Cargando…

Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column

Highly hydrophilic compounds such as nicotinamide metabolites are very difficult to separate via high-performance liquid chromatography (HPLC) using octadecyl (C(18)) columns. In general, for the separation of hydrophilic compounds, hydrophilic interaction liquid chromatography (HILIC) columns are u...

Descripción completa

Detalles Bibliográficos
Autores principales: Ozaki, Makoto, Shimotsuma, Motoshi, Hirose, Tsunehisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984678/
https://www.ncbi.nlm.nih.gov/pubmed/36879763
http://dx.doi.org/10.1016/j.mex.2023.102061
_version_ 1784900783633858560
author Ozaki, Makoto
Shimotsuma, Motoshi
Hirose, Tsunehisa
author_facet Ozaki, Makoto
Shimotsuma, Motoshi
Hirose, Tsunehisa
author_sort Ozaki, Makoto
collection PubMed
description Highly hydrophilic compounds such as nicotinamide metabolites are very difficult to separate via high-performance liquid chromatography (HPLC) using octadecyl (C(18)) columns. In general, for the separation of hydrophilic compounds, hydrophilic interaction liquid chromatography (HILIC) columns are used instead of reversed phase chromatography using C(18) columns. However, HILIC columns generally obey complex separation mechanisms because ionic interactions are involved in the retention process, which hinders the optimization of the separation conditions. Additionally, the resulting peak shapes are disturbed when large amounts of aqueous samples are injected. This study demonstrates that COSMOSIL PBr columns, in which both hydrophobic and dispersive interactions occur, show high retention for various hydrophilic compounds under similar separation conditions as those used with C(18) columns. Specifically, using a COSMOSIL PBr column, 11 nicotinamide metabolites could be separated under simpler conditions than those used previously with C(18) columns, affording better peak shape for each compound. The applicability of the method was evaluated using a tomato sample, from which the nicotinamide metabolites were successfully separated. The results show that the COSMOSIL PBr column is a good alternative to the C(18) column for a good separation of all the peaks, including impurity peaks.
format Online
Article
Text
id pubmed-9984678
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99846782023-03-05 Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column Ozaki, Makoto Shimotsuma, Motoshi Hirose, Tsunehisa MethodsX Protocol Article Highly hydrophilic compounds such as nicotinamide metabolites are very difficult to separate via high-performance liquid chromatography (HPLC) using octadecyl (C(18)) columns. In general, for the separation of hydrophilic compounds, hydrophilic interaction liquid chromatography (HILIC) columns are used instead of reversed phase chromatography using C(18) columns. However, HILIC columns generally obey complex separation mechanisms because ionic interactions are involved in the retention process, which hinders the optimization of the separation conditions. Additionally, the resulting peak shapes are disturbed when large amounts of aqueous samples are injected. This study demonstrates that COSMOSIL PBr columns, in which both hydrophobic and dispersive interactions occur, show high retention for various hydrophilic compounds under similar separation conditions as those used with C(18) columns. Specifically, using a COSMOSIL PBr column, 11 nicotinamide metabolites could be separated under simpler conditions than those used previously with C(18) columns, affording better peak shape for each compound. The applicability of the method was evaluated using a tomato sample, from which the nicotinamide metabolites were successfully separated. The results show that the COSMOSIL PBr column is a good alternative to the C(18) column for a good separation of all the peaks, including impurity peaks. Elsevier 2023-02-08 /pmc/articles/PMC9984678/ /pubmed/36879763 http://dx.doi.org/10.1016/j.mex.2023.102061 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Protocol Article
Ozaki, Makoto
Shimotsuma, Motoshi
Hirose, Tsunehisa
Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title_full Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title_fullStr Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title_full_unstemmed Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title_short Separation of highly hydrophilic nicotinamide metabolites using a COSMOSIL PBr column
title_sort separation of highly hydrophilic nicotinamide metabolites using a cosmosil pbr column
topic Protocol Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9984678/
https://www.ncbi.nlm.nih.gov/pubmed/36879763
http://dx.doi.org/10.1016/j.mex.2023.102061
work_keys_str_mv AT ozakimakoto separationofhighlyhydrophilicnicotinamidemetabolitesusingacosmosilpbrcolumn
AT shimotsumamotoshi separationofhighlyhydrophilicnicotinamidemetabolitesusingacosmosilpbrcolumn
AT hirosetsunehisa separationofhighlyhydrophilicnicotinamidemetabolitesusingacosmosilpbrcolumn