Cargando…

Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta

AIM: The accuracy of ultrasound findings in predicting the incidence of morbidly adherent placenta has been evaluated previously. In this study, we assessed the sensitivity and specificity of different quantitative findings of color Doppler and grayscale ultrasonography in predicting morbidly adhere...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadeghi Ardakani, Fatemeh, Tara, Fatemeh, Mahmoud Ahmadzade, Amir, Saghafi, Nafiseh, Seilanian Toosi, Farrokh, Khoroushi, Farzaneh, Emadzadeh, Maryam, Mirzaeian, Sara, Aminzadeh, Behzad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9985180/
https://www.ncbi.nlm.nih.gov/pubmed/36880002
http://dx.doi.org/10.15557/JoU.2023.0002
_version_ 1784900897805959168
author Sadeghi Ardakani, Fatemeh
Tara, Fatemeh
Mahmoud Ahmadzade, Amir
Saghafi, Nafiseh
Seilanian Toosi, Farrokh
Khoroushi, Farzaneh
Emadzadeh, Maryam
Mirzaeian, Sara
Aminzadeh, Behzad
author_facet Sadeghi Ardakani, Fatemeh
Tara, Fatemeh
Mahmoud Ahmadzade, Amir
Saghafi, Nafiseh
Seilanian Toosi, Farrokh
Khoroushi, Farzaneh
Emadzadeh, Maryam
Mirzaeian, Sara
Aminzadeh, Behzad
author_sort Sadeghi Ardakani, Fatemeh
collection PubMed
description AIM: The accuracy of ultrasound findings in predicting the incidence of morbidly adherent placenta has been evaluated previously. In this study, we assessed the sensitivity and specificity of different quantitative findings of color Doppler and grayscale ultrasonography in predicting morbidly adherent placenta. MATERIAL AND METHODS: In this prospective cohort study, all pregnant women over 20 weeks of gestational age with anterior placenta and a history of previous cesarean section were evaluated for inclusion. Various ultrasound findings were measured. The non-parametric receiver operating characteristic curves, the area under the curve, and the cut-off values were assessed. RESULTS: A total of 120 patients were ultimately included for analysis, of whom 15 had morbidly adherent placenta. The two groups were significantly different regarding the number of vessels. Based on color Doppler ultrasonography, in predicting the morbidly adherent placenta, more than two intraplecental echolucent zones with color flow had 93% and 98% sensitivity and specificity, respectively. According to grayscale ultrasonography, more than thirteen intraplacental echolucent zones had the sensitivity and specificity of 86% and 80% in predicting morbidly adherent placenta, respectively. Echolucent zone >11 mm at non-fetal surface had a sensitivity of 93% and a specificity of 66% in detecting morbidly adherent placenta. CONCLUSIONS: According to the results, the quantitative findings of color Doppler ultrasound have considerable sensitivity and specificity in detecting morbidly adherent placenta. More than two echolucent zones with color flow are recommended as the main diagnostic parameter indicating the presence of morbidly adherent placenta with a sensitivity of 93% and a specificity of 98%.
format Online
Article
Text
id pubmed-9985180
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-99851802023-03-05 Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta Sadeghi Ardakani, Fatemeh Tara, Fatemeh Mahmoud Ahmadzade, Amir Saghafi, Nafiseh Seilanian Toosi, Farrokh Khoroushi, Farzaneh Emadzadeh, Maryam Mirzaeian, Sara Aminzadeh, Behzad J Ultrason Research Paper AIM: The accuracy of ultrasound findings in predicting the incidence of morbidly adherent placenta has been evaluated previously. In this study, we assessed the sensitivity and specificity of different quantitative findings of color Doppler and grayscale ultrasonography in predicting morbidly adherent placenta. MATERIAL AND METHODS: In this prospective cohort study, all pregnant women over 20 weeks of gestational age with anterior placenta and a history of previous cesarean section were evaluated for inclusion. Various ultrasound findings were measured. The non-parametric receiver operating characteristic curves, the area under the curve, and the cut-off values were assessed. RESULTS: A total of 120 patients were ultimately included for analysis, of whom 15 had morbidly adherent placenta. The two groups were significantly different regarding the number of vessels. Based on color Doppler ultrasonography, in predicting the morbidly adherent placenta, more than two intraplecental echolucent zones with color flow had 93% and 98% sensitivity and specificity, respectively. According to grayscale ultrasonography, more than thirteen intraplacental echolucent zones had the sensitivity and specificity of 86% and 80% in predicting morbidly adherent placenta, respectively. Echolucent zone >11 mm at non-fetal surface had a sensitivity of 93% and a specificity of 66% in detecting morbidly adherent placenta. CONCLUSIONS: According to the results, the quantitative findings of color Doppler ultrasound have considerable sensitivity and specificity in detecting morbidly adherent placenta. More than two echolucent zones with color flow are recommended as the main diagnostic parameter indicating the presence of morbidly adherent placenta with a sensitivity of 93% and a specificity of 98%. Sciendo 2023-02-28 /pmc/articles/PMC9985180/ /pubmed/36880002 http://dx.doi.org/10.15557/JoU.2023.0002 Text en © 2023 Fatemeh Sadeghi Ardakani, Fatemeh Tara, Amir Mahmoud Ahmadzade, Nafiseh Saghafi, Farrokh Seilanian Toosi, Farzaneh Khoroushi, Maryam Emadzadeh, Sara Mirzaeian, Behzad Aminzadeh, published by Sciendo https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Research Paper
Sadeghi Ardakani, Fatemeh
Tara, Fatemeh
Mahmoud Ahmadzade, Amir
Saghafi, Nafiseh
Seilanian Toosi, Farrokh
Khoroushi, Farzaneh
Emadzadeh, Maryam
Mirzaeian, Sara
Aminzadeh, Behzad
Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title_full Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title_fullStr Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title_full_unstemmed Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title_short Evaluation of the Relationship Between Quantitative Ultrasound Findings and Morbidly Adherent Placenta
title_sort evaluation of the relationship between quantitative ultrasound findings and morbidly adherent placenta
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9985180/
https://www.ncbi.nlm.nih.gov/pubmed/36880002
http://dx.doi.org/10.15557/JoU.2023.0002
work_keys_str_mv AT sadeghiardakanifatemeh evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT tarafatemeh evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT mahmoudahmadzadeamir evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT saghafinafiseh evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT seilaniantoosifarrokh evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT khoroushifarzaneh evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT emadzadehmaryam evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT mirzaeiansara evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta
AT aminzadehbehzad evaluationoftherelationshipbetweenquantitativeultrasoundfindingsandmorbidlyadherentplacenta