A high sensitivity Cherenkov detector for prompt gamma timing and time imaging

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex d...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacquet, Maxime, Ansari, Saba, Gallin-Martel, Marie-Laure, André, Adélie, Boursier, Yannick, Dupont, Mathieu, Es-smimih, Jilali, Gallin-Martel, Laurent, Hérault, Joël, Hoarau, Christophe, Hofverberg, Johan-Petter, Maneval, Daniel, Morel, Christian, Muraz, Jean-François, Salicis, Fabrice, Marcatili, Sara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984540/
https://www.ncbi.nlm.nih.gov/pubmed/36869125
http://dx.doi.org/10.1038/s41598-023-30712-x
_version_ 1784900766481252352
author Jacquet, Maxime
Ansari, Saba
Gallin-Martel, Marie-Laure
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Es-smimih, Jilali
Gallin-Martel, Laurent
Hérault, Joël
Hoarau, Christophe
Hofverberg, Johan-Petter
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Salicis, Fabrice
Marcatili, Sara
author_facet Jacquet, Maxime
Ansari, Saba
Gallin-Martel, Marie-Laure
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Es-smimih, Jilali
Gallin-Martel, Laurent
Hérault, Joël
Hoarau, Christophe
Hofverberg, Johan-Petter
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Salicis, Fabrice
Marcatili, Sara
author_sort Jacquet, Maxime
collection PubMed
description We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. The sensitivity of this technique depends on both the system time resolution and the beam intensity. At reduced intensities (Single Proton Regime—SPR), a millimetric proton range sensitivity can be achieved, provided the overall PG plus proton TOF can be measured with a 235 ps (FWHM) time resolution. At nominal beam intensities, a sensitivity of a few mm can still be obtained by increasing the number of incident protons included in the monitoring procedure. In this work we focus on the experimental feasibility of PGTI in SPR through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). Since PG emission is a rare phenomenon, TIARA design is led by the concomitant optimisation of its detection efficiency and Signal to Noise Ratio (SNR). The PG module that we developed is composed of a small PbF[Formula: see text] crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This module is currently read in time coincidence with a diamond-based beam monitor placed upstream the target/patient to measure the proton time of arrival. TIARA will be eventually composed of 30 identical modules uniformly arranged around the target. The absence of a collimation system and the use of Cherenkov radiators are both crucial to increase the detection efficiency and the SNR, respectively. A first prototype of the TIARA block detector was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2[Formula: see text] with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.
format Online
Article
Text
id pubmed-9984540
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-99845402023-03-05 A high sensitivity Cherenkov detector for prompt gamma timing and time imaging Jacquet, Maxime Ansari, Saba Gallin-Martel, Marie-Laure André, Adélie Boursier, Yannick Dupont, Mathieu Es-smimih, Jilali Gallin-Martel, Laurent Hérault, Joël Hoarau, Christophe Hofverberg, Johan-Petter Maneval, Daniel Morel, Christian Muraz, Jean-François Salicis, Fabrice Marcatili, Sara Sci Rep Article We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. The sensitivity of this technique depends on both the system time resolution and the beam intensity. At reduced intensities (Single Proton Regime—SPR), a millimetric proton range sensitivity can be achieved, provided the overall PG plus proton TOF can be measured with a 235 ps (FWHM) time resolution. At nominal beam intensities, a sensitivity of a few mm can still be obtained by increasing the number of incident protons included in the monitoring procedure. In this work we focus on the experimental feasibility of PGTI in SPR through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). Since PG emission is a rare phenomenon, TIARA design is led by the concomitant optimisation of its detection efficiency and Signal to Noise Ratio (SNR). The PG module that we developed is composed of a small PbF[Formula: see text] crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This module is currently read in time coincidence with a diamond-based beam monitor placed upstream the target/patient to measure the proton time of arrival. TIARA will be eventually composed of 30 identical modules uniformly arranged around the target. The absence of a collimation system and the use of Cherenkov radiators are both crucial to increase the detection efficiency and the SNR, respectively. A first prototype of the TIARA block detector was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2[Formula: see text] with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan. Nature Publishing Group UK 2023-03-03 /pmc/articles/PMC9984540/ /pubmed/36869125 http://dx.doi.org/10.1038/s41598-023-30712-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Jacquet, Maxime
Ansari, Saba
Gallin-Martel, Marie-Laure
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Es-smimih, Jilali
Gallin-Martel, Laurent
Hérault, Joël
Hoarau, Christophe
Hofverberg, Johan-Petter
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Salicis, Fabrice
Marcatili, Sara
A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title_full A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title_fullStr A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title_full_unstemmed A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title_short A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
title_sort high sensitivity cherenkov detector for prompt gamma timing and time imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984540/
https://www.ncbi.nlm.nih.gov/pubmed/36869125
http://dx.doi.org/10.1038/s41598-023-30712-x
work_keys_str_mv AT jacquetmaxime ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT ansarisaba ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT gallinmartelmarielaure ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT andreadelie ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT boursieryannick ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT dupontmathieu ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT essmimihjilali ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT gallinmartellaurent ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT heraultjoel ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT hoarauchristophe ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT hofverbergjohanpetter ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT manevaldaniel ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT morelchristian ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT murazjeanfrancois ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT salicisfabrice ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT marcatilisara ahighsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT jacquetmaxime highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT ansarisaba highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT gallinmartelmarielaure highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT andreadelie highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT boursieryannick highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT dupontmathieu highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT essmimihjilali highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT gallinmartellaurent highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT heraultjoel highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT hoarauchristophe highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT hofverbergjohanpetter highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT manevaldaniel highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT morelchristian highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT murazjeanfrancois highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT salicisfabrice highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging
AT marcatilisara highsensitivitycherenkovdetectorforpromptgammatimingandtimeimaging