Cargando…

Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments

Low-cost aerosol sensors open routes to exposure assessment and air monitoring in various indoor and outdoor environments. This study evaluated the accuracy of GeoAir2––a recently developed low-cost particulate matter (PM) monitor––using two types of aerosols (salt and dust), and the effect of chang...

Descripción completa

Detalles Bibliográficos
Autores principales: Streuber, Dillon, Park, Yoo Min, Sousan, Sinan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979595/
https://www.ncbi.nlm.nih.gov/pubmed/36876290
http://dx.doi.org/10.4209/aaqr.220119
_version_ 1784899755225120768
author Streuber, Dillon
Park, Yoo Min
Sousan, Sinan
author_facet Streuber, Dillon
Park, Yoo Min
Sousan, Sinan
author_sort Streuber, Dillon
collection PubMed
description Low-cost aerosol sensors open routes to exposure assessment and air monitoring in various indoor and outdoor environments. This study evaluated the accuracy of GeoAir2––a recently developed low-cost particulate matter (PM) monitor––using two types of aerosols (salt and dust), and the effect of changes in relative humidity on its measurements in laboratory settings. For the accuracy experiments, 32 units of GeoAir2 were used, and for the humidity experiments, 3 units of GeoAir2 were used, alongside the OPC-N3 low-cost sensor and MiniWRAS reference instrument. The normal distribution of slopes between the salt and dust aerosols was compared for the accuracy experiments. In addition, the performance of GeoAir2 in indoor environments was evaluated compared to the pDR-1500 reference instrument by collocating GeoAir2 and pDR-1500 at three different homes for five days. For salt and dust aerosols smaller than 2.5 μm (PM(2.5)), both GeoAir2 (r = 0.96–0.99) and OPC-N3 (r = 0.98–0.99) were highly correlated with the MiniWRAS reference instrument. However, GeoAir2 was less influenced by changes in humidity than OPC-N3. While GeoAir2 reported an increase in mass concentrations ranging from 100% to 137% for low and high concentrations, an increase between 181% and 425% was observed for OPC-N3. The normal distribution of the slopes for the salt aerosols was narrower than dust aerosol, which shows closer slope similarities for salt aerosols. This study also found that GeoAir2 was highly correlated with the pDR-1500 reference instrument in indoor environments (r = 0.80–0.99). These results demonstrate potential for GeoAir2 for indoor air monitoring and exposure assessments.
format Online
Article
Text
id pubmed-9979595
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-99795952023-03-02 Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments Streuber, Dillon Park, Yoo Min Sousan, Sinan Aerosol Air Qual Res Article Low-cost aerosol sensors open routes to exposure assessment and air monitoring in various indoor and outdoor environments. This study evaluated the accuracy of GeoAir2––a recently developed low-cost particulate matter (PM) monitor––using two types of aerosols (salt and dust), and the effect of changes in relative humidity on its measurements in laboratory settings. For the accuracy experiments, 32 units of GeoAir2 were used, and for the humidity experiments, 3 units of GeoAir2 were used, alongside the OPC-N3 low-cost sensor and MiniWRAS reference instrument. The normal distribution of slopes between the salt and dust aerosols was compared for the accuracy experiments. In addition, the performance of GeoAir2 in indoor environments was evaluated compared to the pDR-1500 reference instrument by collocating GeoAir2 and pDR-1500 at three different homes for five days. For salt and dust aerosols smaller than 2.5 μm (PM(2.5)), both GeoAir2 (r = 0.96–0.99) and OPC-N3 (r = 0.98–0.99) were highly correlated with the MiniWRAS reference instrument. However, GeoAir2 was less influenced by changes in humidity than OPC-N3. While GeoAir2 reported an increase in mass concentrations ranging from 100% to 137% for low and high concentrations, an increase between 181% and 425% was observed for OPC-N3. The normal distribution of the slopes for the salt aerosols was narrower than dust aerosol, which shows closer slope similarities for salt aerosols. This study also found that GeoAir2 was highly correlated with the pDR-1500 reference instrument in indoor environments (r = 0.80–0.99). These results demonstrate potential for GeoAir2 for indoor air monitoring and exposure assessments. 2022-08 2022-06-01 /pmc/articles/PMC9979595/ /pubmed/36876290 http://dx.doi.org/10.4209/aaqr.220119 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.
spellingShingle Article
Streuber, Dillon
Park, Yoo Min
Sousan, Sinan
Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title_full Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title_fullStr Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title_full_unstemmed Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title_short Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
title_sort laboratory and field evaluations of the geoair2 air quality monitor for use in indoor environments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9979595/
https://www.ncbi.nlm.nih.gov/pubmed/36876290
http://dx.doi.org/10.4209/aaqr.220119
work_keys_str_mv AT streuberdillon laboratoryandfieldevaluationsofthegeoair2airqualitymonitorforuseinindoorenvironments
AT parkyoomin laboratoryandfieldevaluationsofthegeoair2airqualitymonitorforuseinindoorenvironments
AT sousansinan laboratoryandfieldevaluationsofthegeoair2airqualitymonitorforuseinindoorenvironments