Cargando…
The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault
PURPOSE: This study aimed to describe the effectiveness and stability of implantable collamer lens (ICL) rotation in reducing high postoperative vault. SETTING: This study was conducted in the Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. DESIGN: This is a retrospective...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995363/ https://www.ncbi.nlm.nih.gov/pubmed/36910497 http://dx.doi.org/10.3389/fmed.2023.1104047 |
_version_ | 1784902806538289152 |
---|---|
author | Jiang, Yang Luo, Yan Li, Ying Lu, Thomas |
author_facet | Jiang, Yang Luo, Yan Li, Ying Lu, Thomas |
author_sort | Jiang, Yang |
collection | PubMed |
description | PURPOSE: This study aimed to describe the effectiveness and stability of implantable collamer lens (ICL) rotation in reducing high postoperative vault. SETTING: This study was conducted in the Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. DESIGN: This is a retrospective case series. METHODS: Twenty-two eyes from 22 patients who had ICL (V4c EVO) implantation with high postoperative vault (>=750 μm) were recruited for our study. All the lenses were rotated from a horizontal to an oblique position. The vault, SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° were measured pre-rotation, 1-week post-rotation, and in the at-least 1-year-follow-up. RESULTS: Twenty female patients and two male patients were recruited, with a mean age of 28.68 ± 6.08 years. The mean vault had declined significantly from 951.81 ± 154.26 μm pre-rotation to 772.27 ± 119.40 μm 1 week post-rotation (p < 0.001). The SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° pre-rotation and 1-week post-rotation were 30.40 ± 7.91° and 45.14 ± 6.75°, 32.37 ± 7.48° and 46.23 ± 6.39°, 303.27 ± 87.99 and 522.45 ± 122.16 μm, 323.81 ± 89.15 and 536.13 ± 121.66 μm, 387.95 ± 99.43 and 630.81 ± 133.59 μm, 435.68 ± 106.72 and 643.36 ± 132.82 μm, 0.109 ± 0.034 and 0.202 ± 0.053 mm(2), 0.123 ± 0.034 and 0.212 ± 0.051 mm(2), 0.194 ± 0.056 and 0.345 ± 0.083 mm(2), and 0.216 ± 0.055 and 0.358 ± 0.079 mm(2) (all p < 0.001). The mean vault value had changed from 747.50 ± 116.07 μm 1-week post-rotation to 586.87 ± 132.65 μm in the 1-year follow-up. However, the SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° had remained stable (p > 0.05). CONCLUSION: Non-toric ICL rotation is a novel and effective technique in the treatment of high postoperative vault. Our results are more robust given the extended period of follow-up. |
format | Online Article Text |
id | pubmed-9995363 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99953632023-03-10 The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault Jiang, Yang Luo, Yan Li, Ying Lu, Thomas Front Med (Lausanne) Medicine PURPOSE: This study aimed to describe the effectiveness and stability of implantable collamer lens (ICL) rotation in reducing high postoperative vault. SETTING: This study was conducted in the Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. DESIGN: This is a retrospective case series. METHODS: Twenty-two eyes from 22 patients who had ICL (V4c EVO) implantation with high postoperative vault (>=750 μm) were recruited for our study. All the lenses were rotated from a horizontal to an oblique position. The vault, SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° were measured pre-rotation, 1-week post-rotation, and in the at-least 1-year-follow-up. RESULTS: Twenty female patients and two male patients were recruited, with a mean age of 28.68 ± 6.08 years. The mean vault had declined significantly from 951.81 ± 154.26 μm pre-rotation to 772.27 ± 119.40 μm 1 week post-rotation (p < 0.001). The SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° pre-rotation and 1-week post-rotation were 30.40 ± 7.91° and 45.14 ± 6.75°, 32.37 ± 7.48° and 46.23 ± 6.39°, 303.27 ± 87.99 and 522.45 ± 122.16 μm, 323.81 ± 89.15 and 536.13 ± 121.66 μm, 387.95 ± 99.43 and 630.81 ± 133.59 μm, 435.68 ± 106.72 and 643.36 ± 132.82 μm, 0.109 ± 0.034 and 0.202 ± 0.053 mm(2), 0.123 ± 0.034 and 0.212 ± 0.051 mm(2), 0.194 ± 0.056 and 0.345 ± 0.083 mm(2), and 0.216 ± 0.055 and 0.358 ± 0.079 mm(2) (all p < 0.001). The mean vault value had changed from 747.50 ± 116.07 μm 1-week post-rotation to 586.87 ± 132.65 μm in the 1-year follow-up. However, the SSA, AOD500, AOD750, TISA500, and TISA750 at 180° and 0° had remained stable (p > 0.05). CONCLUSION: Non-toric ICL rotation is a novel and effective technique in the treatment of high postoperative vault. Our results are more robust given the extended period of follow-up. Frontiers Media S.A. 2023-02-23 /pmc/articles/PMC9995363/ /pubmed/36910497 http://dx.doi.org/10.3389/fmed.2023.1104047 Text en Copyright © 2023 Jiang, Luo, Li and Lu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Jiang, Yang Luo, Yan Li, Ying Lu, Thomas The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title | The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title_full | The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title_fullStr | The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title_full_unstemmed | The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title_short | The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
title_sort | long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995363/ https://www.ncbi.nlm.nih.gov/pubmed/36910497 http://dx.doi.org/10.3389/fmed.2023.1104047 |
work_keys_str_mv | AT jiangyang thelongtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT luoyan thelongtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT liying thelongtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT luthomas thelongtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT jiangyang longtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT luoyan longtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT liying longtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault AT luthomas longtermobservationoftherotationofimplantablecollamerlensasthemanagementofhighpostoperativevault |