Cargando…
Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony
PURPOSE: To explore the effect of corneal spherical aberration on the visual acuity and visual quality of eyes implanted with the TECNIS Symfony intraocular lens (IOL). METHODS: A total of 43 patients with age-related cataract (60 eyes) undergoing phacoemulsification and TECNIS Symfony IOL implantat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995440/ https://www.ncbi.nlm.nih.gov/pubmed/36910491 http://dx.doi.org/10.3389/fmed.2023.1094966 |
_version_ | 1784902824698576896 |
---|---|
author | Wang, Dandan Liu, Chunlu Guan, Weichen Lu, Ziyi Zhao, Yinying Zhao, Yune |
author_facet | Wang, Dandan Liu, Chunlu Guan, Weichen Lu, Ziyi Zhao, Yinying Zhao, Yune |
author_sort | Wang, Dandan |
collection | PubMed |
description | PURPOSE: To explore the effect of corneal spherical aberration on the visual acuity and visual quality of eyes implanted with the TECNIS Symfony intraocular lens (IOL). METHODS: A total of 43 patients with age-related cataract (60 eyes) undergoing phacoemulsification and TECNIS Symfony IOL implantation were enrolled in this study. The uncorrected distance (UDVA), intermediate (UIVA), near visual acuity (UNVA), corrected distance visual acuity (CDVA), contrast sensitivity, and ocular spherical aberration were recorded 3 months after surgery. Preoperative and postoperative corneal spherical aberration were also measured using the iTrace device. Objective scattering index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) were measured by the Optical Quality Analyzing System. Catquest-9SF questionnaire were applied too. Spearman’s correlation analysis was used to evaluate the relationship between spherical aberration and visual quality parameters. RESULTS: Patients were satisfied with their postoperatively visual quality. And the postoperative logMAR UDVA, UIVA, UNVA, and CDVA was 0.05 ± 0.07, 0.04 ± 0.06, 0.15 ± 0.07, and 0.03 ± 0.05, respectively. The mean preoperative corneal spherical aberration was 0.24 ± 0.10 μm, which is the only factor influencing postoperatively UNVA, and it was negatively correlated with UNVA and glare contrast sensitivity under 18 cpd (cycle/degree, cpd) spatial frequency (r = −0.403, −0.300, −0.360; all P < 0.05). Additionally, the greater the residual spherical aberration of the cornea, the better the near vision after operation. The mean postoperative ocular spherical aberration was −0.03 ± 0.07 μm, it was not correlated with visual acuity, contrast sensitivity, and visual quality (all P > 0.05). CONCLUSION: Preoperative positive spherical aberration can benefit near vision while decrease contrast sensitivities at high spatial frequencies when implanted with the TECNIS Symfony IOL. |
format | Online Article Text |
id | pubmed-9995440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99954402023-03-10 Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony Wang, Dandan Liu, Chunlu Guan, Weichen Lu, Ziyi Zhao, Yinying Zhao, Yune Front Med (Lausanne) Medicine PURPOSE: To explore the effect of corneal spherical aberration on the visual acuity and visual quality of eyes implanted with the TECNIS Symfony intraocular lens (IOL). METHODS: A total of 43 patients with age-related cataract (60 eyes) undergoing phacoemulsification and TECNIS Symfony IOL implantation were enrolled in this study. The uncorrected distance (UDVA), intermediate (UIVA), near visual acuity (UNVA), corrected distance visual acuity (CDVA), contrast sensitivity, and ocular spherical aberration were recorded 3 months after surgery. Preoperative and postoperative corneal spherical aberration were also measured using the iTrace device. Objective scattering index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) were measured by the Optical Quality Analyzing System. Catquest-9SF questionnaire were applied too. Spearman’s correlation analysis was used to evaluate the relationship between spherical aberration and visual quality parameters. RESULTS: Patients were satisfied with their postoperatively visual quality. And the postoperative logMAR UDVA, UIVA, UNVA, and CDVA was 0.05 ± 0.07, 0.04 ± 0.06, 0.15 ± 0.07, and 0.03 ± 0.05, respectively. The mean preoperative corneal spherical aberration was 0.24 ± 0.10 μm, which is the only factor influencing postoperatively UNVA, and it was negatively correlated with UNVA and glare contrast sensitivity under 18 cpd (cycle/degree, cpd) spatial frequency (r = −0.403, −0.300, −0.360; all P < 0.05). Additionally, the greater the residual spherical aberration of the cornea, the better the near vision after operation. The mean postoperative ocular spherical aberration was −0.03 ± 0.07 μm, it was not correlated with visual acuity, contrast sensitivity, and visual quality (all P > 0.05). CONCLUSION: Preoperative positive spherical aberration can benefit near vision while decrease contrast sensitivities at high spatial frequencies when implanted with the TECNIS Symfony IOL. Frontiers Media S.A. 2023-02-23 /pmc/articles/PMC9995440/ /pubmed/36910491 http://dx.doi.org/10.3389/fmed.2023.1094966 Text en Copyright © 2023 Wang, Liu, Guan, Lu, Zhao and Zhao. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Wang, Dandan Liu, Chunlu Guan, Weichen Lu, Ziyi Zhao, Yinying Zhao, Yune Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title | Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title_full | Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title_fullStr | Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title_full_unstemmed | Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title_short | Effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the TECNIS Symfony |
title_sort | effect of larger corneal spherical aberration in improving the near visual acuity of eyes implanted with the tecnis symfony |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995440/ https://www.ncbi.nlm.nih.gov/pubmed/36910491 http://dx.doi.org/10.3389/fmed.2023.1094966 |
work_keys_str_mv | AT wangdandan effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony AT liuchunlu effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony AT guanweichen effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony AT luziyi effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony AT zhaoyinying effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony AT zhaoyune effectoflargercornealsphericalaberrationinimprovingthenearvisualacuityofeyesimplantedwiththetecnissymfony |