Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?

BACKGROUND: To assess the clinical and radiographical outcomes of 3-level anterior cervical discectomy and fusion (ACDF) with a 3D-printed titanium cage in treating degenerative cervical spondylosis. METHODS: In this study, 25 patients with degenerative cervical spondylosis who underwent 3-level ACD...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Shanxi, Fang, Xuan, Qu, Yunkun, Lu, Rui, Yu, Xiaojun, Jing, Shaoze, Ding, Qing, Liu, Chaoxu, Wu, Hua, Liu, Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9982008/
https://www.ncbi.nlm.nih.gov/pubmed/36874465
http://dx.doi.org/10.3389/fsurg.2023.1096080
_version_ 1784900231404453888
author Wang, Shanxi
Fang, Xuan
Qu, Yunkun
Lu, Rui
Yu, Xiaojun
Jing, Shaoze
Ding, Qing
Liu, Chaoxu
Wu, Hua
Liu, Yang
author_facet Wang, Shanxi
Fang, Xuan
Qu, Yunkun
Lu, Rui
Yu, Xiaojun
Jing, Shaoze
Ding, Qing
Liu, Chaoxu
Wu, Hua
Liu, Yang
author_sort Wang, Shanxi
collection PubMed
description BACKGROUND: To assess the clinical and radiographical outcomes of 3-level anterior cervical discectomy and fusion (ACDF) with a 3D-printed titanium cage in treating degenerative cervical spondylosis. METHODS: In this study, 25 patients with degenerative cervical spondylosis who underwent 3-level ACDF using a 3D-printed titanium cage from March 2019 to June 2021 were retrospectively enrolled. The patient-reported outcome measures (PROMs) were evaluated by visual analog scale (VAS) for the neck (VAS-neck) and arm pain (VAS-arm), Neck Disability Index (NDI) score, Japanese Orthopedic Association (JOA) score, SF-12 concise health survey, and the Odom criteria. The radiographical parameters, including C2-C7 lordosis, segmental angle, segmental height, and subsidence, were assessed. The mean duration of follow-up was 25.6 months. RESULTS: Bony fusion was achieved in all patients (100%). In three patients (12%) mild dysphagia was observed during the follow-up. The VAS-neck, VAS-arm, NDI score, JOA score, SF-12 score, C2-C7 lordosis, and segmental angle improved noticeably at the latest follow-up. Based on the Odom criteria, 22 patients (88%) reported satisfactory (excellent or good). The mean loss of C2-C7 lordosis and segmental angle between the immediate postoperative and the latest follow-up values were 1.6° ± 0.5° and 1.1° ± 0.5°, respectively. The mean subsidence was 0.9 ± 0.6 mm. CONCLUSION: In patients with multi-level degenerative cervical spondylosis, 3-level ACDF using the 3D-printed titanium cage can effectively relieve the symptoms, stabilize the spine, and restore segmental height and cervical curvature. It is proven to be a reliable option for patients with 3-level degenerative cervical spondylosis. However, a future comparative study involving a larger population and longer follow-up time may be required to further evaluate the safety, efficacy and outcomes of our preliminary results.
format Online
Article
Text
id pubmed-9982008
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-99820082023-03-04 Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis? Wang, Shanxi Fang, Xuan Qu, Yunkun Lu, Rui Yu, Xiaojun Jing, Shaoze Ding, Qing Liu, Chaoxu Wu, Hua Liu, Yang Front Surg Surgery BACKGROUND: To assess the clinical and radiographical outcomes of 3-level anterior cervical discectomy and fusion (ACDF) with a 3D-printed titanium cage in treating degenerative cervical spondylosis. METHODS: In this study, 25 patients with degenerative cervical spondylosis who underwent 3-level ACDF using a 3D-printed titanium cage from March 2019 to June 2021 were retrospectively enrolled. The patient-reported outcome measures (PROMs) were evaluated by visual analog scale (VAS) for the neck (VAS-neck) and arm pain (VAS-arm), Neck Disability Index (NDI) score, Japanese Orthopedic Association (JOA) score, SF-12 concise health survey, and the Odom criteria. The radiographical parameters, including C2-C7 lordosis, segmental angle, segmental height, and subsidence, were assessed. The mean duration of follow-up was 25.6 months. RESULTS: Bony fusion was achieved in all patients (100%). In three patients (12%) mild dysphagia was observed during the follow-up. The VAS-neck, VAS-arm, NDI score, JOA score, SF-12 score, C2-C7 lordosis, and segmental angle improved noticeably at the latest follow-up. Based on the Odom criteria, 22 patients (88%) reported satisfactory (excellent or good). The mean loss of C2-C7 lordosis and segmental angle between the immediate postoperative and the latest follow-up values were 1.6° ± 0.5° and 1.1° ± 0.5°, respectively. The mean subsidence was 0.9 ± 0.6 mm. CONCLUSION: In patients with multi-level degenerative cervical spondylosis, 3-level ACDF using the 3D-printed titanium cage can effectively relieve the symptoms, stabilize the spine, and restore segmental height and cervical curvature. It is proven to be a reliable option for patients with 3-level degenerative cervical spondylosis. However, a future comparative study involving a larger population and longer follow-up time may be required to further evaluate the safety, efficacy and outcomes of our preliminary results. Frontiers Media S.A. 2023-02-17 /pmc/articles/PMC9982008/ /pubmed/36874465 http://dx.doi.org/10.3389/fsurg.2023.1096080 Text en © 2023 Wang, Fang, Qu, Lu, Yu, Jing, Ding, Liu, Wu and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Wang, Shanxi
Fang, Xuan
Qu, Yunkun
Lu, Rui
Yu, Xiaojun
Jing, Shaoze
Ding, Qing
Liu, Chaoxu
Wu, Hua
Liu, Yang
Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title_full Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title_fullStr Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title_full_unstemmed Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title_short Is 3D-printed Titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
title_sort is 3d-printed titanium cage a reliable option for 3-level anterior cervical discectomy and fusion in treating degenerative cervical spondylosis?
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9982008/
https://www.ncbi.nlm.nih.gov/pubmed/36874465
http://dx.doi.org/10.3389/fsurg.2023.1096080
work_keys_str_mv AT wangshanxi is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT fangxuan is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT quyunkun is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT lurui is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT yuxiaojun is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT jingshaoze is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT dingqing is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT liuchaoxu is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT wuhua is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis
AT liuyang is3dprintedtitaniumcageareliableoptionfor3levelanteriorcervicaldiscectomyandfusionintreatingdegenerativecervicalspondylosis