong Zhang, Xu Zhou, Chengqiang Li, Wenbo Wang, Yunqing Wang, Bin Zhu, Ziqiang |
author_facet | Huang, Shaolong Zhang, Yazhong Zhang, Xu Zhou, Chengqiang Li, Wenbo Wang, Yunqing Wang, Bin Zhu, Ziqiang |
author_sort | Huang, Shaolong |
collection | PubMed |
description | OBJECTIVE: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three cannulated cancellous screws (CCS). METHODS: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively. Two experimental groups were set up: the FNS group and the CCS group. Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mises stress (VMS), and its internal fixation components. Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021. In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement. RESULTS: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mises stress. Clinically, we followed up on 87 patients for an average of 12 months. FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score. CONCLUSION: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures. There is potential for FNS to become a new treatment option for vertical femoral neck fractures. |
format | Online Article Text |
id | pubmed-9979525 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99795252023-03-03 Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis Huang, Shaolong Zhang, Yazhong Zhang, Xu Zhou, Chengqiang Li, Wenbo Wang, Yunqing Wang, Bin Zhu, Ziqiang Biomed Eng Online Research OBJECTIVE: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three cannulated cancellous screws (CCS). METHODS: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively. Two experimental groups were set up: the FNS group and the CCS group. Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mises stress (VMS), and its internal fixation components. Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021. In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement. RESULTS: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mises stress. Clinically, we followed up on 87 patients for an average of 12 months. FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score. CONCLUSION: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures. There is potential for FNS to become a new treatment option for vertical femoral neck fractures. BioMed Central 2023-03-02 /pmc/articles/PMC9979525/ /pubmed/36859241 http://dx.doi.org/10.1186/s12938-023-01083-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Huang, Shaolong Zhang, Yazhong Zhang, Xu Zhou, Chengqiang Li, Wenbo Wang, Yunqing Wang, Bin Zhu, Ziqiang Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title | Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title_full | Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title_fullStr | Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title_full_unstemmed | Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title_short | Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
title_sort | comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979525/ https://www.ncbi.nlm.nih.gov/pubmed/36859241 http://dx.doi.org/10.1186/s12938-023-01083-1 |
work_keys_str_mv | AT huangshaolong comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT zhangyazhong comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT zhangxu comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT zhouchengqiang comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT liwenbo comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT wangyunqing comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT wangbin comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis AT zhuziqiang comparisonoffemoralnecksystemandthreecannulatedcancellousscrewsinthetreatmentofverticalfemoralneckfracturesclinicalobservationandfiniteelementanalysis |