Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition
In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of anti-Salmonella polyclona...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Microbiology and Biotechnology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9998200/ https://www.ncbi.nlm.nih.gov/pubmed/36655270 http://dx.doi.org/10.4014/jmb.2212.12011 |
_version_ | 1784903422639603712 |
---|---|
author | Park, Mi-Kyung |
author_facet | Park, Mi-Kyung |
author_sort | Park, Mi-Kyung |
collection | PubMed |
description | In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of anti-Salmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 μg/ml for ELISA and GB-LMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities. |
format | Online Article Text |
id | pubmed-9998200 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Society for Microbiology and Biotechnology |
record_format | MEDLINE/PubMed |
spelling | pubmed-99982002023-03-10 Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition Park, Mi-Kyung J Microbiol Biotechnol Research article In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of anti-Salmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 μg/ml for ELISA and GB-LMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities. The Korean Society for Microbiology and Biotechnology 2023-02-28 2023-01-12 /pmc/articles/PMC9998200/ /pubmed/36655270 http://dx.doi.org/10.4014/jmb.2212.12011 Text en Copyright © 2023 by the authors. Licensee KMB. https://creativecommons.org/licenses/by/4.0/This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research article Park, Mi-Kyung Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title | Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title_full | Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title_fullStr | Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title_full_unstemmed | Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title_short | Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition |
title_sort | comparison of gold biosensor combined with light microscope imaging system with elisa for detecting salmonella in chicken after exposure to simulated chilling condition |
topic | Research article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9998200/ https://www.ncbi.nlm.nih.gov/pubmed/36655270 http://dx.doi.org/10.4014/jmb.2212.12011 |
work_keys_str_mv | AT parkmikyung comparisonofgoldbiosensorcombinedwithlightmicroscopeimagingsystemwithelisafordetectingsalmonellainchickenafterexposuretosimulatedchillingcondition |