101por Bertsch, Matthias, Reuter, Christoph, Czedik-Eysenberg, Isabella, Berger, Angelika, Olischar, Monika, Bartha-Doering, Lisa, Giordano, Vito“…Conclusion: Our study reveals high noise levels of air supply at high flow rates and the boost of low frequencies within the incubator. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
102“…Repeating the scan with mask removed produces a small subject-specific bias in BOLD baseline signal from nasal air supply, which may be due to cognitive influence of airflow or cannula-induced hypoxia. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
103por Marín, Sabrina, Cortés, Mayra, Acosta, Mauricio, Delgado, Karla, Escuti, Camila, Ayma, Diego, Demergasso, Cecilia“…We demonstrated that molecular markers are useful for assessing limiting factors like nutrients and air supply, and the impact of the quality of recycled solutions. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
104“…Examinations carried out with outside temperatures above 12 °C were conducted in acceptable comfort conditions regardless of outside air supply and classroom occupancy. In these cases, the dissatisfaction rate was less than 10%. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
105“…Yet, long-range airborne transmission had the potential to infect other diners in the cafe, even resulting in super-spreading events. A fresh air supply of 12.1–17.0 L/s per person is recommended for the cafe to serve 4–20 diners concurrently to minimize infection risks due to aerosols. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
106por Huang, Jianxiang, Hao, Tongping, Liu, Xiao, Jones, Phil, Ou, Cuiyun, Liang, Weihui, Liu, Fuqiang“…The high quantity of viral plume exhaled by delta cases can create a high risk zone nearby, which, for a mixing ventilation system, cannot be easily mitigated by raising mixing rates or introducing fresh air supply. Such risks can be reduced by wearing an N95 respirator, less so for social distancing. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
107por Hurraß, J., Golmohammadi, R., Bujok, S., Bork, M., Thelen, F., Wagner, P., Exner, D., Schönfeld, C., Hornei, B., Kampf, G., Exner, M.“…Three months after the outbreak the RNA of SARS-CoV-2 was detected on 14 of 39 sampled indoor surfaces of the air ventilation system with Ct values between 34.9 and 41.9, but only at the air supply in the corridor (11 of 24 samples) and the air overflow in the door between the corridor and the residents’ rooms (three of 11 samples) but not at the air exhaust in the residents’ bathrooms. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
108“…This equation is difficult to apply to actual conditions because it requires measurement of the outdoor air supply rate, which vary with time and are difficult to quantify. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
109por Burdon, Jonathan, Budnik, Lygia Therese, Baur, Xaver, Hageman, Gerard, Howard, C. Vyvyan, Roig, Jordi, Coxon, Leonie, Furlong, Clement E., Gee, David, Loraine, Tristan, Terry, Alvin V., Midavaine, John, Petersen, Hannes, Bron, Denis, Soskolne, Colin L., Michaelis, Susan“…Whilst organophosphates have been the main subject of interest, oil and hydraulic fumes in the air supply also contain ultrafine particles, numerous volatile organic hydrocarbons and thermally degraded products. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
110“…BACKGROUND: Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
111Analysis of trace metal distribution in plants with lab-based microscopic X-ray fluorescence imagingpor Mijovilovich, Ana, Morina, Filis, Bokhari, Syed Nadeem, Wolff, Timo, Küpper, Hendrik“…The custom-made measuring chamber with continuous humidity and air supply coupled to devices for imaging chlorophyll fluorescence kinetic measurements enabled direct correlation of element distribution with photosynthesis. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
112por Aviv, Dorit, Chen, Kian Wee, Teitelbaum, Eric, Sheppard, Denon, Pantelic, Jovan, Rysanek, Adam, Meggers, Forrest“…In this research, we demonstrate the energy cost of increasing outdoor air supply with standard systems per COVID-19 recommendations and introduce an alternative HVAC paradigm that maximizes the decoupling of ventilation and thermal control. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
113“…Stratum ventilation refers to the ventilation mode that the air supply port on the side wall slightly higher than the height of the working area directly sends fresh air into the working breathing area. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
