Cargando…
‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report
BACKGROUND: Different procedural strategies have been published targeting to facilitate transcatheter left atrial appendage closure (LAAc). We demonstrate feasibility of a procedural set-up allowing single-operator LAAc in a selected patient. CASE SUMMARY: A 87-year-old male with persistent Afib (CH...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994584/ https://www.ncbi.nlm.nih.gov/pubmed/36909837 http://dx.doi.org/10.1093/ehjcr/ytad078 |
_version_ | 1784902647018422272 |
---|---|
author | Hammerstingl, Christoph Yahya, Mohammed Ali Völz, Alexander |
author_facet | Hammerstingl, Christoph Yahya, Mohammed Ali Völz, Alexander |
author_sort | Hammerstingl, Christoph |
collection | PubMed |
description | BACKGROUND: Different procedural strategies have been published targeting to facilitate transcatheter left atrial appendage closure (LAAc). We demonstrate feasibility of a procedural set-up allowing single-operator LAAc in a selected patient. CASE SUMMARY: A 87-year-old male with persistent Afib (CHA(2)DS(2)VASc, five; HASBLED, three) was referred to our hospital for LAAc. Pre-procedural planning and device sizing with three-dimensional transesophageal echocardiography (3DTEE) confirmed a non-complex anatomy of the essential anatomical structures predicting suitability for LAAc. Therefore, the procedure was performed with a simplified single-operator interventional approach. Intraprocedural TEE guidance, device preparation, and LAAc were accomplished by the interventionalist himself. For procedural guidance, the TEE probe was arranged and handled in a technique comparable to the use of intracardiac echocardiography (ICE). Procedure time (skin-to-skin) was 21 min, left atrial access time 9 min, and fluoroscopy time was 4:28 min without the use of contrast dye. The patient was discharged the following day in good medical conditions. DISCUSSION: To the best of our knowledge, this is the first report on successful single-operator LAAc in a selected patient. The intervention, pre-procedural screening, and intraprocedural 3D TEE were performed by one single experienced interventionalist. This simplified technique is based on a standardized pre-procedural imaging-protocol with 3D echocardiography. According to our experience, this streamlined approach is a valuable option in non-complex LAAc cases. In the growing field of structural cardiac interventions, this approach might be an interesting option for centres with limited personal and technical resources. |
format | Online Article Text |
id | pubmed-9994584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-99945842023-03-09 ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report Hammerstingl, Christoph Yahya, Mohammed Ali Völz, Alexander Eur Heart J Case Rep Case Report BACKGROUND: Different procedural strategies have been published targeting to facilitate transcatheter left atrial appendage closure (LAAc). We demonstrate feasibility of a procedural set-up allowing single-operator LAAc in a selected patient. CASE SUMMARY: A 87-year-old male with persistent Afib (CHA(2)DS(2)VASc, five; HASBLED, three) was referred to our hospital for LAAc. Pre-procedural planning and device sizing with three-dimensional transesophageal echocardiography (3DTEE) confirmed a non-complex anatomy of the essential anatomical structures predicting suitability for LAAc. Therefore, the procedure was performed with a simplified single-operator interventional approach. Intraprocedural TEE guidance, device preparation, and LAAc were accomplished by the interventionalist himself. For procedural guidance, the TEE probe was arranged and handled in a technique comparable to the use of intracardiac echocardiography (ICE). Procedure time (skin-to-skin) was 21 min, left atrial access time 9 min, and fluoroscopy time was 4:28 min without the use of contrast dye. The patient was discharged the following day in good medical conditions. DISCUSSION: To the best of our knowledge, this is the first report on successful single-operator LAAc in a selected patient. The intervention, pre-procedural screening, and intraprocedural 3D TEE were performed by one single experienced interventionalist. This simplified technique is based on a standardized pre-procedural imaging-protocol with 3D echocardiography. According to our experience, this streamlined approach is a valuable option in non-complex LAAc cases. In the growing field of structural cardiac interventions, this approach might be an interesting option for centres with limited personal and technical resources. Oxford University Press 2023-02-13 /pmc/articles/PMC9994584/ /pubmed/36909837 http://dx.doi.org/10.1093/ehjcr/ytad078 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Hammerstingl, Christoph Yahya, Mohammed Ali Völz, Alexander ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title | ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title_full | ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title_fullStr | ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title_full_unstemmed | ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title_short | ‘Just the two of us’: single-operator interventional left atrial appendage closure—a case report |
title_sort | ‘just the two of us’: single-operator interventional left atrial appendage closure—a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994584/ https://www.ncbi.nlm.nih.gov/pubmed/36909837 http://dx.doi.org/10.1093/ehjcr/ytad078 |
work_keys_str_mv | AT hammerstinglchristoph justthetwoofussingleoperatorinterventionalleftatrialappendageclosureacasereport AT yahyamohammedali justthetwoofussingleoperatorinterventionalleftatrialappendageclosureacasereport AT volzalexander justthetwoofussingleoperatorinterventionalleftatrialappendageclosureacasereport |