Cargando…

Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report

BACKGROUND: Continuous-flow left ventricular assist device (CF-LVAD) technology has rapidly developed to support the failing heart refractory to standard medical treatments. Although the expected prognosis has improved dramatically, ischemic and hemorrhagic strokes are possible complications and the...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Daisuke, Koizumi, Satoshi, Umekawa, Motoyuki, Kioyofuji, Satoshi, Ando, Masahiko, Ono, Minoru, Saito, Nobuhito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Scientific Scholar 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990801/
https://www.ncbi.nlm.nih.gov/pubmed/36895216
http://dx.doi.org/10.25259/SNI_1101_2022
_version_ 1784902013315710976
author Sato, Daisuke
Koizumi, Satoshi
Umekawa, Motoyuki
Kioyofuji, Satoshi
Ando, Masahiko
Ono, Minoru
Saito, Nobuhito
author_facet Sato, Daisuke
Koizumi, Satoshi
Umekawa, Motoyuki
Kioyofuji, Satoshi
Ando, Masahiko
Ono, Minoru
Saito, Nobuhito
author_sort Sato, Daisuke
collection PubMed
description BACKGROUND: Continuous-flow left ventricular assist device (CF-LVAD) technology has rapidly developed to support the failing heart refractory to standard medical treatments. Although the expected prognosis has improved dramatically, ischemic and hemorrhagic strokes are possible complications and the leading causes of death in the CF-LVAD population. CASE DESCRIPTION: We encountered a case of an unruptured large internal carotid aneurysm in a patient with a CF-LVAD. Following a detailed discussion of his expected prognosis, the risk of aneurysm rupture, and the inherited risk of aneurysm treatment, coil embolization was performed without adverse events. The patient remained recurrence-free for 2-year postoperatively. CONCLUSION: This report illustrates the feasibility of coil embolization in a CF-LVAD recipient and emphasizes the necessity of vigilant consideration of whether to intervene in an intracranial aneurysm after CF-LVAD implantation. We confronted several challenges during the treatment: optimal endovascular technique, management of antithrombotic drugs, safe arterial access, desirable perioperative imaging modalities, and prevention of ischemic complications. This study aimed to share this experience.
format Online
Article
Text
id pubmed-9990801
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Scientific Scholar
record_format MEDLINE/PubMed
spelling pubmed-99908012023-03-08 Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report Sato, Daisuke Koizumi, Satoshi Umekawa, Motoyuki Kioyofuji, Satoshi Ando, Masahiko Ono, Minoru Saito, Nobuhito Surg Neurol Int Case Report BACKGROUND: Continuous-flow left ventricular assist device (CF-LVAD) technology has rapidly developed to support the failing heart refractory to standard medical treatments. Although the expected prognosis has improved dramatically, ischemic and hemorrhagic strokes are possible complications and the leading causes of death in the CF-LVAD population. CASE DESCRIPTION: We encountered a case of an unruptured large internal carotid aneurysm in a patient with a CF-LVAD. Following a detailed discussion of his expected prognosis, the risk of aneurysm rupture, and the inherited risk of aneurysm treatment, coil embolization was performed without adverse events. The patient remained recurrence-free for 2-year postoperatively. CONCLUSION: This report illustrates the feasibility of coil embolization in a CF-LVAD recipient and emphasizes the necessity of vigilant consideration of whether to intervene in an intracranial aneurysm after CF-LVAD implantation. We confronted several challenges during the treatment: optimal endovascular technique, management of antithrombotic drugs, safe arterial access, desirable perioperative imaging modalities, and prevention of ischemic complications. This study aimed to share this experience. Scientific Scholar 2023-01-27 /pmc/articles/PMC9990801/ /pubmed/36895216 http://dx.doi.org/10.25259/SNI_1101_2022 Text en Copyright: © 2023 Surgical Neurology International https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Sato, Daisuke
Koizumi, Satoshi
Umekawa, Motoyuki
Kioyofuji, Satoshi
Ando, Masahiko
Ono, Minoru
Saito, Nobuhito
Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title_full Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title_fullStr Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title_full_unstemmed Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title_short Controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow LVAD implanted patient: A case report
title_sort controversies and challenges of coil embolization for intracranial aneurysm in a continuous-flow lvad implanted patient: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990801/
https://www.ncbi.nlm.nih.gov/pubmed/36895216
http://dx.doi.org/10.25259/SNI_1101_2022
work_keys_str_mv AT satodaisuke controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT koizumisatoshi controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT umekawamotoyuki controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT kioyofujisatoshi controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT andomasahiko controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT onominoru controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport
AT saitonobuhito controversiesandchallengesofcoilembolizationforintracranialaneurysminacontinuousflowlvadimplantedpatientacasereport