Cargando…
Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood
Transcriptome profiling of human whole blood is used to discover biomarkers of diseases and to assess phenotypic traits. Recently, finger-stick blood collection systems have allowed a less invasive and quicker collection of peripheral blood. Such non-invasive sampling of small volumes of blood offer...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984369/ https://www.ncbi.nlm.nih.gov/pubmed/36869090 http://dx.doi.org/10.1038/s41598-023-30629-5 |
_version_ | 1784900732926820352 |
---|---|
author | Kalikiri, Mahesh Kumar Reddy Manjunath, Harshitha Shobha Vempalli, Fazulur Rehaman Mathew, Lisa Sara Liu, Li Wang, Li Wang, Guishuang Wang, Kun Soloviov, Oleksandr Lorenz, Stephan Tomei, Sara |
author_facet | Kalikiri, Mahesh Kumar Reddy Manjunath, Harshitha Shobha Vempalli, Fazulur Rehaman Mathew, Lisa Sara Liu, Li Wang, Li Wang, Guishuang Wang, Kun Soloviov, Oleksandr Lorenz, Stephan Tomei, Sara |
author_sort | Kalikiri, Mahesh Kumar Reddy |
collection | PubMed |
description | Transcriptome profiling of human whole blood is used to discover biomarkers of diseases and to assess phenotypic traits. Recently, finger-stick blood collection systems have allowed a less invasive and quicker collection of peripheral blood. Such non-invasive sampling of small volumes of blood offers practical advantages. The quality of gene expression data is strictly dependent on the steps used for the sample collection, extraction, preparation and sequencing. Here we have: (i) compared the manual and automated RNA extraction of small volumes of blood using the Tempus Spin RNA isolation kit and the MagMAX for Stabilized Blood RNA Isolation kit , respectively; and (ii) assessed the effect of TURBO DNA Free treatment on the transcriptomic data of RNA isolated from small volumes of blood. We have used the QuantSeq 3′ FWD mRNA-Seq Library Prep kit to prepare RNA-seq libraries, which were sequenced on the Illumina NextSeq 500 system. The samples isolated manually displayed a higher variability in the transcriptomic data as compared to the other samples. The TURBO DNA Free treatment affected the RNA samples negatively, decreasing the RNA yield and reducing the quality and reproducibility of the transcriptomic data. We conclude that automated extraction systems should be preferred over manual extraction systems for data consistency, and that the TURBO DNA Free treatment should be avoided when working on RNA samples isolated manually from small volumes of blood. |
format | Online Article Text |
id | pubmed-9984369 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-99843692023-03-05 Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood Kalikiri, Mahesh Kumar Reddy Manjunath, Harshitha Shobha Vempalli, Fazulur Rehaman Mathew, Lisa Sara Liu, Li Wang, Li Wang, Guishuang Wang, Kun Soloviov, Oleksandr Lorenz, Stephan Tomei, Sara Sci Rep Article Transcriptome profiling of human whole blood is used to discover biomarkers of diseases and to assess phenotypic traits. Recently, finger-stick blood collection systems have allowed a less invasive and quicker collection of peripheral blood. Such non-invasive sampling of small volumes of blood offers practical advantages. The quality of gene expression data is strictly dependent on the steps used for the sample collection, extraction, preparation and sequencing. Here we have: (i) compared the manual and automated RNA extraction of small volumes of blood using the Tempus Spin RNA isolation kit and the MagMAX for Stabilized Blood RNA Isolation kit , respectively; and (ii) assessed the effect of TURBO DNA Free treatment on the transcriptomic data of RNA isolated from small volumes of blood. We have used the QuantSeq 3′ FWD mRNA-Seq Library Prep kit to prepare RNA-seq libraries, which were sequenced on the Illumina NextSeq 500 system. The samples isolated manually displayed a higher variability in the transcriptomic data as compared to the other samples. The TURBO DNA Free treatment affected the RNA samples negatively, decreasing the RNA yield and reducing the quality and reproducibility of the transcriptomic data. We conclude that automated extraction systems should be preferred over manual extraction systems for data consistency, and that the TURBO DNA Free treatment should be avoided when working on RNA samples isolated manually from small volumes of blood. Nature Publishing Group UK 2023-03-03 /pmc/articles/PMC9984369/ /pubmed/36869090 http://dx.doi.org/10.1038/s41598-023-30629-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Kalikiri, Mahesh Kumar Reddy Manjunath, Harshitha Shobha Vempalli, Fazulur Rehaman Mathew, Lisa Sara Liu, Li Wang, Li Wang, Guishuang Wang, Kun Soloviov, Oleksandr Lorenz, Stephan Tomei, Sara Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title | Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title_full | Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title_fullStr | Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title_full_unstemmed | Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title_short | Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood |
title_sort | technical assessment of different extraction methods and transcriptome profiling of rna isolated from small volumes of blood |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984369/ https://www.ncbi.nlm.nih.gov/pubmed/36869090 http://dx.doi.org/10.1038/s41598-023-30629-5 |
work_keys_str_mv | AT kalikirimaheshkumarreddy technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT manjunathharshithashobha technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT vempallifazulurrehaman technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT mathewlisasara technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT liuli technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT wangli technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT wangguishuang technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT wangkun technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT soloviovoleksandr technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT lorenzstephan technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood AT tomeisara technicalassessmentofdifferentextractionmethodsandtranscriptomeprofilingofrnaisolatedfromsmallvolumesofblood |