Cargando…
AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review
Aspiration catheters are widely used for thrombectomy either alone or in combination with a stent-retriever, with a distal inner diameter and trackability keys to their success. In an illustrative case series, we report our clinical experience with AXS Vecta (Stryker Neurovascular, Fremont, CA, USA)...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Interventional Neuroradiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9986352/ https://www.ncbi.nlm.nih.gov/pubmed/36328761 http://dx.doi.org/10.5469/neuroint.2022.00283 |
_version_ | 1784901147614511104 |
---|---|
author | Settecase, Fabio Kim, Warren T. English, Joey D. |
author_facet | Settecase, Fabio Kim, Warren T. English, Joey D. |
author_sort | Settecase, Fabio |
collection | PubMed |
description | Aspiration catheters are widely used for thrombectomy either alone or in combination with a stent-retriever, with a distal inner diameter and trackability keys to their success. In an illustrative case series, we report our clinical experience with AXS Vecta (Stryker Neurovascular, Fremont, CA, USA), available in both 0.071-inch and 0.074-inch distal inner diameters, including the first 2 Vecta 74 cases reported. A literature review on AXS Vecta is also provided. In our series, 9 thrombectomies were performed (Vecta 71: 2 M1, 5 M2 occlusions; Vecta 74: 1 M1 and 1 ICA-terminus occlusion). The AXS Vecta was successfully delivered to the target site in all cases. In 7 of 9 cases, the catheter was delivered over a Tenzing 7 delivery catheter (Route 92 Medical, San Mateo, CA, USA). For 2 of 9 combination approach cases, Vecta was delivered using the stent-retriever wire as a rail. The median improvement in NIHSS score during hospitalization was 9 (IQR 5–12). Successful mTICI 2C or 3 recanalization was achieved in 8 of 9 (89%) patients after a median 2 (IQR 1–2) passes. Our median groin-to-reperfusion time was 23 (IQR 12.5–32) minutes, with no procedural complications. Two previous clinical studies of a total of 29 patients treated with Vecta 71 reported successful mTICI 2b–3 recanalization in 89–90% of cases. The Median groin-to-reperfusion time was 30 minutes. Complications were seen in 2 of 29 (6.9%) cases (vessel perforation and/or intracerebral hemorrhage). These data support the efficacy, deliverability, and safety of AXS Vecta for mechanical thrombectomy. |
format | Online Article Text |
id | pubmed-9986352 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Korean Society of Interventional Neuroradiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-99863522023-03-07 AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review Settecase, Fabio Kim, Warren T. English, Joey D. Neurointervention Case Series Aspiration catheters are widely used for thrombectomy either alone or in combination with a stent-retriever, with a distal inner diameter and trackability keys to their success. In an illustrative case series, we report our clinical experience with AXS Vecta (Stryker Neurovascular, Fremont, CA, USA), available in both 0.071-inch and 0.074-inch distal inner diameters, including the first 2 Vecta 74 cases reported. A literature review on AXS Vecta is also provided. In our series, 9 thrombectomies were performed (Vecta 71: 2 M1, 5 M2 occlusions; Vecta 74: 1 M1 and 1 ICA-terminus occlusion). The AXS Vecta was successfully delivered to the target site in all cases. In 7 of 9 cases, the catheter was delivered over a Tenzing 7 delivery catheter (Route 92 Medical, San Mateo, CA, USA). For 2 of 9 combination approach cases, Vecta was delivered using the stent-retriever wire as a rail. The median improvement in NIHSS score during hospitalization was 9 (IQR 5–12). Successful mTICI 2C or 3 recanalization was achieved in 8 of 9 (89%) patients after a median 2 (IQR 1–2) passes. Our median groin-to-reperfusion time was 23 (IQR 12.5–32) minutes, with no procedural complications. Two previous clinical studies of a total of 29 patients treated with Vecta 71 reported successful mTICI 2b–3 recanalization in 89–90% of cases. The Median groin-to-reperfusion time was 30 minutes. Complications were seen in 2 of 29 (6.9%) cases (vessel perforation and/or intracerebral hemorrhage). These data support the efficacy, deliverability, and safety of AXS Vecta for mechanical thrombectomy. Korean Society of Interventional Neuroradiology 2023-03 2022-11-04 /pmc/articles/PMC9986352/ /pubmed/36328761 http://dx.doi.org/10.5469/neuroint.2022.00283 Text en Copyright © 2023 Korean Society of Interventional Neuroradiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Series Settecase, Fabio Kim, Warren T. English, Joey D. AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title | AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title_full | AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title_fullStr | AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title_full_unstemmed | AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title_short | AXS Vecta 0.071–0.074 Inch Aspiration Catheters for Mechanical Thrombectomy: Case Series and Literature Review |
title_sort | axs vecta 0.071–0.074 inch aspiration catheters for mechanical thrombectomy: case series and literature review |
topic | Case Series |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9986352/ https://www.ncbi.nlm.nih.gov/pubmed/36328761 http://dx.doi.org/10.5469/neuroint.2022.00283 |
work_keys_str_mv | AT settecasefabio axsvecta00710074inchaspirationcathetersformechanicalthrombectomycaseseriesandliteraturereview AT kimwarrent axsvecta00710074inchaspirationcathetersformechanicalthrombectomycaseseriesandliteraturereview AT englishjoeyd axsvecta00710074inchaspirationcathetersformechanicalthrombectomycaseseriesandliteraturereview |