Cargando…

Multiparameters Associated to Successful Weaning from VA ECMO in Adult Patients with Cardiogenic Shock or Cardiac Arrest: Systematic Review and Meta-Analysis

Venoarterial extracorporeal membrane oxygenation (VA ECMO) is a form of temporary mechanical circulatory support and simultaneous extracorporeal gas exchange for acute cardiorespiratory failure, including refractory cardiogenic shock (CS) and cardiac arrest (CA). Few studies have assessed predictors...

Descripción completa

Detalles Bibliográficos
Autores principales: Burgos, Lucrecia María, Seoane, Leonardo, Diez, Mirta, Baro Vila, Rocío Consuelo, Furmento, Juan Francisco, Vrancic, Mariano, Aissaoui, Nadia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997464/
https://www.ncbi.nlm.nih.gov/pubmed/36722581
http://dx.doi.org/10.4103/aca.aca_79_22
Descripción
Sumario:Venoarterial extracorporeal membrane oxygenation (VA ECMO) is a form of temporary mechanical circulatory support and simultaneous extracorporeal gas exchange for acute cardiorespiratory failure, including refractory cardiogenic shock (CS) and cardiac arrest (CA). Few studies have assessed predictors of successful weaning (SW) from VA ECMO. This systematic review and meta-analysis aimed to identify a multiparameter strategy associated with SW from VA ECMO. PubMed and the Cochrane Library and the International Clinical Trials Registry Platform were searched. Studies reporting adult patients with CS or CA treated with VA ECMO published from the year 2000 onwards were included. Primary outcomes were hemodynamic, laboratory, and echocardiography parameters associated with a VA ECMO SW. A total of 11 studies (n=653) were included in this review. Pooled VA ECMO SW was 45% (95%CI: 39–50%, I2 7%) and in-hospital mortality rate was 46.6% (95%CI: 33–60%; I2 36%). In the SW group, pulse pressure [MD 12.7 (95%CI: 7.3–18) I2 = 0%] and mean blood pressure [MD 20.15 (95%CI: 13.8–26.4 I2 = 0) were higher. They also had lower values of creatinine [MD –0.59 (95%CI: –0.9 to –0.2) I2 = 7%], lactate [MD –3.1 (95%CI: –5.4 to –0.7) I2 = 89%], and creatine kinase [–2779.5 (95%CI: –5387 to –171) I2 = 38%]. And higher left and right ventricular ejection fraction, MD 17.9% (95%CI: –0.2–36.2) I2 = 91%, and MD 15.9% (95%CI 11.9–20) I2 = 0%, respectively. Different hemodynamic, laboratory, and echocardiographic parameters were associated with successful device removal. This systematic review demonstrated the relationship of multiparametric assessment on VA ECMO SW.