Point of Care Ultrasound Diagnosis of Pseudoaneurysm of an Upper Extremity Arteriovenous Dialysis Graft
We describe the rapid diagnosis with point of care ultrasound (POCUS) of two acute pseudoaneurysms of a bovine arteriovenous dialysis graft with superimposed cellulitis in a 44-year old male patient who presented with pain over his upper arm graft site. POCUS evaluation decreased the time to diagnos...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994290/ https://www.ncbi.nlm.nih.gov/pubmed/36896115 http://dx.doi.org/10.24908/pocus.v7iKidney.15021 |
Sumario: | We describe the rapid diagnosis with point of care ultrasound (POCUS) of two acute pseudoaneurysms of a bovine arteriovenous dialysis graft with superimposed cellulitis in a 44-year old male patient who presented with pain over his upper arm graft site. POCUS evaluation decreased the time to diagnosis and vascular surgery consultation. |
---|