Cargando…

Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength

OBJECTIVES: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Ogawa, Masato, Matsumoto, Tsuyoshi, Harada, Risa, Yoshikawa, Ryo, Ueda, Yuya, Takamiya, Daiki, Sakai, Yoshitada
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JARM 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9998244/
https://www.ncbi.nlm.nih.gov/pubmed/36909302
http://dx.doi.org/10.2490/prm.20230008
_version_ 1784903432703836160
author Ogawa, Masato
Matsumoto, Tsuyoshi
Harada, Risa
Yoshikawa, Ryo
Ueda, Yuya
Takamiya, Daiki
Sakai, Yoshitada
author_facet Ogawa, Masato
Matsumoto, Tsuyoshi
Harada, Risa
Yoshikawa, Ryo
Ueda, Yuya
Takamiya, Daiki
Sakai, Yoshitada
author_sort Ogawa, Masato
collection PubMed
description OBJECTIVES: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. METHODS: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. RESULTS: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. CONCLUSIONS: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.
format Online
Article
Text
id pubmed-9998244
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher JARM
record_format MEDLINE/PubMed
spelling pubmed-99982442023-03-11 Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength Ogawa, Masato Matsumoto, Tsuyoshi Harada, Risa Yoshikawa, Ryo Ueda, Yuya Takamiya, Daiki Sakai, Yoshitada Prog Rehabil Med Original Article OBJECTIVES: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. METHODS: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. RESULTS: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. CONCLUSIONS: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings. JARM 2023-03-11 /pmc/articles/PMC9998244/ /pubmed/36909302 http://dx.doi.org/10.2490/prm.20230008 Text en 2023 The Japanese Association of Rehabilitation Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND) 4.0 License.
spellingShingle Original Article
Ogawa, Masato
Matsumoto, Tsuyoshi
Harada, Risa
Yoshikawa, Ryo
Ueda, Yuya
Takamiya, Daiki
Sakai, Yoshitada
Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title_full Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title_fullStr Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title_full_unstemmed Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title_short Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
title_sort reliability and validity of quadriceps muscle thickness measurements in ultrasonography: a comparison with muscle mass and strength
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9998244/
https://www.ncbi.nlm.nih.gov/pubmed/36909302
http://dx.doi.org/10.2490/prm.20230008
work_keys_str_mv AT ogawamasato reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT matsumototsuyoshi reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT haradarisa reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT yoshikawaryo reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT uedayuya reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT takamiyadaiki reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength
AT sakaiyoshitada reliabilityandvalidityofquadricepsmusclethicknessmeasurementsinultrasonographyacomparisonwithmusclemassandstrength