Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device

BACKGROUND: Cardiac arrhythmias are significantly associated with poor outcomes in coronavirus disease 2019 (COVID-19) patients. Microvolt T-wave alternans (TWA) can be automatically quantified and has been recognized as a representation of repolarization heterogeneity and linked to arrhythmogenesis...

Descripción completa

Detalles Bibliográficos
Autores principales: Tondas, Alexander Edo, Munawar, Dian Andina, Marcantoni, Ilaria, Liberty, Iche Andriyani, Mulawarman, Rido, Hadi, Muhammad, Trifitriana, Monica, Indrajaya, Taufik, Yamin, Muhammad, Irfannuddin, Irfannuddin, Burattini, Laura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990541/
https://www.ncbi.nlm.nih.gov/pubmed/36896221
http://dx.doi.org/10.14740/cr1458
_version_ 1784901954513666048
author Tondas, Alexander Edo
Munawar, Dian Andina
Marcantoni, Ilaria
Liberty, Iche Andriyani
Mulawarman, Rido
Hadi, Muhammad
Trifitriana, Monica
Indrajaya, Taufik
Yamin, Muhammad
Irfannuddin, Irfannuddin
Burattini, Laura
author_facet Tondas, Alexander Edo
Munawar, Dian Andina
Marcantoni, Ilaria
Liberty, Iche Andriyani
Mulawarman, Rido
Hadi, Muhammad
Trifitriana, Monica
Indrajaya, Taufik
Yamin, Muhammad
Irfannuddin, Irfannuddin
Burattini, Laura
author_sort Tondas, Alexander Edo
collection PubMed
description BACKGROUND: Cardiac arrhythmias are significantly associated with poor outcomes in coronavirus disease 2019 (COVID-19) patients. Microvolt T-wave alternans (TWA) can be automatically quantified and has been recognized as a representation of repolarization heterogeneity and linked to arrhythmogenesis in various cardiovascular diseases. This study aimed to explore the correlation between microvolt TWA and COVID-19 pathology. METHODS: Patients suspected of COVID-19 in Mohammad Hoesin General Hospital were consecutively evaluated using Alivecor(®) Kardiamobile 6L™ portable electrocardiogram (ECG) device. Severe COVID-19 patients or those who are unable to cooperate in active ECG self-recording were excluded from the study. TWA was detected and its amplitude was quantified using the novel enhanced adaptive match filter (EAMF) method. RESULTS: A total of 175 patients, 114 COVID-19 patients (polymerase chain reaction (PCR)-positive group), and 61 non-COVID-19 patients (PCR-negative group) were enrolled in the study. PCR-positive group was subdivided according to the severity of COVID-19 pathology into mild and moderate severity subgroups. Baseline TWA levels were similar between both groups during admission (42.47 ± 26.52 µV vs. 44.72 ± 38.21 µV), but higher TWA levels were observed during discharge in the PCR-positive compared to the PCR-negative group (53.45 ± 34.42 µV vs. 25.15 ± 17.64 µV, P = 0.03). The correlation between PCR-positive result in COVID-19 and TWA value was significant, after adjustment of other confounding variables (R(2) = 0.081, P = 0.030). There was no significant difference in TWA levels between mild and moderate severity subgroups in patients with COVID-19, both during admission (44.29 ± 27.14 µV vs. 36.75 ± 24.46 µV, P = 0.34) and discharge (49.47 ± 33.62 µV vs. 61.09 ± 35.99 µV, P = 0.33). CONCLUSIONS: Higher TWA values can be observed on follow-up ECG obtained during discharge in the PCR-positive COVID-19 patients.
format Online
Article
Text
id pubmed-9990541
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-99905412023-03-08 Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device Tondas, Alexander Edo Munawar, Dian Andina Marcantoni, Ilaria Liberty, Iche Andriyani Mulawarman, Rido Hadi, Muhammad Trifitriana, Monica Indrajaya, Taufik Yamin, Muhammad Irfannuddin, Irfannuddin Burattini, Laura Cardiol Res Original Article BACKGROUND: Cardiac arrhythmias are significantly associated with poor outcomes in coronavirus disease 2019 (COVID-19) patients. Microvolt T-wave alternans (TWA) can be automatically quantified and has been recognized as a representation of repolarization heterogeneity and linked to arrhythmogenesis in various cardiovascular diseases. This study aimed to explore the correlation between microvolt TWA and COVID-19 pathology. METHODS: Patients suspected of COVID-19 in Mohammad Hoesin General Hospital were consecutively evaluated using Alivecor(®) Kardiamobile 6L™ portable electrocardiogram (ECG) device. Severe COVID-19 patients or those who are unable to cooperate in active ECG self-recording were excluded from the study. TWA was detected and its amplitude was quantified using the novel enhanced adaptive match filter (EAMF) method. RESULTS: A total of 175 patients, 114 COVID-19 patients (polymerase chain reaction (PCR)-positive group), and 61 non-COVID-19 patients (PCR-negative group) were enrolled in the study. PCR-positive group was subdivided according to the severity of COVID-19 pathology into mild and moderate severity subgroups. Baseline TWA levels were similar between both groups during admission (42.47 ± 26.52 µV vs. 44.72 ± 38.21 µV), but higher TWA levels were observed during discharge in the PCR-positive compared to the PCR-negative group (53.45 ± 34.42 µV vs. 25.15 ± 17.64 µV, P = 0.03). The correlation between PCR-positive result in COVID-19 and TWA value was significant, after adjustment of other confounding variables (R(2) = 0.081, P = 0.030). There was no significant difference in TWA levels between mild and moderate severity subgroups in patients with COVID-19, both during admission (44.29 ± 27.14 µV vs. 36.75 ± 24.46 µV, P = 0.34) and discharge (49.47 ± 33.62 µV vs. 61.09 ± 35.99 µV, P = 0.33). CONCLUSIONS: Higher TWA values can be observed on follow-up ECG obtained during discharge in the PCR-positive COVID-19 patients. Elmer Press 2023-02 2023-02-25 /pmc/articles/PMC9990541/ /pubmed/36896221 http://dx.doi.org/10.14740/cr1458 Text en Copyright 2023, Tondas et al. https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Tondas, Alexander Edo
Munawar, Dian Andina
Marcantoni, Ilaria
Liberty, Iche Andriyani
Mulawarman, Rido
Hadi, Muhammad
Trifitriana, Monica
Indrajaya, Taufik
Yamin, Muhammad
Irfannuddin, Irfannuddin
Burattini, Laura
Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title_full Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title_fullStr Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title_full_unstemmed Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title_short Is T-Wave Alternans a Repolarization Abnormality Marker in COVID-19? An Investigation on the Potentialities of Portable Electrocardiogram Device
title_sort is t-wave alternans a repolarization abnormality marker in covid-19? an investigation on the potentialities of portable electrocardiogram device
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990541/
https://www.ncbi.nlm.nih.gov/pubmed/36896221
http://dx.doi.org/10.14740/cr1458
work_keys_str_mv AT tondasalexanderedo istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT munawardianandina istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT marcantoniilaria istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT libertyicheandriyani istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT mulawarmanrido istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT hadimuhammad istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT trifitrianamonica istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT indrajayataufik istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT yaminmuhammad istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT irfannuddinirfannuddin istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice
AT burattinilaura istwavealternansarepolarizationabnormalitymarkerincovid19aninvestigationonthepotentialitiesofportableelectrocardiogramdevice