Cargando…

Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report

INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Jha, Amrit, Dua, Apoorv, Gadkari, Alok, Yadav, Amit Kumar, Goyal, Navneet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983374/
https://www.ncbi.nlm.nih.gov/pubmed/36874891
http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388
_version_ 1784900531458670592
author Jha, Amrit
Dua, Apoorv
Gadkari, Alok
Yadav, Amit Kumar
Goyal, Navneet
author_facet Jha, Amrit
Dua, Apoorv
Gadkari, Alok
Yadav, Amit Kumar
Goyal, Navneet
author_sort Jha, Amrit
collection PubMed
description INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of the flexor and extensor tendons are maintained. Factors affecting management are fracture location, type of fracture, soft-tissue injury, and fracture stability. CASE REPORT: A 26-year-gentlemen, right hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger treated with debridement, wound wash, and external fixator frame made with K wire and needle cap. Fracture united in 6 weeks with good hand function and the full range of motion of the hand. CONCLUSION: Mini fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted.
format Online
Article
Text
id pubmed-9983374
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-99833742023-03-04 Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report Jha, Amrit Dua, Apoorv Gadkari, Alok Yadav, Amit Kumar Goyal, Navneet J Orthop Case Rep Case Report INTRODUCTION: Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of the flexor and extensor tendons are maintained. Factors affecting management are fracture location, type of fracture, soft-tissue injury, and fracture stability. CASE REPORT: A 26-year-gentlemen, right hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger treated with debridement, wound wash, and external fixator frame made with K wire and needle cap. Fracture united in 6 weeks with good hand function and the full range of motion of the hand. CONCLUSION: Mini fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted. Indian Orthopaedic Research Group 2022-10 2022-10 /pmc/articles/PMC9983374/ /pubmed/36874891 http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Jha, Amrit
Dua, Apoorv
Gadkari, Alok
Yadav, Amit Kumar
Goyal, Navneet
Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title_full Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title_fullStr Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title_full_unstemmed Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title_short Needle Cap External Fixator for Proximal Phalanx Fracture – A Case Report
title_sort needle cap external fixator for proximal phalanx fracture – a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983374/
https://www.ncbi.nlm.nih.gov/pubmed/36874891
http://dx.doi.org/10.13107/jocr.2022.v12.i10.3388
work_keys_str_mv AT jhaamrit needlecapexternalfixatorforproximalphalanxfractureacasereport
AT duaapoorv needlecapexternalfixatorforproximalphalanxfractureacasereport
AT gadkarialok needlecapexternalfixatorforproximalphalanxfractureacasereport
AT yadavamitkumar needlecapexternalfixatorforproximalphalanxfractureacasereport
AT goyalnavneet needlecapexternalfixatorforproximalphalanxfractureacasereport