Cargando…
An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis
BACKGROUND: Recent data regarding the comparison of implantable cardioverter-defibrillator (ICD) therapy and optimal medical treatment in patients with non-ischemic cardiomyopathy has indicated no mortality benefit as a result of ICD therapy. Although the recommendations for ICD implantation did not...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9987540/ https://www.ncbi.nlm.nih.gov/pubmed/33843044 http://dx.doi.org/10.5603/CJ.2021.0041 |
_version_ | 1784901402959544320 |
---|---|
author | Wasiak, Michał Tajstra, Mateusz Kosior, Dariusz Gąsior, Mariusz |
author_facet | Wasiak, Michał Tajstra, Mateusz Kosior, Dariusz Gąsior, Mariusz |
author_sort | Wasiak, Michał |
collection | PubMed |
description | BACKGROUND: Recent data regarding the comparison of implantable cardioverter-defibrillator (ICD) therapy and optimal medical treatment in patients with non-ischemic cardiomyopathy has indicated no mortality benefit as a result of ICD therapy. Although the recommendations for ICD implantation did not change, it is worth noting that these findings significantly affected the daily practice of ICD implantation in Europe. METHODS: To assess the effect of ICD implantation in comparison to pharmacotherapy in the non-ischemic cardiomyopathy heart failure population through a systematic review and meta-analysis of the available carefully designed prospective randomized controlled trials. Only prospective randomized controlled trials comparing ICD implantation in primary prevention vs. optimal pharmacological therapy or placebo and reporting mortality results were included in the meta-analysis. The authors have chosen to include the following trials: CAT, AMIOVIRT, DEFINITE, and DANISH. RESULTS: A meta-analysis of pooled hazard ratios (HR) from all trials conducted on a total of 1789 patients found that ICD therapy decreased all-cause mortality in comparison to optimal pharmacological treatment, with a HR of 0.48 (95% confidence interval [CI] 0.67–1.01); p = 0.06. The data from the AMIOVIRT, DANISH, and DEFINITE trials, with a total of 1677 participants, showed a significant reduction of sudden cardiac deaths as a result of ICD implantation, with a HR of 0.48 (95% CI 0.31–0.67); p < 0.001. CONCLUSIONS: In comparison with optimal medical treatment, ICD implantation in patients with heart failure improves the long-term prognosis in terms of sudden cardiac death, with a strong tendency towards all-cause mortality reduction. |
format | Online Article Text |
id | pubmed-9987540 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-99875402023-03-07 An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis Wasiak, Michał Tajstra, Mateusz Kosior, Dariusz Gąsior, Mariusz Cardiol J Clinical Cardiology BACKGROUND: Recent data regarding the comparison of implantable cardioverter-defibrillator (ICD) therapy and optimal medical treatment in patients with non-ischemic cardiomyopathy has indicated no mortality benefit as a result of ICD therapy. Although the recommendations for ICD implantation did not change, it is worth noting that these findings significantly affected the daily practice of ICD implantation in Europe. METHODS: To assess the effect of ICD implantation in comparison to pharmacotherapy in the non-ischemic cardiomyopathy heart failure population through a systematic review and meta-analysis of the available carefully designed prospective randomized controlled trials. Only prospective randomized controlled trials comparing ICD implantation in primary prevention vs. optimal pharmacological therapy or placebo and reporting mortality results were included in the meta-analysis. The authors have chosen to include the following trials: CAT, AMIOVIRT, DEFINITE, and DANISH. RESULTS: A meta-analysis of pooled hazard ratios (HR) from all trials conducted on a total of 1789 patients found that ICD therapy decreased all-cause mortality in comparison to optimal pharmacological treatment, with a HR of 0.48 (95% confidence interval [CI] 0.67–1.01); p = 0.06. The data from the AMIOVIRT, DANISH, and DEFINITE trials, with a total of 1677 participants, showed a significant reduction of sudden cardiac deaths as a result of ICD implantation, with a HR of 0.48 (95% CI 0.31–0.67); p < 0.001. CONCLUSIONS: In comparison with optimal medical treatment, ICD implantation in patients with heart failure improves the long-term prognosis in terms of sudden cardiac death, with a strong tendency towards all-cause mortality reduction. Via Medica 2023-02-27 /pmc/articles/PMC9987540/ /pubmed/33843044 http://dx.doi.org/10.5603/CJ.2021.0041 Text en Copyright © 2023 Via Medica https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Clinical Cardiology Wasiak, Michał Tajstra, Mateusz Kosior, Dariusz Gąsior, Mariusz An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title | An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title_full | An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title_fullStr | An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title_full_unstemmed | An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title_short | An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis |
title_sort | implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: a systematic review and meta-analysis |
topic | Clinical Cardiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9987540/ https://www.ncbi.nlm.nih.gov/pubmed/33843044 http://dx.doi.org/10.5603/CJ.2021.0041 |
work_keys_str_mv | AT wasiakmichał animplantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT tajstramateusz animplantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT kosiordariusz animplantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT gasiormariusz animplantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT wasiakmichał implantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT tajstramateusz implantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT kosiordariusz implantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis AT gasiormariusz implantablecardioverterdefibrillatorforprimarypreventioninnonischemiccardiomyopathyasystematicreviewandmetaanalysis |