Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST)
BACKGROUND: The one-minute sit-to-stand-test (1-min STST) is a quick, space saving test to evaluate functional capacity. Exercise testing plays an important role in the long-term follow-up of pulmonary hypertension (PH) patients and is currently evaluated using the six-minute-walk-test (6MWT). The a...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997887/ https://www.ncbi.nlm.nih.gov/pubmed/36893125 http://dx.doi.org/10.1371/journal.pone.0282697 |
_version_ | 1784903351761108992 |
---|---|
author | Kronberger, Christina Mousavi, Roya Anahita Öztürk, Begüm Willixhofer, Robin Dachs, Theresa-Marie Rettl, René Camuz-Ligios, Luciana Rassoulpour, Nima Krall, Christoph Litschauer, Brigitte Badr Eslam, Roza |
author_facet | Kronberger, Christina Mousavi, Roya Anahita Öztürk, Begüm Willixhofer, Robin Dachs, Theresa-Marie Rettl, René Camuz-Ligios, Luciana Rassoulpour, Nima Krall, Christoph Litschauer, Brigitte Badr Eslam, Roza |
author_sort | Kronberger, Christina |
collection | PubMed |
description | BACKGROUND: The one-minute sit-to-stand-test (1-min STST) is a quick, space saving test to evaluate functional capacity. Exercise testing plays an important role in the long-term follow-up of pulmonary hypertension (PH) patients and is currently evaluated using the six-minute-walk-test (6MWT). The aim of the study was to assess the convergent validity of the 1-min STST in patients with PH and its association with markers of PH severity. METHODS: We evaluated 106 PH patients with the 1-min-STST and 6MWT and measured cardiorespiratory parameters (heart rate, blood pressure, oxygen saturation) before and after test conduction. N-terminal pro brain-type natriuretic peptide (NT-proBNP), WHO functional class (WHO-FC) and mean pulmonary artery pressure (mPAP) were defined as markers of PH severity. RESULTS: Strong correlation was found between performances of 1-min STST and 6MWT (r = .711, p < .001), indicating convergent validity. Both tests were inversely associated with NT-proBNP (STST: r = -.405, p < .001; 6MWT: r = -.358, p < .001), WHO-FC (STST: r = -.591, p < .001; 6MWT: r = -.643, p < .001) and mPAP (STST: r = -.280, p < .001; 6MWT: r = -.250, p < .001). Significant changes in cardiorespiratory parameters were observed in both tests (all p < 0.001). Further the post-exercise cardiorespiratory parameters correlated strongly between the 1-min STST and 6MWT (all r ≥ .651, all p < .001). CONCLUSION: The 1-min STST demonstrated good convergent validity with the 6MWT and was associated with markers of PH severity. Furthermore, both exercise tests caused similar cardiorespiratory responses. |
format | Online Article Text |
id | pubmed-9997887 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-99978872023-03-10 Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) Kronberger, Christina Mousavi, Roya Anahita Öztürk, Begüm Willixhofer, Robin Dachs, Theresa-Marie Rettl, René Camuz-Ligios, Luciana Rassoulpour, Nima Krall, Christoph Litschauer, Brigitte Badr Eslam, Roza PLoS One Research Article BACKGROUND: The one-minute sit-to-stand-test (1-min STST) is a quick, space saving test to evaluate functional capacity. Exercise testing plays an important role in the long-term follow-up of pulmonary hypertension (PH) patients and is currently evaluated using the six-minute-walk-test (6MWT). The aim of the study was to assess the convergent validity of the 1-min STST in patients with PH and its association with markers of PH severity. METHODS: We evaluated 106 PH patients with the 1-min-STST and 6MWT and measured cardiorespiratory parameters (heart rate, blood pressure, oxygen saturation) before and after test conduction. N-terminal pro brain-type natriuretic peptide (NT-proBNP), WHO functional class (WHO-FC) and mean pulmonary artery pressure (mPAP) were defined as markers of PH severity. RESULTS: Strong correlation was found between performances of 1-min STST and 6MWT (r = .711, p < .001), indicating convergent validity. Both tests were inversely associated with NT-proBNP (STST: r = -.405, p < .001; 6MWT: r = -.358, p < .001), WHO-FC (STST: r = -.591, p < .001; 6MWT: r = -.643, p < .001) and mPAP (STST: r = -.280, p < .001; 6MWT: r = -.250, p < .001). Significant changes in cardiorespiratory parameters were observed in both tests (all p < 0.001). Further the post-exercise cardiorespiratory parameters correlated strongly between the 1-min STST and 6MWT (all r ≥ .651, all p < .001). CONCLUSION: The 1-min STST demonstrated good convergent validity with the 6MWT and was associated with markers of PH severity. Furthermore, both exercise tests caused similar cardiorespiratory responses. Public Library of Science 2023-03-09 /pmc/articles/PMC9997887/ /pubmed/36893125 http://dx.doi.org/10.1371/journal.pone.0282697 Text en © 2023 Kronberger et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kronberger, Christina Mousavi, Roya Anahita Öztürk, Begüm Willixhofer, Robin Dachs, Theresa-Marie Rettl, René Camuz-Ligios, Luciana Rassoulpour, Nima Krall, Christoph Litschauer, Brigitte Badr Eslam, Roza Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title | Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title_full | Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title_fullStr | Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title_full_unstemmed | Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title_short | Functional capacity testing in patients with pulmonary hypertension (PH) using the one-minute sit-to-stand test (1-min STST) |
title_sort | functional capacity testing in patients with pulmonary hypertension (ph) using the one-minute sit-to-stand test (1-min stst) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9997887/ https://www.ncbi.nlm.nih.gov/pubmed/36893125 http://dx.doi.org/10.1371/journal.pone.0282697 |
work_keys_str_mv | AT kronbergerchristina functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT mousaviroyaanahita functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT ozturkbegum functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT willixhoferrobin functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT dachstheresamarie functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT rettlrene functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT camuzligiosluciana functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT rassoulpournima functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT krallchristoph functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT litschauerbrigitte functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst AT badreslamroza functionalcapacitytestinginpatientswithpulmonaryhypertensionphusingtheoneminutesittostandtest1minstst |