Cargando…
Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes
OBJECTIVE: Intermittently scanned continuous glucose monitoring (isCGM) is used for unblinded or blinded monitoring of interstitial glucose. We aimed to compare the efficacy of blinded and unblinded isCGM with the FreeStyle Libre system for glycemic control in adults with type 1 diabetes (T1D). RESE...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9992877/ https://www.ncbi.nlm.nih.gov/pubmed/36909344 http://dx.doi.org/10.3389/fendo.2023.1110845 |
_version_ | 1784902416272982016 |
---|---|
author | Guo, Lixin Li, Yuxiu Zhang, Mei Xiao, Xinhua Kuang, Hongyu Yang, Tao Jia, Xiaofan Zhang, Xianbo |
author_facet | Guo, Lixin Li, Yuxiu Zhang, Mei Xiao, Xinhua Kuang, Hongyu Yang, Tao Jia, Xiaofan Zhang, Xianbo |
author_sort | Guo, Lixin |
collection | PubMed |
description | OBJECTIVE: Intermittently scanned continuous glucose monitoring (isCGM) is used for unblinded or blinded monitoring of interstitial glucose. We aimed to compare the efficacy of blinded and unblinded isCGM with the FreeStyle Libre system for glycemic control in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: This randomized clinical trial conducted between October 2018 and September 2019 across four endocrinology practices in China included 273 adults aged ≥18 years with T1D, who were randomly divided in a 2:1 ratio into the unblinded (n = 199) or blinded isCGM group (n = 78). In the blinded group, the clinician used FreeStyle Libre Pro system for monitoring, but self-monitoring was also performed by the patients. RESULTS: Two hundred sixteen (78%) participants completed the study (152 [75%] in the unblinded and 64 [82%] in the blinded group). At 12 weeks, a significant increase in TIR (3.9-10.0 mmol/L) was only observed in the unblinded group, along with a significant decrease in hyperglycemia (>13.9 mmol/L), hypoglycemia (<3.0 mmol/L), glycemic variability. Further, the mean HbA1c reduction from baseline to 12 weeks was 0.5% in the unblinded isCGM group and 0.4% in the blinded isCGM group respectively (P < 0.001), but the significance did not remain after adjustment for between-group differences. Finally, 99.5% of the blinded isCGM values and 93.8% the of unblinded isCGM values were obtained at the final visit. CONCLUSIONS: The unblinded isCGM system was associated with benefits for glucose management, but nearly 100% of the attempted profiles were obtained successfully with the blinded isCGM system. Thus, combining real-time and retrospective data with isCGM might be the most impactful way to utilize flash glycemic monitoring devices. |
format | Online Article Text |
id | pubmed-9992877 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99928772023-03-09 Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes Guo, Lixin Li, Yuxiu Zhang, Mei Xiao, Xinhua Kuang, Hongyu Yang, Tao Jia, Xiaofan Zhang, Xianbo Front Endocrinol (Lausanne) Endocrinology OBJECTIVE: Intermittently scanned continuous glucose monitoring (isCGM) is used for unblinded or blinded monitoring of interstitial glucose. We aimed to compare the efficacy of blinded and unblinded isCGM with the FreeStyle Libre system for glycemic control in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: This randomized clinical trial conducted between October 2018 and September 2019 across four endocrinology practices in China included 273 adults aged ≥18 years with T1D, who were randomly divided in a 2:1 ratio into the unblinded (n = 199) or blinded isCGM group (n = 78). In the blinded group, the clinician used FreeStyle Libre Pro system for monitoring, but self-monitoring was also performed by the patients. RESULTS: Two hundred sixteen (78%) participants completed the study (152 [75%] in the unblinded and 64 [82%] in the blinded group). At 12 weeks, a significant increase in TIR (3.9-10.0 mmol/L) was only observed in the unblinded group, along with a significant decrease in hyperglycemia (>13.9 mmol/L), hypoglycemia (<3.0 mmol/L), glycemic variability. Further, the mean HbA1c reduction from baseline to 12 weeks was 0.5% in the unblinded isCGM group and 0.4% in the blinded isCGM group respectively (P < 0.001), but the significance did not remain after adjustment for between-group differences. Finally, 99.5% of the blinded isCGM values and 93.8% the of unblinded isCGM values were obtained at the final visit. CONCLUSIONS: The unblinded isCGM system was associated with benefits for glucose management, but nearly 100% of the attempted profiles were obtained successfully with the blinded isCGM system. Thus, combining real-time and retrospective data with isCGM might be the most impactful way to utilize flash glycemic monitoring devices. Frontiers Media S.A. 2023-02-22 /pmc/articles/PMC9992877/ /pubmed/36909344 http://dx.doi.org/10.3389/fendo.2023.1110845 Text en Copyright © 2023 Guo, Li, Zhang, Xiao, Kuang, Yang, Jia and Zhang https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Endocrinology Guo, Lixin Li, Yuxiu Zhang, Mei Xiao, Xinhua Kuang, Hongyu Yang, Tao Jia, Xiaofan Zhang, Xianbo Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title | Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title_full | Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title_fullStr | Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title_full_unstemmed | Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title_short | Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
title_sort | efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes |
topic | Endocrinology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9992877/ https://www.ncbi.nlm.nih.gov/pubmed/36909344 http://dx.doi.org/10.3389/fendo.2023.1110845 |
work_keys_str_mv | AT guolixin efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT liyuxiu efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT zhangmei efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT xiaoxinhua efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT kuanghongyu efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT yangtao efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT jiaxiaofan efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes AT zhangxianbo efficacyofunblindedandblindedintermittentlyscannedcontinuousglucosemonitoringforglycemiccontrolinadultswithtype1diabetes |