Cargando…
Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study
BACKGROUND: The GAITRite® system is one of the gold standards for gait electronic analysis, especially for older adults. Previous GAITRite® systems were composed of an electronic roll-up walkway. Recently, a new GAITRite® electronic walkway, named CIRFACE, was commercialized. It is composed of a cha...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9993600/ https://www.ncbi.nlm.nih.gov/pubmed/36882705 http://dx.doi.org/10.1186/s12877-023-03811-7 |
_version_ | 1784902546248171520 |
---|---|
author | Sacco, Guillaume Ben-Sadoun, Grégory Gautier, Jennifer Simon, Romain Goupil, Maude Laureau, Pauline Terrien, Jade Annweiler, Cédric |
author_facet | Sacco, Guillaume Ben-Sadoun, Grégory Gautier, Jennifer Simon, Romain Goupil, Maude Laureau, Pauline Terrien, Jade Annweiler, Cédric |
author_sort | Sacco, Guillaume |
collection | PubMed |
description | BACKGROUND: The GAITRite® system is one of the gold standards for gait electronic analysis, especially for older adults. Previous GAITRite® systems were composed of an electronic roll-up walkway. Recently, a new GAITRite® electronic walkway, named CIRFACE, was commercialized. It is composed of a changeable association of stiff plates, unlike previous models. Are the gait parameters measured similar between these two walkways among older adults and according to the cognitive status, the history of falls, and the use of walking aids? METHODS: In this retrospective observational study, 95 older ambulatory participants (mean, 82.6 ± 5.8 years) were included. Ten spatio-temporal gait parameters were measured simultaneously with the two GAITRite® systems in older adults while walking at comfortable self-selected pace. The GAITRite® Platinum Plus Classic (26’) was superimposed on the GAITRite® CIRFACE (VI). Comparisons between the parameters of the two walkways were performed using Bravais-Pearson correlation, between-method differences (corresponding to bias), percentage errors and Intraclass Correlation Coefficients (ICC(2,1)). Subgroup analyses were performed according to the cognitive status, the history of falls in the last 12 months and the use of walking aids. RESULTS: The whole walk parameters recorded by the two walkways were extremely correlated with a Bravais-Pearson correlation coefficient ranging from 0.968 to 0.999, P < .001, indicating a very high correlation. According to the ICC(2,1) calculated for absolute agreement, all gait parameters had excellent reliability (ranging from 0.938 to 0.999). Mean bias for 9 parameters out of 10 were ranged from − 0.27 to 0.54, with clinically acceptable percentage errors (1.2–10.1%). Step length showed a substantially higher bias (1.4 ± 1.2 cm), nevertheless the percentage errors remained clinically acceptable (5%). CONCLUSION: When walking at comfortable self-selected pace, the standard spatio-temporal walk parameters provided by both the GAITRite® PPC and the GAITRite® CIRFACE seem similar and very highly correlated in older adults with various cognitive or motor status. The data of studies using these systems can be compared and mixed with a very low risk of bias in a meta-analytic process. Also, the geriatric care units can choose the most ergonomic system according to their infrastructure without affecting their gait data. TRIAL REGISTRATION: NCT04557592 (21/09/2020). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12877-023-03811-7. |
format | Online Article Text |
id | pubmed-9993600 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99936002023-03-09 Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study Sacco, Guillaume Ben-Sadoun, Grégory Gautier, Jennifer Simon, Romain Goupil, Maude Laureau, Pauline Terrien, Jade Annweiler, Cédric BMC Geriatr Research BACKGROUND: The GAITRite® system is one of the gold standards for gait electronic analysis, especially for older adults. Previous GAITRite® systems were composed of an electronic roll-up walkway. Recently, a new GAITRite® electronic walkway, named CIRFACE, was commercialized. It is composed of a changeable association of stiff plates, unlike previous models. Are the gait parameters measured similar between these two walkways among older adults and according to the cognitive status, the history of falls, and the use of walking aids? METHODS: In this retrospective observational study, 95 older ambulatory participants (mean, 82.6 ± 5.8 years) were included. Ten spatio-temporal gait parameters were measured simultaneously with the two GAITRite® systems in older adults while walking at comfortable self-selected pace. The GAITRite® Platinum Plus Classic (26’) was superimposed on the GAITRite® CIRFACE (VI). Comparisons between the parameters of the two walkways were performed using Bravais-Pearson correlation, between-method differences (corresponding to bias), percentage errors and Intraclass Correlation Coefficients (ICC(2,1)). Subgroup analyses were performed according to the cognitive status, the history of falls in the last 12 months and the use of walking aids. RESULTS: The whole walk parameters recorded by the two walkways were extremely correlated with a Bravais-Pearson correlation coefficient ranging from 0.968 to 0.999, P < .001, indicating a very high correlation. According to the ICC(2,1) calculated for absolute agreement, all gait parameters had excellent reliability (ranging from 0.938 to 0.999). Mean bias for 9 parameters out of 10 were ranged from − 0.27 to 0.54, with clinically acceptable percentage errors (1.2–10.1%). Step length showed a substantially higher bias (1.4 ± 1.2 cm), nevertheless the percentage errors remained clinically acceptable (5%). CONCLUSION: When walking at comfortable self-selected pace, the standard spatio-temporal walk parameters provided by both the GAITRite® PPC and the GAITRite® CIRFACE seem similar and very highly correlated in older adults with various cognitive or motor status. The data of studies using these systems can be compared and mixed with a very low risk of bias in a meta-analytic process. Also, the geriatric care units can choose the most ergonomic system according to their infrastructure without affecting their gait data. TRIAL REGISTRATION: NCT04557592 (21/09/2020). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12877-023-03811-7. BioMed Central 2023-03-07 /pmc/articles/PMC9993600/ /pubmed/36882705 http://dx.doi.org/10.1186/s12877-023-03811-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Sacco, Guillaume Ben-Sadoun, Grégory Gautier, Jennifer Simon, Romain Goupil, Maude Laureau, Pauline Terrien, Jade Annweiler, Cédric Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title | Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title_full | Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title_fullStr | Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title_full_unstemmed | Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title_short | Comparison of spatio-temporal gait parameters between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults: a retrospective observational study |
title_sort | comparison of spatio-temporal gait parameters between the gaitrite® platinum plus classic and the gaitrite® cirface among older adults: a retrospective observational study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9993600/ https://www.ncbi.nlm.nih.gov/pubmed/36882705 http://dx.doi.org/10.1186/s12877-023-03811-7 |
work_keys_str_mv | AT saccoguillaume comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT bensadoungregory comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT gautierjennifer comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT simonromain comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT goupilmaude comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT laureaupauline comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT terrienjade comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy AT annweilercedric comparisonofspatiotemporalgaitparametersbetweenthegaitriteplatinumplusclassicandthegaitritecirfaceamongolderadultsaretrospectiveobservationalstudy |