114por Bertone, M., Mikszewski, A., Stabile, L., Riccio, G., Cortellessa, G., d'Ambrosio, F.R., Papa, V., Morawska, L., Buonanno, G.“…Indeed, high crowding indexes (i.e. high numbers of people relative to the vehicle size), inadequate clean air supply, and frequent extended exposure durations make transport environments potential hotspots for transmission of respiratory infections. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
115por Liu, Jiaxing, Hao, Ming, Chen, Shulei, Yang, Yang, Li, Jian, Mei, Qi, Bian, Xin, Liu, Kun“…This study explains the impact of face masks and airflow on indoor exposure risks and further inspires potential measures for public health, for example, no individuals should sit near the air supply opening.…”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
116por Yang, Ying-Fei, Lin, Yi-Jun, You, Shu-Han, Lu, Tien-Hsuan, Chen, Chi-Yun, Wang, Wei-Min, Liao, Chung-Min“…We showed that inhalation rates of individuals proved crucial for influencing the transmissibility of SARS-CoV-2, followed by air supply rate and exposure time. We suggest a minimum air change per hour (ACH) of 7 h(−1) would be at least appropriate with current room volume requirements in healthcare buildings when indoor population number is < 10 and exposure time is < 1 h with one infector and low activity levels being considered. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
117por Zhang, Zhuona, Li, Xia, Lyu, Keyang, Zhao, Xiaoning, Zhang, Feng, Liu, Dong, Zhao, Yonggang, Gao, Fan, Hu, Jian, Xu, Dongqun“…The local side wall of the corridor adopted fan coil air conditioning, combined with fresh air supply and personnel walking, resulting in airflow flowing to Zone E. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
118por Duffy, Clodagh, Kidd, Andrew, Francis, Sarah, Tsim, Selina, McNaughton, Laura, Ferguson, Katie, Ferguson, Jenny, Rodgers, K Gary, McGroarty, Claire, Sayer, Robin, Blyth, Kevin G“…METHODS: An underwater seal chest drain bottle (R54500, Rocket Medical UK) was set up inside a 60-litre plastic box and connected via an airtight conduit to a medical air supply. A multichannel particle counter (TSI Aerotrak 9310 Aerosol Monitor) was placed inside the box, allowing measurement of particle count/cubic foot (pc/ft(3)) within six channel sizes: 0.3–0.5, 0.5–1, 1–3, 3–5, 5–10 and >10 μm. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
119por Buytaert, Jan, Collins, Paula, Abed Abud, Adam, Allport, Phil, Pazos Álvarez, Antonio, Akiba, Kazuyoshi, de Aguiar Francisco, Oscar Augusto, Bay, Aurelio, Bernard, Florian, Baron, Sophie, Bertella, Claudia, Brunner, Josef X., Bowcock, Themis, Buytaert-De Jode, Martine, Byczynski, Wiktor, De Carvalho, Ricardo, Coco, Victor, Collins, Ruth, Dikic, Nikola, Dousse, Nicolas, Dowd, Bruce, Dreimanis, Kārlis, Dumps, Raphael, Durante, Paolo, Fadel, Walid, Farry, Stephen, Fernàndez Prieto, Antonio, Fernàndez Tèllez, Arturo, Flynn, Gordon, Franco Lima, Vinicius, Frei, Raymond, Gallas Torreira, Abraham, García Chàvez, Tonatiuh, Gazis, Evangelos, Guida, Roberto, Hennessy, Karol, Henriques, Andre, Hutchcroft, David, Ilic, Stefan, Ivanovs, Artūrs, Jevtic, Aleksandar, Jimenez Dominguez, Emigdio, Joram, Christian, Kapusniak, Kacper, Lemos Cid, Edgar, Lindner, Jana, Lindner, Rolf, Ivàn Martínez Hernàndez, M., Meboldt, Mirko, Milovanovic, Marko, Mico, Sylvain, Morant, Johan, Morel, Michel, Männel, Georg, Murray, Dónal, Nasteva, Irina, Neufeld, Niko, Neuhold, Igor, Pardo-Sobrino López, Francisco, Pèrez Trigo, Eliseo, Pichel Jallas, Gonzalo, Pilorz, Edyta, Piquilloud, Lise, Pons, Xavier, Reiner, David, Règules Medel, Hector David, Rodríguez Ramírez, Saul, Rodíguez Cahuantzi, Mario, Roosens, Carl, Rostalski, Philipp, Sanders, Freek, Saucet, Eric, Schmid Daners, Marianne, Schmidt, Burkhard, Schoettker, Patrick, Schwemmer, Rainer, Schindler, Heinrich, Sharma, Archana, Sivakumaran, Derick, Sigaud, Christophe, Spitas, Vasilios, Steffen, Nicola, Svihra, Peter, Tejeda Muñoz, Guillermo, Tachatos, Nikolaos, Tsolakis, Efstratios, van Leemput, Jan, Vignaux, Laurence, Vasey, Francois, Woonton, Hamish, Wyllie, Ken“…The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
120“…CONCLUSIONS: Oxygen controls B. subtilis biomass growth, alternative electron acceptors utilisation and metabolites formation. Limited oxygen/air supply enabled the bacteria to donate excess electrons to nitrate or anode, leading to steered product spectrum. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto