Cargando…

The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke

OBJECTIVE: To investigate the diagnostic value of quantitative parameters of spectral computed tomography (CT) in ischaemic stroke areas. METHODS: The medical records of 57 patients with acute ischaemic stroke (AIS) who underwent plain computed tomography (CT) head scans, CT angiography (CTA), and C...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Jian, Chen, Jinghua, Wang, Ximing, Hao, Ling, Zhang, Jinfeng, Zhang, Xiaohui, Sheng, Zhihong, Liu, Kefu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996291/
https://www.ncbi.nlm.nih.gov/pubmed/36908613
http://dx.doi.org/10.3389/fneur.2023.1056941
_version_ 1784903011376562176
author Huang, Jian
Chen, Jinghua
Wang, Ximing
Hao, Ling
Zhang, Jinfeng
Zhang, Xiaohui
Sheng, Zhihong
Liu, Kefu
author_facet Huang, Jian
Chen, Jinghua
Wang, Ximing
Hao, Ling
Zhang, Jinfeng
Zhang, Xiaohui
Sheng, Zhihong
Liu, Kefu
author_sort Huang, Jian
collection PubMed
description OBJECTIVE: To investigate the diagnostic value of quantitative parameters of spectral computed tomography (CT) in ischaemic stroke areas. METHODS: The medical records of 57 patients with acute ischaemic stroke (AIS) who underwent plain computed tomography (CT) head scans, CT angiography (CTA), and CT perfusion (CTP) were retrospectively reviewed. The ischaemic areas (including the core infarct area and penumbra) and non-ischaemic areas in each patient were quantitatively analyzed using F-STROKE software. Two independent readers measured the corresponding values of the spectroscopic quantitative parameters (effective atomic number [Zeff value], iodine density value, and iodine–no-water value) in the ischaemic area and contralateral normal area alone. The differences in spectroscopic quantitative parameters between the two groups were compared, and their diagnostic efficacy was obtained. RESULTS: The Zeff, iodine–no-water value, and iodine density value of the ischaemic area all showed significant lower than those of non-ischaemic tissue (P < 0.001). For differentiating the ischaemic area from non-ischaemic tissue, the area under the curve (AUC) of the Zeff value reached 0.869 (cut-off value: 7.385; sensitivity: 93.0%; specificity: 70.2%), the AUC of the iodine density value reached 0.932 (cut-off value: 0.235; sensitivity: 91.2%; specificity: 82.5%), and the AUC of the iodine–no-water value reached 0.922 (cut-off value: 0.205; sensitivity: 96.5%; specificity: 78.9%). CONCLUSION: The study showed the spectral CT would be a potential novel rapid method for identifying AIS. The spectral CT quantitative parameters (Zeff, iodine density values, and iodine–no-water values) can effectively differentiate the ischaemic area from non-ischaemic tissue in stroke patients.
format Online
Article
Text
id pubmed-9996291
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-99962912023-03-10 The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke Huang, Jian Chen, Jinghua Wang, Ximing Hao, Ling Zhang, Jinfeng Zhang, Xiaohui Sheng, Zhihong Liu, Kefu Front Neurol Neurology OBJECTIVE: To investigate the diagnostic value of quantitative parameters of spectral computed tomography (CT) in ischaemic stroke areas. METHODS: The medical records of 57 patients with acute ischaemic stroke (AIS) who underwent plain computed tomography (CT) head scans, CT angiography (CTA), and CT perfusion (CTP) were retrospectively reviewed. The ischaemic areas (including the core infarct area and penumbra) and non-ischaemic areas in each patient were quantitatively analyzed using F-STROKE software. Two independent readers measured the corresponding values of the spectroscopic quantitative parameters (effective atomic number [Zeff value], iodine density value, and iodine–no-water value) in the ischaemic area and contralateral normal area alone. The differences in spectroscopic quantitative parameters between the two groups were compared, and their diagnostic efficacy was obtained. RESULTS: The Zeff, iodine–no-water value, and iodine density value of the ischaemic area all showed significant lower than those of non-ischaemic tissue (P < 0.001). For differentiating the ischaemic area from non-ischaemic tissue, the area under the curve (AUC) of the Zeff value reached 0.869 (cut-off value: 7.385; sensitivity: 93.0%; specificity: 70.2%), the AUC of the iodine density value reached 0.932 (cut-off value: 0.235; sensitivity: 91.2%; specificity: 82.5%), and the AUC of the iodine–no-water value reached 0.922 (cut-off value: 0.205; sensitivity: 96.5%; specificity: 78.9%). CONCLUSION: The study showed the spectral CT would be a potential novel rapid method for identifying AIS. The spectral CT quantitative parameters (Zeff, iodine density values, and iodine–no-water values) can effectively differentiate the ischaemic area from non-ischaemic tissue in stroke patients. Frontiers Media S.A. 2023-02-23 /pmc/articles/PMC9996291/ /pubmed/36908613 http://dx.doi.org/10.3389/fneur.2023.1056941 Text en Copyright © 2023 Huang, Chen, Wang, Hao, Zhang, Zhang, Sheng and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Huang, Jian
Chen, Jinghua
Wang, Ximing
Hao, Ling
Zhang, Jinfeng
Zhang, Xiaohui
Sheng, Zhihong
Liu, Kefu
The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title_full The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title_fullStr The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title_full_unstemmed The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title_short The diagnostic value of quantitative parameters on dual-layer detector-based spectral CT in identifying ischaemic stroke
title_sort diagnostic value of quantitative parameters on dual-layer detector-based spectral ct in identifying ischaemic stroke
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996291/
https://www.ncbi.nlm.nih.gov/pubmed/36908613
http://dx.doi.org/10.3389/fneur.2023.1056941
work_keys_str_mv AT huangjian thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT chenjinghua thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT wangximing thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT haoling thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT zhangjinfeng thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT zhangxiaohui thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT shengzhihong thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT liukefu thediagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT huangjian diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT chenjinghua diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT wangximing diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT haoling diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT zhangjinfeng diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT zhangxiaohui diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT shengzhihong diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke
AT liukefu diagnosticvalueofquantitativeparametersonduallayerdetectorbasedspectralctinidentifyingischaemicstroke