Cargando…
Effect of Laryngoscope Blade Size on First Pass Success of Tracheal Intubation in Critically Ill Adults
Tracheal intubation (TI) is a common procedure in critical care, often performed with a Macintosh curved blade used for direct laryngoscopy (DL). Minimal evidence informs the choice between Macintosh blade sizes during TI. We hypothesized that Macintosh 4 blade would have higher first-attempt succes...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9990830/ https://www.ncbi.nlm.nih.gov/pubmed/36895888 http://dx.doi.org/10.1097/CCE.0000000000000855 |
Sumario: | Tracheal intubation (TI) is a common procedure in critical care, often performed with a Macintosh curved blade used for direct laryngoscopy (DL). Minimal evidence informs the choice between Macintosh blade sizes during TI. We hypothesized that Macintosh 4 blade would have higher first-attempt success than Macintosh 3 blade during DL. DESIGN: Retrospective analysis using a propensity score and inverse probability weighting of data from six prior multicenter randomized trials. SETTING AND PARTICIPANTS: Adult patients who underwent nonelective TI at participating emergency departments and ICUs. We compared the first-pass success of TI with DL in subjects intubated with a size 4 Macintosh blade on the first TI attempt to subjects with a size 3 Macintosh blade on the first TI attempt. MAIN RESULTS: Among 979 subjects, 592 (60.5%) had TI using DL with a Macintosh blade, of whom 362 (37%) were intubated with a size 4 blade and 222 (22.7%) with a size 3 blade. We used inverse probability weighting with a propensity score for analyzing data. We found that patients intubated with a size 4 blade had a worse (higher) Cormack-Lehane grade of glottic view than patients intubated with a size 3 blade (adjusted odds ratio [aOR], 1.458; 95% CI, 1.064–2.003; p = 0.02). Patients intubated with a size 4 blade had a lower first pass success than those with a size 3 blade (71.1% vs 81.2%; aOR, 0.566; 95% CI, 0.372–0.850; p = 0.01). CONCLUSIONS AND RELEVANCE: In critically ill adults undergoing TI using DL with a Macintosh blade, patients intubated using a size 4 blade on first attempt had a worse glottic view and a lower first pass success than patients intubated with a size 3 Macintosh blade. Further prospective studies are needed to examine the optimal approach to selecting laryngoscope blade size during TI of critically ill adults. |
---|