Cargando…

Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method

BACKGROUND: The placement of zygomatic implants is an alternative used for rehabilitation of edentulous patients with atrophic maxilla. However, the complexity of the various techniques suggested in the literature requires high skill from surgeons. Aim: The objective of this research was to compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Costa, Elton-Facco-Alves, Penteado, Marcela-Moreira, Maior, Bruno-Sotto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994652/
https://www.ncbi.nlm.nih.gov/pubmed/36911157
http://dx.doi.org/10.4317/jced.59885
_version_ 1784902658775056384
author Costa, Elton-Facco-Alves
Penteado, Marcela-Moreira
Maior, Bruno-Sotto
author_facet Costa, Elton-Facco-Alves
Penteado, Marcela-Moreira
Maior, Bruno-Sotto
author_sort Costa, Elton-Facco-Alves
collection PubMed
description BACKGROUND: The placement of zygomatic implants is an alternative used for rehabilitation of edentulous patients with atrophic maxilla. However, the complexity of the various techniques suggested in the literature requires high skill from surgeons. Aim: The objective of this research was to compare the biomechanical performance of traditional technique of zygomatic implant placement in relation to a new proposal, the Facco technique, through finite element analysis. MATERIAL AND METHODS: A three-dimensional geometric model of the maxilla was input into computer-aided design software (Rhinoceros version 4.0 SR8). STL file of the geometric models of implants and components supplied by the company Implacil De Bortoli was converted to volumetric solids through reverse engineering by RhinoResurf software (Rhinoceros version 4.0 SR8). Three groups were modeled: traditional technique, Facco technique without frictional contact and Facco technique with frictional contact, following the recommended position in each technique for implant placement. All models received a maxillary bar. Groups were exported to the computer-aided engineering software ANYSYS 19.2, in step format. Mechanical static structural analysis was requested with occlusal load of 120N. All elements were considered isotropic, homogeneous, and linearly elastic. Contacts were considered ideal and system fixation was considered at the bone tissue base. RESULTS: There is similarity between the techniques. Microdeformation values capable of generating undesirable bone resorption were not observed in both techniques. Highest values in the posterior region of Facco technique were computed at the angle of part B close to the posterior implant. CONCLUSIONS: Biomechanical behaviors of the two evaluated zygomatic implant techniques are similar. Prosthetic abutment (pilar Z) modifies the distribution of stresses over the zygomatic implant body. Highest stress peak was found in the pilar Z, but it is within acceptable physiological limits. Key words:Atrophic maxilla, zygomatic implants, surgical techniques, pilar Z, dental implants.
format Online
Article
Text
id pubmed-9994652
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-99946522023-03-09 Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method Costa, Elton-Facco-Alves Penteado, Marcela-Moreira Maior, Bruno-Sotto J Clin Exp Dent Research BACKGROUND: The placement of zygomatic implants is an alternative used for rehabilitation of edentulous patients with atrophic maxilla. However, the complexity of the various techniques suggested in the literature requires high skill from surgeons. Aim: The objective of this research was to compare the biomechanical performance of traditional technique of zygomatic implant placement in relation to a new proposal, the Facco technique, through finite element analysis. MATERIAL AND METHODS: A three-dimensional geometric model of the maxilla was input into computer-aided design software (Rhinoceros version 4.0 SR8). STL file of the geometric models of implants and components supplied by the company Implacil De Bortoli was converted to volumetric solids through reverse engineering by RhinoResurf software (Rhinoceros version 4.0 SR8). Three groups were modeled: traditional technique, Facco technique without frictional contact and Facco technique with frictional contact, following the recommended position in each technique for implant placement. All models received a maxillary bar. Groups were exported to the computer-aided engineering software ANYSYS 19.2, in step format. Mechanical static structural analysis was requested with occlusal load of 120N. All elements were considered isotropic, homogeneous, and linearly elastic. Contacts were considered ideal and system fixation was considered at the bone tissue base. RESULTS: There is similarity between the techniques. Microdeformation values capable of generating undesirable bone resorption were not observed in both techniques. Highest values in the posterior region of Facco technique were computed at the angle of part B close to the posterior implant. CONCLUSIONS: Biomechanical behaviors of the two evaluated zygomatic implant techniques are similar. Prosthetic abutment (pilar Z) modifies the distribution of stresses over the zygomatic implant body. Highest stress peak was found in the pilar Z, but it is within acceptable physiological limits. Key words:Atrophic maxilla, zygomatic implants, surgical techniques, pilar Z, dental implants. Medicina Oral S.L. 2023-02-01 /pmc/articles/PMC9994652/ /pubmed/36911157 http://dx.doi.org/10.4317/jced.59885 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Costa, Elton-Facco-Alves
Penteado, Marcela-Moreira
Maior, Bruno-Sotto
Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title_full Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title_fullStr Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title_full_unstemmed Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title_short Comparative analysis of biomechanical response between zygomatic implant and Facco technique through the three-dimensional finite element method
title_sort comparative analysis of biomechanical response between zygomatic implant and facco technique through the three-dimensional finite element method
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994652/
https://www.ncbi.nlm.nih.gov/pubmed/36911157
http://dx.doi.org/10.4317/jced.59885
work_keys_str_mv AT costaeltonfaccoalves comparativeanalysisofbiomechanicalresponsebetweenzygomaticimplantandfaccotechniquethroughthethreedimensionalfiniteelementmethod
AT penteadomarcelamoreira comparativeanalysisofbiomechanicalresponsebetweenzygomaticimplantandfaccotechniquethroughthethreedimensionalfiniteelementmethod
AT maiorbrunosotto comparativeanalysisofbiomechanicalresponsebetweenzygomaticimplantandfaccotechniquethroughthethreedimensionalfiniteelementmethod