Cargando…
Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis
BACKGROUND: Bone marrow stimulation (BMS) has been considered a well-established method for treating knee and ankle osteochondral lesions. Some studies have also shown that BMS can promote healing of the repaired tendon and enhance biomechanical properties during rotator cuff repair. Our purpose was...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989271/ https://www.ncbi.nlm.nih.gov/pubmed/36896263 http://dx.doi.org/10.3389/fsurg.2023.1047483 |
_version_ | 1784901734485721088 |
---|---|
author | Zhang, Lei Zhu, Yanlin Xu, Tianhao Fu, Weili |
author_facet | Zhang, Lei Zhu, Yanlin Xu, Tianhao Fu, Weili |
author_sort | Zhang, Lei |
collection | PubMed |
description | BACKGROUND: Bone marrow stimulation (BMS) has been considered a well-established method for treating knee and ankle osteochondral lesions. Some studies have also shown that BMS can promote healing of the repaired tendon and enhance biomechanical properties during rotator cuff repair. Our purpose was to compare the clinical outcomes of arthroscopic repair rotator cuff (ARCR) with and without BMS. METHODS: A systematic review with meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). PubMed, Embase, Web of Science, Google scholar, ScienceDirect, and the Cochrane Library were searched from inception to March 20, 2022. Data on retear rates, shoulder functional outcomes, visual analog score and range of motion were pooled and analyzed. Dichotomous variables were presented as odds ratios (OR), and continuous variables were presented as mean differences (MD). Meta-analyses were conducted with Review Manager 5.3. RESULTS: Eight studies involving 674 patients were included, with mean follow-up period ranging from 12 to 36.8 months. Compared to ARCR alone, the intraoperative combination of the BMS resulted in lower retear rates (P < 0.0001), but showed similar results in Constant score (P = 0.10), University of California at Los Angeles (UCLA) score (P = 0.57), American Shoulder and Elbow Surgeons (ASES) score (P = 0.23), Disabilities of the Arm, Shoulder and Hand (DASH) score (P = 0.31), VAS (visual analog score) score (P = 0.34), and range of motion (ROM) (forward flexion, P = 0.42; external rotation, P = 0.21). After sensitivity analyses and subgroup analyses, no significant changes in statistical results were observed. CONCLUSION: Compared to ARCR alone, the combination of intraoperative BMS can significantly reduce the retear rates, but showed similar short-term results in functional outcomes, ROM and pain. Better clinical outcomes are anticipated in the BMS group by improving structural integrity during long-term follow-up. Currently, BMS may be a viable option in ARCR based on its straightforward and cost-effective advantages. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/prospero/, identifier: CRD42022323379. |
format | Online Article Text |
id | pubmed-9989271 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99892712023-03-08 Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis Zhang, Lei Zhu, Yanlin Xu, Tianhao Fu, Weili Front Surg Surgery BACKGROUND: Bone marrow stimulation (BMS) has been considered a well-established method for treating knee and ankle osteochondral lesions. Some studies have also shown that BMS can promote healing of the repaired tendon and enhance biomechanical properties during rotator cuff repair. Our purpose was to compare the clinical outcomes of arthroscopic repair rotator cuff (ARCR) with and without BMS. METHODS: A systematic review with meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). PubMed, Embase, Web of Science, Google scholar, ScienceDirect, and the Cochrane Library were searched from inception to March 20, 2022. Data on retear rates, shoulder functional outcomes, visual analog score and range of motion were pooled and analyzed. Dichotomous variables were presented as odds ratios (OR), and continuous variables were presented as mean differences (MD). Meta-analyses were conducted with Review Manager 5.3. RESULTS: Eight studies involving 674 patients were included, with mean follow-up period ranging from 12 to 36.8 months. Compared to ARCR alone, the intraoperative combination of the BMS resulted in lower retear rates (P < 0.0001), but showed similar results in Constant score (P = 0.10), University of California at Los Angeles (UCLA) score (P = 0.57), American Shoulder and Elbow Surgeons (ASES) score (P = 0.23), Disabilities of the Arm, Shoulder and Hand (DASH) score (P = 0.31), VAS (visual analog score) score (P = 0.34), and range of motion (ROM) (forward flexion, P = 0.42; external rotation, P = 0.21). After sensitivity analyses and subgroup analyses, no significant changes in statistical results were observed. CONCLUSION: Compared to ARCR alone, the combination of intraoperative BMS can significantly reduce the retear rates, but showed similar short-term results in functional outcomes, ROM and pain. Better clinical outcomes are anticipated in the BMS group by improving structural integrity during long-term follow-up. Currently, BMS may be a viable option in ARCR based on its straightforward and cost-effective advantages. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/prospero/, identifier: CRD42022323379. Frontiers Media S.A. 2023-02-21 /pmc/articles/PMC9989271/ /pubmed/36896263 http://dx.doi.org/10.3389/fsurg.2023.1047483 Text en © 2023 Zhang, Zhu, Xu and Fu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Zhang, Lei Zhu, Yanlin Xu, Tianhao Fu, Weili Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title | Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title_full | Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title_fullStr | Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title_full_unstemmed | Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title_short | Bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: A systematic review and meta-analysis |
title_sort | bone marrow stimulation in arthroscopic rotator cuff repair is a cost-effective and straightforward technique to reduce retear rates: a systematic review and meta-analysis |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989271/ https://www.ncbi.nlm.nih.gov/pubmed/36896263 http://dx.doi.org/10.3389/fsurg.2023.1047483 |
work_keys_str_mv | AT zhanglei bonemarrowstimulationinarthroscopicrotatorcuffrepairisacosteffectiveandstraightforwardtechniquetoreduceretearratesasystematicreviewandmetaanalysis AT zhuyanlin bonemarrowstimulationinarthroscopicrotatorcuffrepairisacosteffectiveandstraightforwardtechniquetoreduceretearratesasystematicreviewandmetaanalysis AT xutianhao bonemarrowstimulationinarthroscopicrotatorcuffrepairisacosteffectiveandstraightforwardtechniquetoreduceretearratesasystematicreviewandmetaanalysis AT fuweili bonemarrowstimulationinarthroscopicrotatorcuffrepairisacosteffectiveandstraightforwardtechniquetoreduceretearratesasystematicreviewandmetaanalysis |