Cargando…
ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill
Hemodynamic assessment along with continuous monitoring and appropriate therapy forms an integral part of management of critically ill patients with acute circulatory failure. In India, the infrastructure in ICUs varies from very basic facilities in smaller towns and semi-urban areas, to world-class...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Jaypee Brothers Medical Publishers
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989872/ https://www.ncbi.nlm.nih.gov/pubmed/36896359 http://dx.doi.org/10.5005/jp-journals-10071-24301 |
_version_ | 1784901844093370368 |
---|---|
author | Kulkarni, Atul Prabhakar Govil, Deepak Samavedam, Srinivas Srinivasan, Shrikanth Ramasubban, Suresh Venkataraman, Ramesh Pichamuthu, Kishore Jog, Sameer Arvind Divatia, Jigeeshu V Myatra, Sheila Nainan |
author_facet | Kulkarni, Atul Prabhakar Govil, Deepak Samavedam, Srinivas Srinivasan, Shrikanth Ramasubban, Suresh Venkataraman, Ramesh Pichamuthu, Kishore Jog, Sameer Arvind Divatia, Jigeeshu V Myatra, Sheila Nainan |
author_sort | Kulkarni, Atul Prabhakar |
collection | PubMed |
description | Hemodynamic assessment along with continuous monitoring and appropriate therapy forms an integral part of management of critically ill patients with acute circulatory failure. In India, the infrastructure in ICUs varies from very basic facilities in smaller towns and semi-urban areas, to world-class, cutting-edge technology in corporate hospitals, in metropolitan cities. Surveys and studies from India suggest a wide variation in clinical practices due to possible lack of awareness, expertise, high costs, and lack of availability of advanced hemodynamic monitoring devices. We, therefore, on behalf of the Indian Society of Critical Care Medicine (ISCCM), formulated these evidence-based guidelines for optimal use of various hemodynamic monitoring modalities keeping in mind the resource-limited settings and the specific needs of our patients. When enough evidence was not forthcoming, we have made recommendations after achieving consensus amongst members. Careful integration of clinical assessment and critical information obtained from laboratory data and monitoring devices should help in improving outcomes of our patients. HOW TO CITE THIS ARTICLE: Kulkarni AP, Govil D, Samavedam S, Srinivasan S, Ramasubban S, Venkataraman R, et al. ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill. Indian J Crit Care Med 2022;26(S2):S66–S76. |
format | Online Article Text |
id | pubmed-9989872 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Jaypee Brothers Medical Publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-99898722023-03-08 ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill Kulkarni, Atul Prabhakar Govil, Deepak Samavedam, Srinivas Srinivasan, Shrikanth Ramasubban, Suresh Venkataraman, Ramesh Pichamuthu, Kishore Jog, Sameer Arvind Divatia, Jigeeshu V Myatra, Sheila Nainan Indian J Crit Care Med Guidelines Hemodynamic assessment along with continuous monitoring and appropriate therapy forms an integral part of management of critically ill patients with acute circulatory failure. In India, the infrastructure in ICUs varies from very basic facilities in smaller towns and semi-urban areas, to world-class, cutting-edge technology in corporate hospitals, in metropolitan cities. Surveys and studies from India suggest a wide variation in clinical practices due to possible lack of awareness, expertise, high costs, and lack of availability of advanced hemodynamic monitoring devices. We, therefore, on behalf of the Indian Society of Critical Care Medicine (ISCCM), formulated these evidence-based guidelines for optimal use of various hemodynamic monitoring modalities keeping in mind the resource-limited settings and the specific needs of our patients. When enough evidence was not forthcoming, we have made recommendations after achieving consensus amongst members. Careful integration of clinical assessment and critical information obtained from laboratory data and monitoring devices should help in improving outcomes of our patients. HOW TO CITE THIS ARTICLE: Kulkarni AP, Govil D, Samavedam S, Srinivasan S, Ramasubban S, Venkataraman R, et al. ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill. Indian J Crit Care Med 2022;26(S2):S66–S76. Jaypee Brothers Medical Publishers 2022-10 /pmc/articles/PMC9989872/ /pubmed/36896359 http://dx.doi.org/10.5005/jp-journals-10071-24301 Text en Copyright © 2022; Jaypee Brothers Medical Publishers (P) Ltd. https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Guidelines Kulkarni, Atul Prabhakar Govil, Deepak Samavedam, Srinivas Srinivasan, Shrikanth Ramasubban, Suresh Venkataraman, Ramesh Pichamuthu, Kishore Jog, Sameer Arvind Divatia, Jigeeshu V Myatra, Sheila Nainan ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title | ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title_full | ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title_fullStr | ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title_full_unstemmed | ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title_short | ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill |
title_sort | isccm guidelines for hemodynamic monitoring in the critically ill |
topic | Guidelines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9989872/ https://www.ncbi.nlm.nih.gov/pubmed/36896359 http://dx.doi.org/10.5005/jp-journals-10071-24301 |
work_keys_str_mv | AT kulkarniatulprabhakar isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT govildeepak isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT samavedamsrinivas isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT srinivasanshrikanth isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT ramasubbansuresh isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT venkataramanramesh isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT pichamuthukishore isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT jogsameerarvind isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT divatiajigeeshuv isccmguidelinesforhemodynamicmonitoringinthecriticallyill AT myatrasheilanainan isccmguidelinesforhemodynamicmonitoringinthecriticallyill |