Cargando…

Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT

Objective: The instrument THERapy-related InterACTion (THER-I-ACT) was developed to document therapeutic interactions comprehensively in the human therapist–patient setting. Here, we investigate whether the instrument can also reliably be used to characterise therapeutic interactions when a digital...

Descripción completa

Detalles Bibliográficos
Autores principales: Platz, Thomas, Pedersen, Ann Louise, Bobe, Stephanie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995750/
https://www.ncbi.nlm.nih.gov/pubmed/36909363
http://dx.doi.org/10.3389/frobt.2023.1091283
_version_ 1784902887700168704
author Platz, Thomas
Pedersen, Ann Louise
Bobe, Stephanie
author_facet Platz, Thomas
Pedersen, Ann Louise
Bobe, Stephanie
author_sort Platz, Thomas
collection PubMed
description Objective: The instrument THERapy-related InterACTion (THER-I-ACT) was developed to document therapeutic interactions comprehensively in the human therapist–patient setting. Here, we investigate whether the instrument can also reliably be used to characterise therapeutic interactions when a digital system with a humanoid robot as a therapeutic assistant is used. Methods: Participants and therapy: Seventeen stroke survivors receiving arm rehabilitation (i.e., arm basis training (ABT) for moderate-to-severe arm paresis [n = 9] or arm ability training (AAT) for mild arm paresis [n = 8]) using the digital therapy system E-BRAiN over a course of nine sessions. Analysis of the therapeutic interaction: A total of 34 therapy sessions were videotaped. All therapeutic interactions provided by the humanoid robot during the first and the last (9th) session of daily training were documented both in terms of their frequency and time used for that type of interaction using THER-I-ACT. Any additional therapeutic interaction spontaneously given by the supervising staff or a human helper providing physical assistance (ABT only) was also documented. All ratings were performed by two trained independent raters. Statistical analyses: Intraclass correlation coefficients (ICCs) were calculated for the frequency of occurrence and time used for each category of interaction observed. Results: Therapeutic interactions could comprehensively be documented and were observed across the dimensions provision of information, feedback, and bond-related interactions. ICCs for therapeutic interaction category assessments from 34 therapy sessions by two independent raters were high (ICC ≥0.90) for almost all categories of the therapeutic interaction observed, both for the occurrence frequency and time used for categories of therapeutic interactions, and both for the therapeutic interaction performed by the robot and, even though much less frequently observed, additional spontaneous therapeutic interactions by the supervisory staff and a helper being present. The ICC was similarly high for an overall subjective rating of the concentration and engagement of patients (0.87). Conclusion: Therapeutic interactions can comprehensively and reliably be documented by trained raters using the instrument THER-I-ACT not only in the traditional patient–therapist setting, as previously shown, but also in a digital therapy setting with a humanoid robot as the therapeutic agent and for more complex therapeutic settings with more than one therapeutic agent being present.
format Online
Article
Text
id pubmed-9995750
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-99957502023-03-10 Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT Platz, Thomas Pedersen, Ann Louise Bobe, Stephanie Front Robot AI Robotics and AI Objective: The instrument THERapy-related InterACTion (THER-I-ACT) was developed to document therapeutic interactions comprehensively in the human therapist–patient setting. Here, we investigate whether the instrument can also reliably be used to characterise therapeutic interactions when a digital system with a humanoid robot as a therapeutic assistant is used. Methods: Participants and therapy: Seventeen stroke survivors receiving arm rehabilitation (i.e., arm basis training (ABT) for moderate-to-severe arm paresis [n = 9] or arm ability training (AAT) for mild arm paresis [n = 8]) using the digital therapy system E-BRAiN over a course of nine sessions. Analysis of the therapeutic interaction: A total of 34 therapy sessions were videotaped. All therapeutic interactions provided by the humanoid robot during the first and the last (9th) session of daily training were documented both in terms of their frequency and time used for that type of interaction using THER-I-ACT. Any additional therapeutic interaction spontaneously given by the supervising staff or a human helper providing physical assistance (ABT only) was also documented. All ratings were performed by two trained independent raters. Statistical analyses: Intraclass correlation coefficients (ICCs) were calculated for the frequency of occurrence and time used for each category of interaction observed. Results: Therapeutic interactions could comprehensively be documented and were observed across the dimensions provision of information, feedback, and bond-related interactions. ICCs for therapeutic interaction category assessments from 34 therapy sessions by two independent raters were high (ICC ≥0.90) for almost all categories of the therapeutic interaction observed, both for the occurrence frequency and time used for categories of therapeutic interactions, and both for the therapeutic interaction performed by the robot and, even though much less frequently observed, additional spontaneous therapeutic interactions by the supervisory staff and a helper being present. The ICC was similarly high for an overall subjective rating of the concentration and engagement of patients (0.87). Conclusion: Therapeutic interactions can comprehensively and reliably be documented by trained raters using the instrument THER-I-ACT not only in the traditional patient–therapist setting, as previously shown, but also in a digital therapy setting with a humanoid robot as the therapeutic agent and for more complex therapeutic settings with more than one therapeutic agent being present. Frontiers Media S.A. 2023-02-23 /pmc/articles/PMC9995750/ /pubmed/36909363 http://dx.doi.org/10.3389/frobt.2023.1091283 Text en Copyright © 2023 Platz, Pedersen and Bobe. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Robotics and AI
Platz, Thomas
Pedersen, Ann Louise
Bobe, Stephanie
Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title_full Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title_fullStr Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title_full_unstemmed Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title_short Feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument THER-I-ACT
title_sort feasibility, coverage, and inter-rater reliability of the assessment of therapeutic interaction by a humanoid robot providing arm rehabilitation to stroke survivors using the instrument ther-i-act
topic Robotics and AI
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9995750/
https://www.ncbi.nlm.nih.gov/pubmed/36909363
http://dx.doi.org/10.3389/frobt.2023.1091283
work_keys_str_mv AT platzthomas feasibilitycoverageandinterraterreliabilityoftheassessmentoftherapeuticinteractionbyahumanoidrobotprovidingarmrehabilitationtostrokesurvivorsusingtheinstrumenttheriact
AT pedersenannlouise feasibilitycoverageandinterraterreliabilityoftheassessmentoftherapeuticinteractionbyahumanoidrobotprovidingarmrehabilitationtostrokesurvivorsusingtheinstrumenttheriact
AT bobestephanie feasibilitycoverageandinterraterreliabilityoftheassessmentoftherapeuticinteractionbyahumanoidrobotprovidingarmrehabilitationtostrokesurvivorsusingtheinstrumenttheriact