Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film

AIMS: Most brachytherapy treatment planning system (TPS) commissioning requires data input based on the American Association of Physicists in Medicine Task Group-43 formalism. The commissioning accuracy is very important for dose calculation. The aim of this study is the implementation of a brachyth...

Descripción completa

Detalles Bibliográficos
Autores principales: Lahlabou, Mohammed, Khelifi, Rachid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997537/
https://www.ncbi.nlm.nih.gov/pubmed/36908487
http://dx.doi.org/10.4103/jmp.jmp_30_22
_version_ 1784903274439114752
author Lahlabou, Mohammed
Khelifi, Rachid
author_facet Lahlabou, Mohammed
Khelifi, Rachid
author_sort Lahlabou, Mohammed
collection PubMed
description AIMS: Most brachytherapy treatment planning system (TPS) commissioning requires data input based on the American Association of Physicists in Medicine Task Group-43 formalism. The commissioning accuracy is very important for dose calculation. The aim of this study is the implementation of a brachytherapy TPS into a clinical environment and check the TPS calculated dose accuracy. SUBJECTS AND METHODS: After introducing data of the different catheters (CIS Bio International, Saclay, France), composed of several Cesium-137 Eckert and Ziegler BEBIG CSM-11 radioactive sources; for XiO (CMS, St. Louis) brachytherapy TPS, the TPS dose calculation accuracy was investigated by comparing between the TPS calculated dose distribution (DD) for all the catheters with (1) the measuring DD using EBT3 GAFChromic film and (2) calculating DD by egs_brachy (Electron Gamma Shower, National Research Council of Canada) Monte Carlo simulation. The phantom used for this study consists of six PTW slabs 30 cm × 30 cm × 1 cm of polymethyl methacrylate with a Delouche MEDpro applicator on the top. The TPS DD was calculated on the computed tomography scan of this phantom. STATISTICAL ANALYSIS USED: PTW VeriSoft version 6.0.1.7 (PTW-Freiburg, Germany) software was used for analyzing scanned films and to perform the comparison based on the gamma index distribution. RESULTS: For each catheter, the gamma index distribution showed agreement >95% of all pixels in both verification methods, with gamma ≤1. CONCLUSIONS: We confirm the commissioning accuracy and that the TPS can be used for clinical purposes.
format Online
Article
Text
id pubmed-9997537
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-99975372023-03-10 Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film Lahlabou, Mohammed Khelifi, Rachid J Med Phys Original Article AIMS: Most brachytherapy treatment planning system (TPS) commissioning requires data input based on the American Association of Physicists in Medicine Task Group-43 formalism. The commissioning accuracy is very important for dose calculation. The aim of this study is the implementation of a brachytherapy TPS into a clinical environment and check the TPS calculated dose accuracy. SUBJECTS AND METHODS: After introducing data of the different catheters (CIS Bio International, Saclay, France), composed of several Cesium-137 Eckert and Ziegler BEBIG CSM-11 radioactive sources; for XiO (CMS, St. Louis) brachytherapy TPS, the TPS dose calculation accuracy was investigated by comparing between the TPS calculated dose distribution (DD) for all the catheters with (1) the measuring DD using EBT3 GAFChromic film and (2) calculating DD by egs_brachy (Electron Gamma Shower, National Research Council of Canada) Monte Carlo simulation. The phantom used for this study consists of six PTW slabs 30 cm × 30 cm × 1 cm of polymethyl methacrylate with a Delouche MEDpro applicator on the top. The TPS DD was calculated on the computed tomography scan of this phantom. STATISTICAL ANALYSIS USED: PTW VeriSoft version 6.0.1.7 (PTW-Freiburg, Germany) software was used for analyzing scanned films and to perform the comparison based on the gamma index distribution. RESULTS: For each catheter, the gamma index distribution showed agreement >95% of all pixels in both verification methods, with gamma ≤1. CONCLUSIONS: We confirm the commissioning accuracy and that the TPS can be used for clinical purposes. Wolters Kluwer - Medknow 2022 2023-01-10 /pmc/articles/PMC9997537/ /pubmed/36908487 http://dx.doi.org/10.4103/jmp.jmp_30_22 Text en Copyright: © 2023 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Lahlabou, Mohammed
Khelifi, Rachid
Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title_full Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title_fullStr Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title_full_unstemmed Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title_short Commissioning Validation of a Brachytherapy Treatment Planning System with EGSnrc Monte Carlo Code and EBT3 GAFChromic Film
title_sort commissioning validation of a brachytherapy treatment planning system with egsnrc monte carlo code and ebt3 gafchromic film
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997537/
https://www.ncbi.nlm.nih.gov/pubmed/36908487
http://dx.doi.org/10.4103/jmp.jmp_30_22
work_keys_str_mv AT lahlaboumohammed commissioningvalidationofabrachytherapytreatmentplanningsystemwithegsnrcmontecarlocodeandebt3gafchromicfilm
AT khelifirachid commissioningvalidationofabrachytherapytreatmentplanningsystemwithegsnrcmontecarlocodeandebt3gafchromicfilm