Cargando…

A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy

This paper aims to provide guidance and a framework for commissioning tests and tolerances for the ExacTrac Dynamic image-guided and surface-guided radiotherapy (SGRT) system. ExacTrac Dynamic includes a stereoscopic X-ray system, a structured light projector, stereoscopic cameras, thermal camera fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Perrett, Ben, Ukath, Jaysree, Horgan, Emma, Noble, Chris, Ramachandran, Prabhakar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997535/
https://www.ncbi.nlm.nih.gov/pubmed/36908493
http://dx.doi.org/10.4103/jmp.jmp_67_22
_version_ 1784903273965158400
author Perrett, Ben
Ukath, Jaysree
Horgan, Emma
Noble, Chris
Ramachandran, Prabhakar
author_facet Perrett, Ben
Ukath, Jaysree
Horgan, Emma
Noble, Chris
Ramachandran, Prabhakar
author_sort Perrett, Ben
collection PubMed
description This paper aims to provide guidance and a framework for commissioning tests and tolerances for the ExacTrac Dynamic image-guided and surface-guided radiotherapy (SGRT) system. ExacTrac Dynamic includes a stereoscopic X-ray system, a structured light projector, stereoscopic cameras, thermal camera for SGRT, and has the capability to track breath holds and internal markers. The system provides fast and accurate image guidance and intrafraction guidance for stereotactic radiosurgery and stereotactic ablative radiotherapy. ExacTrac Dynamic was commissioned on a recently installed Elekta Versa HD. Commissioning tests are described including safety, isocenter calibration, dosimetry, image quality, data transfer, SGRT stability, SGRT localization, gating, fusion, implanted markers, breath hold, and end-to-end testing. Custom phantom designs have been implemented for assessment of the deep inspiration breath-hold workflow, the implanted markers workflow, and for gating tests where remote-controlled movement of a phantom is required. Commissioning tests were all found to be in tolerance, with maximum translational and rotational deviations in SGRT of 0.3 mm and 0.4°, respectively, and X-ray image fusion reproducibility standard deviation of 0.08 mm. Tolerances were based on published documents and upon the performance characteristics of the system as specified by the vendor. The unique configuration of ExacTrac Dynamic requires the end user to design commissioning tests that validate the system for use in the clinical implementation adopted in the department. As there are multiple customizable workflows available, tests should be designed around these workflows, and can be ongoing as workflows are progressively introduced into departmental procedures.
format Online
Article
Text
id pubmed-9997535
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-99975352023-03-10 A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy Perrett, Ben Ukath, Jaysree Horgan, Emma Noble, Chris Ramachandran, Prabhakar J Med Phys Technical Note This paper aims to provide guidance and a framework for commissioning tests and tolerances for the ExacTrac Dynamic image-guided and surface-guided radiotherapy (SGRT) system. ExacTrac Dynamic includes a stereoscopic X-ray system, a structured light projector, stereoscopic cameras, thermal camera for SGRT, and has the capability to track breath holds and internal markers. The system provides fast and accurate image guidance and intrafraction guidance for stereotactic radiosurgery and stereotactic ablative radiotherapy. ExacTrac Dynamic was commissioned on a recently installed Elekta Versa HD. Commissioning tests are described including safety, isocenter calibration, dosimetry, image quality, data transfer, SGRT stability, SGRT localization, gating, fusion, implanted markers, breath hold, and end-to-end testing. Custom phantom designs have been implemented for assessment of the deep inspiration breath-hold workflow, the implanted markers workflow, and for gating tests where remote-controlled movement of a phantom is required. Commissioning tests were all found to be in tolerance, with maximum translational and rotational deviations in SGRT of 0.3 mm and 0.4°, respectively, and X-ray image fusion reproducibility standard deviation of 0.08 mm. Tolerances were based on published documents and upon the performance characteristics of the system as specified by the vendor. The unique configuration of ExacTrac Dynamic requires the end user to design commissioning tests that validate the system for use in the clinical implementation adopted in the department. As there are multiple customizable workflows available, tests should be designed around these workflows, and can be ongoing as workflows are progressively introduced into departmental procedures. Wolters Kluwer - Medknow 2022 2023-01-10 /pmc/articles/PMC9997535/ /pubmed/36908493 http://dx.doi.org/10.4103/jmp.jmp_67_22 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Perrett, Ben
Ukath, Jaysree
Horgan, Emma
Noble, Chris
Ramachandran, Prabhakar
A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title_full A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title_fullStr A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title_full_unstemmed A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title_short A Framework for ExacTrac Dynamic Commissioning for Stereotactic Radiosurgery and Stereotactic Ablative Radiotherapy
title_sort framework for exactrac dynamic commissioning for stereotactic radiosurgery and stereotactic ablative radiotherapy
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997535/
https://www.ncbi.nlm.nih.gov/pubmed/36908493
http://dx.doi.org/10.4103/jmp.jmp_67_22
work_keys_str_mv AT perrettben aframeworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT ukathjaysree aframeworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT horganemma aframeworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT noblechris aframeworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT ramachandranprabhakar aframeworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT perrettben frameworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT ukathjaysree frameworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT horganemma frameworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT noblechris frameworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy
AT ramachandranprabhakar frameworkforexactracdynamiccommissioningforstereotacticradiosurgeryandstereotacticablativeradiotherapy