Cargando…

PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible

PowerScope 2 is a fixed functional appliance for patients with Class II malocclusion and a retrognathic mandible, that has recently received attention due to its pronounced advantages, for both orthodontists and patients. OBJECTIVE: of study: This study evaluated the action of the PowerScope 2 appli...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Hamdany, Afrah Khazal, Hasan, Lamiaa A., Alrawi, Mohammed Najeeb Abdullah, Alhajar, Emad Hazim Kasim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996435/
https://www.ncbi.nlm.nih.gov/pubmed/36911176
http://dx.doi.org/10.1016/j.jobcr.2023.02.014
_version_ 1784903043470327808
author Al Hamdany, Afrah Khazal
Hasan, Lamiaa A.
Alrawi, Mohammed Najeeb Abdullah
Alhajar, Emad Hazim Kasim
author_facet Al Hamdany, Afrah Khazal
Hasan, Lamiaa A.
Alrawi, Mohammed Najeeb Abdullah
Alhajar, Emad Hazim Kasim
author_sort Al Hamdany, Afrah Khazal
collection PubMed
description PowerScope 2 is a fixed functional appliance for patients with Class II malocclusion and a retrognathic mandible, that has recently received attention due to its pronounced advantages, for both orthodontists and patients. OBJECTIVE: of study: This study evaluated the action of the PowerScope 2 appliance for correcting Class II malocclusion and the stresses and displacement of the mandible during loading using three-dimensional finite element analysis (FEA). The sites of the mandibular skeletal and/or dental corrections were also distinguished. MATERIALS AND METHODS: Using the AutoCAD (2010) Program, a 3D model of the human mandible with teeth was created based on a CT image of a 20-yr-old patient. Orthodontic stainless-steel brackets with Standard Edgewise (0.022 in) slots bonded to five mandibular teeth and inserted into a bounded tube on the first molar were simulated. A rectangular archwire (0.019 × 0.025 in) ligated the brackets. The created models were uploaded to the Autodesk Inventor Professional Computer Program (FE) version (2020). RESULTS: The FEA presented the three-dimensional results qualitatively and quantitatively as von Mises stress and displacement. The colour ruler on the upper left side demonstrates the stress and displacement distribution pattern of the mandible, with the minimum value in blue and the maximum value in red. Mandibular movement was achieved three-dimensionally. There was obvious sagittal forward mandibular movement, and high stress was observed at the chin prominence (the pogonion). In the transverse plane, the mandible was highly bent buccally, especially at the gonial angle and antegonial notch. In the vertical plane, the highest ranges of mandibular movements were seen in the chin, the anterior part of the mandibular body, and the associated dentoalveolar region. CONCLUSIONS: The results of this FEA, PowerScope 2 functional appliance proved to be effective as a Class II malocclusion corrector. Its mode of action on the mandible was achieved in three planes of space, and its orthodontic effects were gained dentally and skeletally. An bbvious sagittal forward mandibular movement was observed, particularly at the chin prominence. Apparent buccal bending, especially at the gonial angle and antegonial notch, was observed. Vertically, the chin and anterior part of the mandible, with the associated dentoalveolar structures, were clearly stressed under the action of this appliance.
format Online
Article
Text
id pubmed-9996435
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99964352023-03-10 PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible Al Hamdany, Afrah Khazal Hasan, Lamiaa A. Alrawi, Mohammed Najeeb Abdullah Alhajar, Emad Hazim Kasim J Oral Biol Craniofac Res Article PowerScope 2 is a fixed functional appliance for patients with Class II malocclusion and a retrognathic mandible, that has recently received attention due to its pronounced advantages, for both orthodontists and patients. OBJECTIVE: of study: This study evaluated the action of the PowerScope 2 appliance for correcting Class II malocclusion and the stresses and displacement of the mandible during loading using three-dimensional finite element analysis (FEA). The sites of the mandibular skeletal and/or dental corrections were also distinguished. MATERIALS AND METHODS: Using the AutoCAD (2010) Program, a 3D model of the human mandible with teeth was created based on a CT image of a 20-yr-old patient. Orthodontic stainless-steel brackets with Standard Edgewise (0.022 in) slots bonded to five mandibular teeth and inserted into a bounded tube on the first molar were simulated. A rectangular archwire (0.019 × 0.025 in) ligated the brackets. The created models were uploaded to the Autodesk Inventor Professional Computer Program (FE) version (2020). RESULTS: The FEA presented the three-dimensional results qualitatively and quantitatively as von Mises stress and displacement. The colour ruler on the upper left side demonstrates the stress and displacement distribution pattern of the mandible, with the minimum value in blue and the maximum value in red. Mandibular movement was achieved three-dimensionally. There was obvious sagittal forward mandibular movement, and high stress was observed at the chin prominence (the pogonion). In the transverse plane, the mandible was highly bent buccally, especially at the gonial angle and antegonial notch. In the vertical plane, the highest ranges of mandibular movements were seen in the chin, the anterior part of the mandibular body, and the associated dentoalveolar region. CONCLUSIONS: The results of this FEA, PowerScope 2 functional appliance proved to be effective as a Class II malocclusion corrector. Its mode of action on the mandible was achieved in three planes of space, and its orthodontic effects were gained dentally and skeletally. An bbvious sagittal forward mandibular movement was observed, particularly at the chin prominence. Apparent buccal bending, especially at the gonial angle and antegonial notch, was observed. Vertically, the chin and anterior part of the mandible, with the associated dentoalveolar structures, were clearly stressed under the action of this appliance. Elsevier 2023 2023-03-01 /pmc/articles/PMC9996435/ /pubmed/36911176 http://dx.doi.org/10.1016/j.jobcr.2023.02.014 Text en © 2023 The Authors. Published by Elsevier B.V. on behalf of Craniofacial Research Foundation. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Al Hamdany, Afrah Khazal
Hasan, Lamiaa A.
Alrawi, Mohammed Najeeb Abdullah
Alhajar, Emad Hazim Kasim
PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title_full PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title_fullStr PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title_full_unstemmed PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title_short PowerScope 2 functional appliance: A 3D finite element simulation of its action on the mandible
title_sort powerscope 2 functional appliance: a 3d finite element simulation of its action on the mandible
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9996435/
https://www.ncbi.nlm.nih.gov/pubmed/36911176
http://dx.doi.org/10.1016/j.jobcr.2023.02.014
work_keys_str_mv AT alhamdanyafrahkhazal powerscope2functionalappliancea3dfiniteelementsimulationofitsactiononthemandible
AT hasanlamiaaa powerscope2functionalappliancea3dfiniteelementsimulationofitsactiononthemandible
AT alrawimohammednajeebabdullah powerscope2functionalappliancea3dfiniteelementsimulationofitsactiononthemandible
AT alhajaremadhazimkasim powerscope2functionalappliancea3dfiniteelementsimulationofitsactiononthemandible