Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983374/ https://www.ncbi.nlm.nih.gov/pubmed/36874891 http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388 |
_version_ | 1784900531458670592 |
---|---|
author | Jha, Amrit Dua, Apoorv Gadkari, Alok Yadav, Amit Kumar Goyal, Navneet |
author_facet | Jha, Amrit Dua, Apoorv Gadkari, Alok Yadav, Amit Kumar Goyal, Navneet |
author_sort | Jha, Amrit |
collection | PubMed |
description | INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of the flexor and extensor tendons are maintained. Factors affecting management are fracture location, type of fracture, soft-tissue injury, and fracture stability. CASE REPORT: A 26-year-gentlemen, right hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger treated with debridement, wound wash, and external fixator frame made with K wire and needle cap. Fracture united in 6 weeks with good hand function and the full range of motion of the hand. CONCLUSION: Mini fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted. |
format | Online Article Text |
id | pubmed-9983374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-99833742023-03-04 Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report Jha, Amrit Dua, Apoorv Gadkari, Alok Yadav, Amit Kumar Goyal, Navneet J Orthop Case Rep Case Report INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of the flexor and extensor tendons are maintained. Factors affecting management are fracture location, type of fracture, soft-tissue injury, and fracture stability. CASE REPORT: A 26-year-gentlemen, right hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger treated with debridement, wound wash, and external fixator frame made with K wire and needle cap. Fracture united in 6 weeks with good hand function and the full range of motion of the hand. CONCLUSION: Mini fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted. Indian Orthopaedic Research Group 2022-10 2022-10 /pmc/articles/PMC9983374/ /pubmed/36874891 http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Jha, Amrit Dua, Apoorv Gadkari, Alok Yadav, Amit Kumar Goyal, Navneet Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title | Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title_full | Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title_fullStr | Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title_full_unstemmed | Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title_short | Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report |
title_sort | needle cap external fixator for proximal phalanx fracture – a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983374/ https://www.ncbi.nlm.nih.gov/pubmed/36874891 http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388 |
work_keys_str_mv | AT jhaamrit needlecapexternalfixatorforproximalphalanxfractureacasereport AT duaapoorv needlecapexternalfixatorforproximalphalanxfractureacasereport AT gadkarialok needlecapexternalfixatorforproximalphalanxfractureacasereport AT yadavamitkumar needlecapexternalfixatorforproximalphalanxfractureacasereport AT goyalnavneet needlecapexternalfixatorforproximalphalanxfractureacasereport |