Cargando…
Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA
Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994695/ https://www.ncbi.nlm.nih.gov/pubmed/36888639 http://dx.doi.org/10.1371/journal.pone.0282657 |
_version_ | 1784902669984333824 |
---|---|
author | Ramezanifar, Ehsan Gholamizadeh, Kamran Mohammadfam, Iraj Mirzaei Aliabadi, Mostafa |
author_facet | Ramezanifar, Ehsan Gholamizadeh, Kamran Mohammadfam, Iraj Mirzaei Aliabadi, Mostafa |
author_sort | Ramezanifar, Ehsan |
collection | PubMed |
description | Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage tank fire. In the quantitative FTA of a system, sufficient data are only sometimes available to calculate the failure probability of the system appertains to study. Thus, the obtained result of the SPA added new value to the Basic Events (BEs) and estimated top event. To illustrate the applicability of the proposed approach, a fault tree of the methanol storage tank fire is performed and analyzed BEs. According to the obtained results, the fire accident was computed by 48 BEs, and the occurrence probability value of the top event was estimated 2.58E-1/year. In addition, the most crucial paths that led to the fire accident are listed in this study. The proposed approach established in the present study can assist decision-makers in determining where to take preventative or appropriate action on the storage tank system. Moreover, it can be adjusted for various systems with limited manipulation. |
format | Online Article Text |
id | pubmed-9994695 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-99946952023-03-09 Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA Ramezanifar, Ehsan Gholamizadeh, Kamran Mohammadfam, Iraj Mirzaei Aliabadi, Mostafa PLoS One Research Article Fire accidents in storage tanks are of great importance due to the difficulty in extinguishing and ease of spread to nearby products. This study aimed to introduce a framework based on FTA-based Set Pair Analysis (SPA) established via experts’ elicitation to identify and assess the risk of storage tank fire. In the quantitative FTA of a system, sufficient data are only sometimes available to calculate the failure probability of the system appertains to study. Thus, the obtained result of the SPA added new value to the Basic Events (BEs) and estimated top event. To illustrate the applicability of the proposed approach, a fault tree of the methanol storage tank fire is performed and analyzed BEs. According to the obtained results, the fire accident was computed by 48 BEs, and the occurrence probability value of the top event was estimated 2.58E-1/year. In addition, the most crucial paths that led to the fire accident are listed in this study. The proposed approach established in the present study can assist decision-makers in determining where to take preventative or appropriate action on the storage tank system. Moreover, it can be adjusted for various systems with limited manipulation. Public Library of Science 2023-03-08 /pmc/articles/PMC9994695/ /pubmed/36888639 http://dx.doi.org/10.1371/journal.pone.0282657 Text en © 2023 Ramezanifar et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ramezanifar, Ehsan Gholamizadeh, Kamran Mohammadfam, Iraj Mirzaei Aliabadi, Mostafa Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title | Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title_full | Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title_fullStr | Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title_full_unstemmed | Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title_short | Risk assessment of methanol storage tank fire accident using hybrid FTA-SPA |
title_sort | risk assessment of methanol storage tank fire accident using hybrid fta-spa |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9994695/ https://www.ncbi.nlm.nih.gov/pubmed/36888639 http://dx.doi.org/10.1371/journal.pone.0282657 |
work_keys_str_mv | AT ramezanifarehsan riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa AT gholamizadehkamran riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa AT mohammadfamiraj riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa AT mirzaeialiabadimostafa riskassessmentofmethanolstoragetankfireaccidentusinghybridftaspa |