Cargando…
A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII
BACKGROUND: Recently, in many Asian centers, laparoscopic anatomical liver resection (LALR) using the indocyanine green (ICG) fluorescence imaging technique has been increasingly applied in resecting hepatocellular carcinoma, even in colorectal liver metastases. However, LALR techniques have not bee...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9987585/ https://www.ncbi.nlm.nih.gov/pubmed/36890822 http://dx.doi.org/10.3389/fonc.2023.1138068 |
_version_ | 1784901410301673472 |
---|---|
author | Jiang, Zedong Zhou, Bo Zheng, Xiang Li, Guogang Gao, Zhenzhen Tian, Yang Shao, Chunlong Xu, Shaoyan Yan, Sheng |
author_facet | Jiang, Zedong Zhou, Bo Zheng, Xiang Li, Guogang Gao, Zhenzhen Tian, Yang Shao, Chunlong Xu, Shaoyan Yan, Sheng |
author_sort | Jiang, Zedong |
collection | PubMed |
description | BACKGROUND: Recently, in many Asian centers, laparoscopic anatomical liver resection (LALR) using the indocyanine green (ICG) fluorescence imaging technique has been increasingly applied in resecting hepatocellular carcinoma, even in colorectal liver metastases. However, LALR techniques have not been fully standardized, especially in right superior segments. Due to the anatomical position, prevailing positive staining using a PTCD (percutaneous transhepatic cholangial drainage) needle was superior to negative staining in right superior segments hepatectomy, while it was difficult to manipulate. Herein, we design a novel method of ICG-positive staining for LALR of right superior segments. METHODS: Between April 2021 and October 2022, we retrospectively studied patients in our institute who underwent LALR of right superior segments using a novel method of ICG-positive staining, which comprised a customized puncture needle and an adaptor. Compared to the PTCD needle, the customized needle was not limited by the abdominal wall and could be punctured from the liver dorsal surface, which was more flexible to manipulate. The adapter was attached to the guide hole of the laparoscopic ultrasound (LUS) probe to ensure the precise puncture path of the needle. Guided by preoperative three-dimensional (3D) simulation and intraoperative laparoscopic ultrasound imaging, we punctured the transhepatic needle into the target portal vein through the adaptor and then slowly injected 5-10 ml of 0.025 mg/ml ICG solution into the vessel. LALR can be guided by the demarcation line under fluorescence imaging after injection. Demographic, procedural and postoperative data were collected and analyzed. RESULTS: In this study, 21 patients underwent LALR of the right superior segments with ICG fluorescence-positive staining, and the procedures had a success rate of 71.4%. The average staining time was 13.0 ± 6.4 min, the operative time was 230.4 ± 71.7 min, R0 resection was 100%, the postoperative hospital stay was 7.1 ± 2.4 days, and no severe puncture complications occurred. CONCLUSIONS: The novel customized puncture needle approach seems to be feasible and safe for ICG-positive staining in LALR of right superior segments, with a high success rate and a short staining time. |
format | Online Article Text |
id | pubmed-9987585 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99875852023-03-07 A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII Jiang, Zedong Zhou, Bo Zheng, Xiang Li, Guogang Gao, Zhenzhen Tian, Yang Shao, Chunlong Xu, Shaoyan Yan, Sheng Front Oncol Oncology BACKGROUND: Recently, in many Asian centers, laparoscopic anatomical liver resection (LALR) using the indocyanine green (ICG) fluorescence imaging technique has been increasingly applied in resecting hepatocellular carcinoma, even in colorectal liver metastases. However, LALR techniques have not been fully standardized, especially in right superior segments. Due to the anatomical position, prevailing positive staining using a PTCD (percutaneous transhepatic cholangial drainage) needle was superior to negative staining in right superior segments hepatectomy, while it was difficult to manipulate. Herein, we design a novel method of ICG-positive staining for LALR of right superior segments. METHODS: Between April 2021 and October 2022, we retrospectively studied patients in our institute who underwent LALR of right superior segments using a novel method of ICG-positive staining, which comprised a customized puncture needle and an adaptor. Compared to the PTCD needle, the customized needle was not limited by the abdominal wall and could be punctured from the liver dorsal surface, which was more flexible to manipulate. The adapter was attached to the guide hole of the laparoscopic ultrasound (LUS) probe to ensure the precise puncture path of the needle. Guided by preoperative three-dimensional (3D) simulation and intraoperative laparoscopic ultrasound imaging, we punctured the transhepatic needle into the target portal vein through the adaptor and then slowly injected 5-10 ml of 0.025 mg/ml ICG solution into the vessel. LALR can be guided by the demarcation line under fluorescence imaging after injection. Demographic, procedural and postoperative data were collected and analyzed. RESULTS: In this study, 21 patients underwent LALR of the right superior segments with ICG fluorescence-positive staining, and the procedures had a success rate of 71.4%. The average staining time was 13.0 ± 6.4 min, the operative time was 230.4 ± 71.7 min, R0 resection was 100%, the postoperative hospital stay was 7.1 ± 2.4 days, and no severe puncture complications occurred. CONCLUSIONS: The novel customized puncture needle approach seems to be feasible and safe for ICG-positive staining in LALR of right superior segments, with a high success rate and a short staining time. Frontiers Media S.A. 2023-02-20 /pmc/articles/PMC9987585/ /pubmed/36890822 http://dx.doi.org/10.3389/fonc.2023.1138068 Text en Copyright © 2023 Jiang, Zhou, Zheng, Li, Gao, Tian, Shao, Xu and Yan https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Jiang, Zedong Zhou, Bo Zheng, Xiang Li, Guogang Gao, Zhenzhen Tian, Yang Shao, Chunlong Xu, Shaoyan Yan, Sheng A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title | A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title_full | A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title_fullStr | A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title_full_unstemmed | A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title_short | A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII |
title_sort | novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments vii and viii |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9987585/ https://www.ncbi.nlm.nih.gov/pubmed/36890822 http://dx.doi.org/10.3389/fonc.2023.1138068 |
work_keys_str_mv | AT jiangzedong anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT zhoubo anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT zhengxiang anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT liguogang anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT gaozhenzhen anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT tianyang anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT shaochunlong anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT xushaoyan anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT yansheng anovelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT jiangzedong novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT zhoubo novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT zhengxiang novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT liguogang novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT gaozhenzhen novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT tianyang novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT shaochunlong novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT xushaoyan novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii AT yansheng novelmethodofultrasoundguidedpositivestainingusingindocyaninegreenfluorescenceinlaparoscopicanatomicalliverresectionofsegmentsviiandviii |