Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature
Robotic gynecologic surgery is associated with the use of steep Trendelenburg positioning. Steep Trendelenburg is necessary to provide optimal exposure to the pelvis but is associated with an increased risk of non-surgical complications such as suboptimal ventilation, facial and laryngeal edema, inc...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9982598/ https://www.ncbi.nlm.nih.gov/pubmed/36873858 http://dx.doi.org/10.1016/j.gore.2023.101151 |
_version_ | 1784900364315656192 |
---|---|
author | Swartz, Alison Z. Novoa y Arruga Novoa, Victoria Hassoun, Jenine S. Crispens, Marta A. Prescott, Lauren S. |
author_facet | Swartz, Alison Z. Novoa y Arruga Novoa, Victoria Hassoun, Jenine S. Crispens, Marta A. Prescott, Lauren S. |
author_sort | Swartz, Alison Z. |
collection | PubMed |
description | Robotic gynecologic surgery is associated with the use of steep Trendelenburg positioning. Steep Trendelenburg is necessary to provide optimal exposure to the pelvis but is associated with an increased risk of non-surgical complications such as suboptimal ventilation, facial and laryngeal edema, increased intraocular and intracranial pressure as well as neurologic injury. Several case reports have described otorrhagia after robotic assisted surgery; however, there are limited reports on the risk of tympanic membrane perforation. To our knowledge, there are no published reports on tympanic membrane perforation in gynecologic nor gynecologic oncology surgery. We report two cases of perioperative tympanic membrane rupture and bloody otorrhagia associated with robot-assisted gynecologic surgery. In both cases otolaryngology/Ear Nose and Throat (ENT) was consulted, and the perforations resolved with conservative management. |
format | Online Article Text |
id | pubmed-9982598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-99825982023-03-04 Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature Swartz, Alison Z. Novoa y Arruga Novoa, Victoria Hassoun, Jenine S. Crispens, Marta A. Prescott, Lauren S. Gynecol Oncol Rep Case Report Robotic gynecologic surgery is associated with the use of steep Trendelenburg positioning. Steep Trendelenburg is necessary to provide optimal exposure to the pelvis but is associated with an increased risk of non-surgical complications such as suboptimal ventilation, facial and laryngeal edema, increased intraocular and intracranial pressure as well as neurologic injury. Several case reports have described otorrhagia after robotic assisted surgery; however, there are limited reports on the risk of tympanic membrane perforation. To our knowledge, there are no published reports on tympanic membrane perforation in gynecologic nor gynecologic oncology surgery. We report two cases of perioperative tympanic membrane rupture and bloody otorrhagia associated with robot-assisted gynecologic surgery. In both cases otolaryngology/Ear Nose and Throat (ENT) was consulted, and the perforations resolved with conservative management. Elsevier 2023-02-22 /pmc/articles/PMC9982598/ /pubmed/36873858 http://dx.doi.org/10.1016/j.gore.2023.101151 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Swartz, Alison Z. Novoa y Arruga Novoa, Victoria Hassoun, Jenine S. Crispens, Marta A. Prescott, Lauren S. Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title | Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title_full | Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title_fullStr | Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title_full_unstemmed | Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title_short | Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature |
title_sort | robotic-assisted gynecologic surgery associated tympanic membrane perforation: a report of two cases and review of the literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9982598/ https://www.ncbi.nlm.nih.gov/pubmed/36873858 http://dx.doi.org/10.1016/j.gore.2023.101151 |
work_keys_str_mv | AT swartzalisonz roboticassistedgynecologicsurgeryassociatedtympanicmembraneperforationareportoftwocasesandreviewoftheliterature AT novoayarruganovoavictoria roboticassistedgynecologicsurgeryassociatedtympanicmembraneperforationareportoftwocasesandreviewoftheliterature AT hassounjenines roboticassistedgynecologicsurgeryassociatedtympanicmembraneperforationareportoftwocasesandreviewoftheliterature AT crispensmartaa roboticassistedgynecologicsurgeryassociatedtympanicmembraneperforationareportoftwocasesandreviewoftheliterature AT prescottlaurens roboticassistedgynecologicsurgeryassociatedtympanicmembraneperforationareportoftwocasesandreviewoftheliterature |