Cargando…

Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study

Objective: The main objective of this study is the evaluation of the accuracy and reliability of a handheld point of care ultrasound device (POCUS-hd) for intrauterine pregnancy (IUP) detection compared to comprehensive reference transabdominal ultrasound (TU). The secondary objectives were to evalu...

Descripción completa

Detalles Bibliográficos
Autores principales: Skendi, Mariela, Liard, Roxane, Besacier, Charlotte, Correas, Jean-Michel, Moussaoui, Sohela, Chastang, Julie, Ibanez, Gladys
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983726/
https://www.ncbi.nlm.nih.gov/pubmed/36896381
http://dx.doi.org/10.24908/pocus.v7i2.15458
_version_ 1784900607923978240
author Skendi, Mariela
Liard, Roxane
Besacier, Charlotte
Correas, Jean-Michel
Moussaoui, Sohela
Chastang, Julie
Ibanez, Gladys
author_facet Skendi, Mariela
Liard, Roxane
Besacier, Charlotte
Correas, Jean-Michel
Moussaoui, Sohela
Chastang, Julie
Ibanez, Gladys
author_sort Skendi, Mariela
collection PubMed
description Objective: The main objective of this study is the evaluation of the accuracy and reliability of a handheld point of care ultrasound device (POCUS-hd) for intrauterine pregnancy (IUP) detection compared to comprehensive reference transabdominal ultrasound (TU). The secondary objectives were to evaluate POCUS-hd for intrauterine pregnancy (IUP) detection compared to transabdominal and transvaginal ultrasound (TUTV), evaluate the inter-device agreement and inter-rater reliability of gestational age during early pregnancy. Methods: It is an observational transverse study with consecutive patient recruitment. Two blinded operators systematically used POCUS-hd and reference transabdominal ultrasound for IUP diagnosis. The accuracy of POCUS-hd for IUP diagnosis was expressed as sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV). The gestational age (GA) was assessed based on the crown-rump length. The reliability and agreement of gestational age evaluation were assessed by Bland-Altman plots, kappa statistic, and intraclass correlation coefficients (ICC). Results: POCUS-hd compared to TU had a sensitivity of 95-100%, a specifcity of 90-100%, PPV of 95-100% and NPV of 90-100%. Inter-rater agreement for IUP detection using POCUS-hd was very good, kappa=1.0; CI95% [0.9-1.0]. The inter-device agreement limits (mean difference ± 2SD) for GA were: -3 to +2.3 days by Operator 1, -3.4 to +3.3 days by Operator 2 for POCUS-hd vs. TU and -3.1 to +2.3 days for POCUS-hd versus TUTV. Conclusion: This handheld POCUS device is an accurate and reliable diagnostic tool that can be used for IUP positive findings and GA assessment during early pregnancy by clinicians in family planning settings or general practice.
format Online
Article
Text
id pubmed-9983726
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-99837262023-03-08 Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study Skendi, Mariela Liard, Roxane Besacier, Charlotte Correas, Jean-Michel Moussaoui, Sohela Chastang, Julie Ibanez, Gladys POCUS J Medicine Objective: The main objective of this study is the evaluation of the accuracy and reliability of a handheld point of care ultrasound device (POCUS-hd) for intrauterine pregnancy (IUP) detection compared to comprehensive reference transabdominal ultrasound (TU). The secondary objectives were to evaluate POCUS-hd for intrauterine pregnancy (IUP) detection compared to transabdominal and transvaginal ultrasound (TUTV), evaluate the inter-device agreement and inter-rater reliability of gestational age during early pregnancy. Methods: It is an observational transverse study with consecutive patient recruitment. Two blinded operators systematically used POCUS-hd and reference transabdominal ultrasound for IUP diagnosis. The accuracy of POCUS-hd for IUP diagnosis was expressed as sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV). The gestational age (GA) was assessed based on the crown-rump length. The reliability and agreement of gestational age evaluation were assessed by Bland-Altman plots, kappa statistic, and intraclass correlation coefficients (ICC). Results: POCUS-hd compared to TU had a sensitivity of 95-100%, a specifcity of 90-100%, PPV of 95-100% and NPV of 90-100%. Inter-rater agreement for IUP detection using POCUS-hd was very good, kappa=1.0; CI95% [0.9-1.0]. The inter-device agreement limits (mean difference ± 2SD) for GA were: -3 to +2.3 days by Operator 1, -3.4 to +3.3 days by Operator 2 for POCUS-hd vs. TU and -3.1 to +2.3 days for POCUS-hd versus TUTV. Conclusion: This handheld POCUS device is an accurate and reliable diagnostic tool that can be used for IUP positive findings and GA assessment during early pregnancy by clinicians in family planning settings or general practice. 2022-11-21 /pmc/articles/PMC9983726/ /pubmed/36896381 http://dx.doi.org/10.24908/pocus.v7i2.15458 Text en Copyright (c) 2022 Mariela Skendi, Roxane Liard, Charlotte Besacier, Jean-Michel Correas, Sohela Moussaoui, Julie Chastang, Gladys Ibanez https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Medicine
Skendi, Mariela
Liard, Roxane
Besacier, Charlotte
Correas, Jean-Michel
Moussaoui, Sohela
Chastang, Julie
Ibanez, Gladys
Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title_full Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title_fullStr Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title_full_unstemmed Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title_short Intrauterine Pregnancy Detection and Gestational Age Assessment During Early Pregnancy by a Handheld Point-Of-Care Ultrasound Device Compared to a High-End Ultrasound System. An Accuracy and Reliability Study
title_sort intrauterine pregnancy detection and gestational age assessment during early pregnancy by a handheld point-of-care ultrasound device compared to a high-end ultrasound system. an accuracy and reliability study
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9983726/
https://www.ncbi.nlm.nih.gov/pubmed/36896381
http://dx.doi.org/10.24908/pocus.v7i2.15458
work_keys_str_mv AT skendimariela intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT liardroxane intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT besaciercharlotte intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT correasjeanmichel intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT moussaouisohela intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT chastangjulie intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy
AT ibanezgladys intrauterinepregnancydetectionandgestationalageassessmentduringearlypregnancybyahandheldpointofcareultrasounddevicecomparedtoahighendultrasoundsystemanaccuracyandreliabilitystudy