Cargando…

Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique

BACKGROUND: In the absence of effective antiviral drugs or vaccines, early and accurate detection of SARS-CoV-2 infection is essential to the COVID-19 pandemic. This study developed and evaluated a novel rapid One-Step LAMP assay to directly detect the SARS-CoV-2 RNA from nasopharyngeal (NP) swab sa...

Descripción completa

Detalles Bibliográficos
Autores principales: Khanizadeh, Sayyad, Malekshahi, Asra, Hanifehpour, Hooman, Birjandi, Mehdi, Fallahi, Shirzad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989590/
https://www.ncbi.nlm.nih.gov/pubmed/36882699
http://dx.doi.org/10.1186/s12866-023-02806-z
_version_ 1784901800538669056
author Khanizadeh, Sayyad
Malekshahi, Asra
Hanifehpour, Hooman
Birjandi, Mehdi
Fallahi, Shirzad
author_facet Khanizadeh, Sayyad
Malekshahi, Asra
Hanifehpour, Hooman
Birjandi, Mehdi
Fallahi, Shirzad
author_sort Khanizadeh, Sayyad
collection PubMed
description BACKGROUND: In the absence of effective antiviral drugs or vaccines, early and accurate detection of SARS-CoV-2 infection is essential to the COVID-19 pandemic. This study developed and evaluated a novel rapid One-Step LAMP assay to directly detect the SARS-CoV-2 RNA from nasopharyngeal (NP) swab samples of patients with suspected SARS-CoV-2 infection living in deprived areas in comparison to One-Step Real-time PCR. METHODS: Two hundred fifty-four NP swab samples from patients suspected of COVID-19 infection living in deprived western areas of Iran were tested by TaqMan One-Step RT-qPCR and fast One-Step LAMP assays. Tenfold serial dilutions of SARS-CoV-2 RNA standard strain where the viral copy number in each dilution was previously determined using the qPCR and various templates were used to investigate the analytical sensitivity and specificity of the One-Step LAMP assay in triplicate. Also, the efficacy and reliability of the method compared to TaqMan One-Step RT-qPCR were evaluated using SARS-CoV-2 positive and negative clinical samples. RESULTS: The results of the One-Step RT-qPCR and One-Step LAMP tests were positive in 131 (51.6%) and 127 (50%) participants, respectively. Based on Cohen’s kappa coefficient (κ), the agreement between the two tests was 97%, which was statistically significant (P < 0.001). The detection limit for the One-Step LAMP assay was 1 × 10(1) copies of standard SARS-CoV-2 RNA per reaction in less than an hour in triplicates. Negative results in all samples with non-SARS-CoV-2 templates represent 100% specificity. CONCLUSIONS: The results showed that the One-Step LAMP assay is an efficient consistent technique for detecting SARS-CoV-2 among suspected individuals due to its simplicity, speed, low cost, sensitivity, and specificity. Therefore, it has great potential as a useful diagnostic tool for disease epidemic control, timely treatment, and public health protection, especially in poor and underdeveloped countries. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12866-023-02806-z.
format Online
Article
Text
id pubmed-9989590
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-99895902023-03-07 Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique Khanizadeh, Sayyad Malekshahi, Asra Hanifehpour, Hooman Birjandi, Mehdi Fallahi, Shirzad BMC Microbiol Research BACKGROUND: In the absence of effective antiviral drugs or vaccines, early and accurate detection of SARS-CoV-2 infection is essential to the COVID-19 pandemic. This study developed and evaluated a novel rapid One-Step LAMP assay to directly detect the SARS-CoV-2 RNA from nasopharyngeal (NP) swab samples of patients with suspected SARS-CoV-2 infection living in deprived areas in comparison to One-Step Real-time PCR. METHODS: Two hundred fifty-four NP swab samples from patients suspected of COVID-19 infection living in deprived western areas of Iran were tested by TaqMan One-Step RT-qPCR and fast One-Step LAMP assays. Tenfold serial dilutions of SARS-CoV-2 RNA standard strain where the viral copy number in each dilution was previously determined using the qPCR and various templates were used to investigate the analytical sensitivity and specificity of the One-Step LAMP assay in triplicate. Also, the efficacy and reliability of the method compared to TaqMan One-Step RT-qPCR were evaluated using SARS-CoV-2 positive and negative clinical samples. RESULTS: The results of the One-Step RT-qPCR and One-Step LAMP tests were positive in 131 (51.6%) and 127 (50%) participants, respectively. Based on Cohen’s kappa coefficient (κ), the agreement between the two tests was 97%, which was statistically significant (P < 0.001). The detection limit for the One-Step LAMP assay was 1 × 10(1) copies of standard SARS-CoV-2 RNA per reaction in less than an hour in triplicates. Negative results in all samples with non-SARS-CoV-2 templates represent 100% specificity. CONCLUSIONS: The results showed that the One-Step LAMP assay is an efficient consistent technique for detecting SARS-CoV-2 among suspected individuals due to its simplicity, speed, low cost, sensitivity, and specificity. Therefore, it has great potential as a useful diagnostic tool for disease epidemic control, timely treatment, and public health protection, especially in poor and underdeveloped countries. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12866-023-02806-z. BioMed Central 2023-03-07 /pmc/articles/PMC9989590/ /pubmed/36882699 http://dx.doi.org/10.1186/s12866-023-02806-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Khanizadeh, Sayyad
Malekshahi, Asra
Hanifehpour, Hooman
Birjandi, Mehdi
Fallahi, Shirzad
Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title_full Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title_fullStr Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title_full_unstemmed Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title_short Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique
title_sort rapid, sensitive, and specific detection of sars-cov-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step lamp) technique
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989590/
https://www.ncbi.nlm.nih.gov/pubmed/36882699
http://dx.doi.org/10.1186/s12866-023-02806-z
work_keys_str_mv AT khanizadehsayyad rapidsensitiveandspecificdetectionofsarscov2innasopharyngealswabsamplesofsuspectedpatientsusinganovelonesteploopmediatedisothermalamplificationonesteplamptechnique
AT malekshahiasra rapidsensitiveandspecificdetectionofsarscov2innasopharyngealswabsamplesofsuspectedpatientsusinganovelonesteploopmediatedisothermalamplificationonesteplamptechnique
AT hanifehpourhooman rapidsensitiveandspecificdetectionofsarscov2innasopharyngealswabsamplesofsuspectedpatientsusinganovelonesteploopmediatedisothermalamplificationonesteplamptechnique
AT birjandimehdi rapidsensitiveandspecificdetectionofsarscov2innasopharyngealswabsamplesofsuspectedpatientsusinganovelonesteploopmediatedisothermalamplificationonesteplamptechnique
AT fallahishirzad rapidsensitiveandspecificdetectionofsarscov2innasopharyngealswabsamplesofsuspectedpatientsusinganovelonesteploopmediatedisothermalamplificationonesteplamptechnique