Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure
BACKGROUND: Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two mo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990537/ https://www.ncbi.nlm.nih.gov/pubmed/36896229 http://dx.doi.org/10.14740/cr1447 |
_version_ | 1784901953520664576 |
---|---|
author | Aggarwal, Ankita Khan, Zubair Machado, Christian Zughaib, Marcel |
author_facet | Aggarwal, Ankita Khan, Zubair Machado, Christian Zughaib, Marcel |
author_sort | Aggarwal, Ankita |
collection | PubMed |
description | BACKGROUND: Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two modalities in patients who simultaneously had both the devices. METHODS: Patients with history of New York Heart Association class III systolic HF with a pre-implanted intracardiac defibrillator (ICD) capable of monitoring TI and pre-implanted CardioMEMs™ remote HF monitoring device were included. Hemodynamic data including TI and PAPs were measured at baseline and then weekly. Weekly percentage change was then calculated as: Weekly percentage change = (week 2 - week1)/week 1 × 100. Variability between the methods was expressed by Bland-Altman analysis. Significance was determined as a P-value < 0.05. RESULTS: Nine patients met the inclusion criteria. There was no significant correlation between the assessed weekly percentage changes in pulmonary artery diastolic pressure (PAdP) and TI measurements (r = -0.180, P = 0.065). Using Bland-Altman analytic methods, both methods had no significant difference in agreement (0.011±0.094%, P = 0.215). With the linear regression model applied for Bland-Altman analysis, the two methods appeared to have proportional bias without agreement (unstandardized beta-coefficient of 1.91, t 22.9, P ≤ 0.001). CONCLUSION: Our study demonstrated that variations exist between measurement of PAdP and TI; however, there is no significant correlation between weekly variations between them. |
format | Online Article Text |
id | pubmed-9990537 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-99905372023-03-08 Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure Aggarwal, Ankita Khan, Zubair Machado, Christian Zughaib, Marcel Cardiol Res Original Article BACKGROUND: Heart failure (HF) readmission continues to be a major health problem. Monitoring pulmonary artery pressure (PAP) and thoracic impedance (TI) are the two modalities utilized for early identification of decompensation in HF patients. We aimed to assess the correlation between these two modalities in patients who simultaneously had both the devices. METHODS: Patients with history of New York Heart Association class III systolic HF with a pre-implanted intracardiac defibrillator (ICD) capable of monitoring TI and pre-implanted CardioMEMs™ remote HF monitoring device were included. Hemodynamic data including TI and PAPs were measured at baseline and then weekly. Weekly percentage change was then calculated as: Weekly percentage change = (week 2 - week1)/week 1 × 100. Variability between the methods was expressed by Bland-Altman analysis. Significance was determined as a P-value < 0.05. RESULTS: Nine patients met the inclusion criteria. There was no significant correlation between the assessed weekly percentage changes in pulmonary artery diastolic pressure (PAdP) and TI measurements (r = -0.180, P = 0.065). Using Bland-Altman analytic methods, both methods had no significant difference in agreement (0.011±0.094%, P = 0.215). With the linear regression model applied for Bland-Altman analysis, the two methods appeared to have proportional bias without agreement (unstandardized beta-coefficient of 1.91, t 22.9, P ≤ 0.001). CONCLUSION: Our study demonstrated that variations exist between measurement of PAdP and TI; however, there is no significant correlation between weekly variations between them. Elmer Press 2023-02 2023-02-25 /pmc/articles/PMC9990537/ /pubmed/36896229 http://dx.doi.org/10.14740/cr1447 Text en Copyright 2023, Aggarwal et al. https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Aggarwal, Ankita Khan, Zubair Machado, Christian Zughaib, Marcel Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title | Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title_full | Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title_fullStr | Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title_full_unstemmed | Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title_short | Assessing Correlation Between Thoracic Impedance and Remotely Monitored Pulmonary Artery Pressure in Chronic Systolic Heart Failure |
title_sort | assessing correlation between thoracic impedance and remotely monitored pulmonary artery pressure in chronic systolic heart failure |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990537/ https://www.ncbi.nlm.nih.gov/pubmed/36896229 http://dx.doi.org/10.14740/cr1447 |
work_keys_str_mv | AT aggarwalankita assessingcorrelationbetweenthoracicimpedanceandremotelymonitoredpulmonaryarterypressureinchronicsystolicheartfailure AT khanzubair assessingcorrelationbetweenthoracicimpedanceandremotelymonitoredpulmonaryarterypressureinchronicsystolicheartfailure AT machadochristian assessingcorrelationbetweenthoracicimpedanceandremotelymonitoredpulmonaryarterypressureinchronicsystolicheartfailure AT zughaibmarcel assessingcorrelationbetweenthoracicimpedanceandremotelymonitoredpulmonaryarterypressureinchronicsystolicheartfailure |