Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion

The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-...

Descripción completa

Detalles Bibliográficos
Autores principales: ARAI, Sho, FUJII, Takashi, TERANISHI, Kohsuke, NONAKA, Senshu, KITAMURA, Takayuki, MITOME-MISHIMA, Yumiko, KONDO, Akihide, OISHI, Hidenori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995145/
https://www.ncbi.nlm.nih.gov/pubmed/36543205
http://dx.doi.org/10.2176/jns-nmc.2022-0217
_version_ 1784902762111172608
author ARAI, Sho
FUJII, Takashi
TERANISHI, Kohsuke
NONAKA, Senshu
KITAMURA, Takayuki
MITOME-MISHIMA, Yumiko
KONDO, Akihide
OISHI, Hidenori
author_facet ARAI, Sho
FUJII, Takashi
TERANISHI, Kohsuke
NONAKA, Senshu
KITAMURA, Takayuki
MITOME-MISHIMA, Yumiko
KONDO, Akihide
OISHI, Hidenori
author_sort ARAI, Sho
collection PubMed
description The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-center, retrospective investigation of the safety and efficacy of the Pipeline Flex device to treat these aneurysms. Of the patients who underwent Pipeline implantation for small- and medium-sized ICA aneurysms (≤12 mm) at our hospital between July 2013 and October 2021, 102 patients with 104 aneurysms were included in this study. The mean age of the patients was 57.7 ± 12.1 years, and 94 (90.4%) were female. The mean aneurysmal dome diameter was 9.2 ± 2.3 mm, the mean neck diameter was 5.3 ± 1.6 mm, and the mean dome-to-neck ratio was 1.8 ± 0.5. Twenty-five patients (24.0%) had incorporated vessels from the aneurysm. Complete occlusion of the aneurysms was obtained in 96 patients (92.3%). There were no cases of parent artery stenosis or major stroke after the procedure. Absence of incorporated vessel from the aneurysm dome and adjunctive coil embolization are statistically significant factors indicating complete occlusion in multivariate analysis. The time to complete occlusion was determined earlier with the use of the Pipeline Shield (p = 0.0386) and with adjunctive coils (p = 0.0025). We showed that Pipeline implantation for small- and medium-sized aneurysms was safe and highly effective.
format Online
Article
Text
id pubmed-9995145
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-99951452023-03-09 Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion ARAI, Sho FUJII, Takashi TERANISHI, Kohsuke NONAKA, Senshu KITAMURA, Takayuki MITOME-MISHIMA, Yumiko KONDO, Akihide OISHI, Hidenori Neurol Med Chir (Tokyo) Original Article The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-center, retrospective investigation of the safety and efficacy of the Pipeline Flex device to treat these aneurysms. Of the patients who underwent Pipeline implantation for small- and medium-sized ICA aneurysms (≤12 mm) at our hospital between July 2013 and October 2021, 102 patients with 104 aneurysms were included in this study. The mean age of the patients was 57.7 ± 12.1 years, and 94 (90.4%) were female. The mean aneurysmal dome diameter was 9.2 ± 2.3 mm, the mean neck diameter was 5.3 ± 1.6 mm, and the mean dome-to-neck ratio was 1.8 ± 0.5. Twenty-five patients (24.0%) had incorporated vessels from the aneurysm. Complete occlusion of the aneurysms was obtained in 96 patients (92.3%). There were no cases of parent artery stenosis or major stroke after the procedure. Absence of incorporated vessel from the aneurysm dome and adjunctive coil embolization are statistically significant factors indicating complete occlusion in multivariate analysis. The time to complete occlusion was determined earlier with the use of the Pipeline Shield (p = 0.0386) and with adjunctive coils (p = 0.0025). We showed that Pipeline implantation for small- and medium-sized aneurysms was safe and highly effective. The Japan Neurosurgical Society 2022-12-20 /pmc/articles/PMC9995145/ /pubmed/36543205 http://dx.doi.org/10.2176/jns-nmc.2022-0217 Text en © 2023 The Japan Neurosurgical Society https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License.
spellingShingle Original Article
ARAI, Sho
FUJII, Takashi
TERANISHI, Kohsuke
NONAKA, Senshu
KITAMURA, Takayuki
MITOME-MISHIMA, Yumiko
KONDO, Akihide
OISHI, Hidenori
Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title_full Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title_fullStr Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title_full_unstemmed Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title_short Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion
title_sort pipeline flex with shield technology placement for small- and medium-sized aneurysms achieves early complete occlusion
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995145/
https://www.ncbi.nlm.nih.gov/pubmed/36543205
http://dx.doi.org/10.2176/jns-nmc.2022-0217
work_keys_str_mv AT araisho pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT fujiitakashi pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT teranishikohsuke pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT nonakasenshu pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT kitamuratakayuki pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT mitomemishimayumiko pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT kondoakihide pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion
AT oishihidenori pipelineflexwithshieldtechnologyplacementforsmallandmediumsizedaneurysmsachievesearlycompleteocclusion