Cargando…

Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA

Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage t...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramezanifar, Ehsan, Gholamizadeh, Kamran, Mohammadfam, Iraj, Mirzaei Aliabadi, Mostafa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994695/
https://www.ncbi.nlm.nih.gov/pubmed/36888639
http://dx.doi.org/10.1371/journal.pone.0282657
_version_ 1784902669984333824
author Ramezanifar, Ehsan
Gholamizadeh, Kamran
Mohammadfam, Iraj
Mirzaei Aliabadi, Mostafa
author_facet Ramezanifar, Ehsan
Gholamizadeh, Kamran
Mohammadfam, Iraj
Mirzaei Aliabadi, Mostafa
author_sort Ramezanifar, Ehsan
collection PubMed
description Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage tank fire. In the quantitative FTA of a system, sufficient data are only sometimes available to calculate the failure probability of the system appertains to study. Thus, the obtained result of the SPA added new value to the Basic Events (BEs) and estimated top event. To illustrate the applicability of the proposed approach, a fault tree of the methanol storage tank fire is performed and analyzed BEs. According to the obtained results, the fire accident was computed by 48 BEs, and the occurrence probability value of the top event was estimated 2.58E-1/year. In addition, the most crucial paths that led to the fire accident are listed in this study. The proposed approach established in the present study can assist decision-makers in determining where to take preventative or appropriate action on the storage tank system. Moreover, it can be adjusted for various systems with limited manipulation.
format Online
Article
Text
id pubmed-9994695
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-99946952023-03-09 Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA Ramezanifar, Ehsan Gholamizadeh, Kamran Mohammadfam, Iraj Mirzaei Aliabadi, Mostafa PLoS One Research Article Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage tank fire. In the quantitative FTA of a system, sufficient data are only sometimes available to calculate the failure probability of the system appertains to study. Thus, the obtained result of the SPA added new value to the Basic Events (BEs) and estimated top event. To illustrate the applicability of the proposed approach, a fault tree of the methanol storage tank fire is performed and analyzed BEs. According to the obtained results, the fire accident was computed by 48 BEs, and the occurrence probability value of the top event was estimated 2.58E-1/year. In addition, the most crucial paths that led to the fire accident are listed in this study. The proposed approach established in the present study can assist decision-makers in determining where to take preventative or appropriate action on the storage tank system. Moreover, it can be adjusted for various systems with limited manipulation. Public Library of Science 2023-03-08 /pmc/articles/PMC9994695/ /pubmed/36888639 http://dx.doi.org/10.1371/journal.pone.0282657 Text en © 2023 Ramezanifar et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ramezanifar, Ehsan
Gholamizadeh, Kamran
Mohammadfam, Iraj
Mirzaei Aliabadi, Mostafa
Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title_full Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title_fullStr Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title_full_unstemmed Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title_short Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
title_sort risk assessment of methanol storage tank fire accident using hybrid fta-spa
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994695/
https://www.ncbi.nlm.nih.gov/pubmed/36888639
http://dx.doi.org/10.1371/journal.pone.0282657
work_keys_str_mv AT ramezanifarehsan riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa
AT gholamizadehkamran riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa
AT mohammadfamiraj riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa
AT mirzaeialiabadimostafa riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa