Cargando…
Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial
INTRODUCTION: There is a worldwide need to enhance the capacity of audiometry testing. The objective of this study is to compare the User-operated Audiometry (UAud) system with traditional audiometry in a clinical setting, by investigating if hearing aid effectiveness based on UAud is non-inferior t...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990669/ https://www.ncbi.nlm.nih.gov/pubmed/36863737 http://dx.doi.org/10.1136/bmjopen-2022-065777 |
_version_ | 1784901983540346880 |
---|---|
author | Pedersen, Carl Christian Pedersen, Ellen Raben Laugesen, Søren Sanchez-Lopez, Raul Nielsen, Jacob Sørensen, Chris Bang Sidiras, Christos Pedersen, René Gyldenlund Schmidt, Jesper Hvass |
author_facet | Pedersen, Carl Christian Pedersen, Ellen Raben Laugesen, Søren Sanchez-Lopez, Raul Nielsen, Jacob Sørensen, Chris Bang Sidiras, Christos Pedersen, René Gyldenlund Schmidt, Jesper Hvass |
author_sort | Pedersen, Carl Christian |
collection | PubMed |
description | INTRODUCTION: There is a worldwide need to enhance the capacity of audiometry testing. The objective of this study is to compare the User-operated Audiometry (UAud) system with traditional audiometry in a clinical setting, by investigating if hearing aid effectiveness based on UAud is non-inferior to hearing aid effectiveness based on traditional audiometry, and whether thresholds obtained with the user-operated version of the Audible Contrast Threshold (ACT) test correlates to traditional measures of speech intelligibility. METHODS AND ANALYSIS: The design will be a blinded non-inferiority randomised controlled trial. 250 adults referred for hearing aid treatment will be enrolled in the study. Study participants will be tested using both traditional audiometry as well as the UAud system and they will answer the questionnaire Speech, Spatial and Qualities of Hearing Scale (SSQ12) at baseline. Participants will be randomly divided to receive hearing aids fitted based on either UAud or traditional audiometry. Three months after participants have started using their hearing aids, they will undergo a hearing in noise test with hearing aids to measure their speech-in-noise performance and answer the following questionnaires: SSQ12, the Abbreviated Profile of Hearing Aid Benefit and the International Outcome Inventory for Hearing Aids. The primary outcome is a comparison of the change in SSQ12 scores from baseline to follow-up between the two groups. Participants will undergo the user-operated ACT test of spectro-temporal modulation sensitivity as part of the UAud system. The ACT results will be compared with measures of speech intelligibility from the traditional audiometry session and follow-up measurements. ETHICS AND DISSEMINATION: The project was evaluated by the Research Ethics Committee of Southern Denmark and judged not to need approval. The findings will be submitted to an international peer-reviewed journal and presented at national and international conferences. TRIAL REGISTRATION NUMBER: NCT05043207. |
format | Online Article Text |
id | pubmed-9990669 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-99906692023-03-08 Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial Pedersen, Carl Christian Pedersen, Ellen Raben Laugesen, Søren Sanchez-Lopez, Raul Nielsen, Jacob Sørensen, Chris Bang Sidiras, Christos Pedersen, René Gyldenlund Schmidt, Jesper Hvass BMJ Open Ear, Nose and Throat/Otolaryngology INTRODUCTION: There is a worldwide need to enhance the capacity of audiometry testing. The objective of this study is to compare the User-operated Audiometry (UAud) system with traditional audiometry in a clinical setting, by investigating if hearing aid effectiveness based on UAud is non-inferior to hearing aid effectiveness based on traditional audiometry, and whether thresholds obtained with the user-operated version of the Audible Contrast Threshold (ACT) test correlates to traditional measures of speech intelligibility. METHODS AND ANALYSIS: The design will be a blinded non-inferiority randomised controlled trial. 250 adults referred for hearing aid treatment will be enrolled in the study. Study participants will be tested using both traditional audiometry as well as the UAud system and they will answer the questionnaire Speech, Spatial and Qualities of Hearing Scale (SSQ12) at baseline. Participants will be randomly divided to receive hearing aids fitted based on either UAud or traditional audiometry. Three months after participants have started using their hearing aids, they will undergo a hearing in noise test with hearing aids to measure their speech-in-noise performance and answer the following questionnaires: SSQ12, the Abbreviated Profile of Hearing Aid Benefit and the International Outcome Inventory for Hearing Aids. The primary outcome is a comparison of the change in SSQ12 scores from baseline to follow-up between the two groups. Participants will undergo the user-operated ACT test of spectro-temporal modulation sensitivity as part of the UAud system. The ACT results will be compared with measures of speech intelligibility from the traditional audiometry session and follow-up measurements. ETHICS AND DISSEMINATION: The project was evaluated by the Research Ethics Committee of Southern Denmark and judged not to need approval. The findings will be submitted to an international peer-reviewed journal and presented at national and international conferences. TRIAL REGISTRATION NUMBER: NCT05043207. BMJ Publishing Group 2023-03-02 /pmc/articles/PMC9990669/ /pubmed/36863737 http://dx.doi.org/10.1136/bmjopen-2022-065777 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Ear, Nose and Throat/Otolaryngology Pedersen, Carl Christian Pedersen, Ellen Raben Laugesen, Søren Sanchez-Lopez, Raul Nielsen, Jacob Sørensen, Chris Bang Sidiras, Christos Pedersen, René Gyldenlund Schmidt, Jesper Hvass Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title | Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title_full | Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title_fullStr | Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title_full_unstemmed | Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title_short | Comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
title_sort | comparison of hearing aid fitting effectiveness with audiograms from either user-operated or traditional audiometry in a clinical setting: a study protocol for a blinded non-inferiority randomised controlled trial |
topic | Ear, Nose and Throat/Otolaryngology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990669/ https://www.ncbi.nlm.nih.gov/pubmed/36863737 http://dx.doi.org/10.1136/bmjopen-2022-065777 |
work_keys_str_mv | AT pedersencarlchristian comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT pedersenellenraben comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT laugesensøren comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT sanchezlopezraul comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT nielsenjacob comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT sørensenchrisbang comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT sidiraschristos comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT pedersenrenegyldenlund comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial AT schmidtjesperhvass comparisonofhearingaidfittingeffectivenesswithaudiogramsfromeitheruseroperatedortraditionalaudiometryinaclinicalsettingastudyprotocolforablindednoninferiorityrandomisedcontrolledtrial |