Mostrando 261 - 280 Resultados de 597 Para Buscar '"Crate ', tiempo de consulta: 0.10s Limitar resultados
  1. 261
    por Bouquet, B, Callot, O, Nguyen-Ngoc, Hoan
    Publicado 1981
    “…The computer consists of a 2/25 or 3/25 CAMAC unit, which can be crate controller or branch driver. In normal use, it is connected to SA400 floppy disks and a terminal. …”
    Enlace del recurso
    Enlace del recurso
  2. 262
    por Whitbeck, A, Hirschauer, J
    Publicado 2015
    “…New on-detector QIE electronics cards will transmit data at 4.8 GHz to the new μHTR cards residing in μTCA crates in the CMS electronics cavern. The μTCA crates are controlled by the AMC13, which accepts system clock and trigger throttling control from the CMS global DAQ system. …”
    Enlace del recurso
    Enlace del recurso
  3. 263
    por Bielawski, Bartosz
    Publicado 2018
    “…Due to the limited amount of space and the moderate number of signals to be monitored, a standard approach with a full VME or Compact PCI crate has not been selected. Instead, small embedded industrial computers with Universal Serial Bus (USB) oscilloscopes chosen for the specific application have been installed. …”
    Enlace del recurso
    Enlace del recurso
  4. 264
    por Bocci, Valerio
    Publicado 2015
    “…The present system in charge of controlling Muon detector Front-End (FE) Electronics consists of 10 Crates of equipment; each crate contains two kinds of modules: a Pulse Distribution Module (PDM) and up to 20 Service Boards (SB) connected via a custom Backplane for a total amount of about 800 microcontrollers[2]. …”
    Enlace del recurso
    Enlace del recurso
  5. 265
    por Matsushita, Takashi
    Publicado 2017
    “…The Global Trigger has been upgraded with state-of-the-art FPGA processors on Advanced Mezzanine Cards with optical links running at 10 GHz in a MicroTCA crate. The powerful processing resources of the upgraded system enable implementation of more algorithms at a time than previously possible, allowing CMS to be more flexible in how it handles the available trigger bandwidth. …”
    Enlace del recurso
    Enlace del recurso
  6. 266
  7. 267
    “…SIMPLE SUMMARY: Farrowing crates—narrow cages where sows are kept during lactation—impede the sow in the expression of natural behaviours and, therefore, cause animal welfare concerns. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 268
    “…Puppies aged 16 weeks were most commonly reported to sleep in a kennel/crate, but dogs aged 12 months most often slept in a dog bed. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 269
    por Matveev, Mikhail, Lee, S J, Padley, P
    Publicado 2007
    “…For example, the triggering system of the Cathode Strip Chamber (CSC) sub-detector at the CMS experiment comprises the onchamber anode and cathode electronics, the off-chamber boards housed in 9U crates mounted on the periphery of the Endcap iron disks, and one Track Finder (TF) crate located in the underground counting room (Fig.1). …”
    Enlace del recurso
    Enlace del recurso
  10. 270
    por Cittolin, S, Löfstedt, B, Zurfluh, E
    Publicado 1981
    “…As an economical system, it is running as an ancillary serial loop-link between microprocessors, like Data Acquisition Crate Controllers and systems with distributed intelligence. …”
    Enlace del recurso
  11. 271
    “…The RCT hardware consists of one clock distribution crate and 18 double-sided crates containing custom boards, ASICs, and backplanes. …”
    Enlace del recurso
    Enlace del recurso
  12. 272
    por Kretz, Moritz
    Publicado 2012
    “…While the idea of employing pairs of VME based Read-Out Driver (ROD) and Back of Crate (BOC) cards in the read-out chain remains unchanged, modifications regarding the IBL calibration procedure were introduced to overcome current hardware limitations. …”
    Enlace del recurso
  13. 273
    por Chen, S
    Publicado 2014
    “…The Readout-Driver card (ROD), the Back-of-Crate card (BOC), and the S-Link together form the essential frontend data path of the IBL’s off-detector DAQ system. …”
    Enlace del recurso
  14. 274
    “…The Read-Out Driver card (ROD), the Back-of-Crate card (BOC), and the S-Link together form the essential frontend data path of the IBL’s off-detector DAQ system. …”
    Enlace del recurso
  15. 275
    por Bachtis, M, Campos, D, Jones, J, Tepper, M
    Publicado 2022
    “…The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. …”
    Enlace del recurso
    Enlace del recurso
  16. 276
    por Le Gras, M, Williams, D J
    Publicado 1997
    “…The data treatment is performed as a real-time task in a VME crate equipped with a Motorola MVME147 CPU board and conforms to the standard instrumentation protocol as well as the PS control system.…”
    Enlace del recurso
  17. 277
    “…Among them are thresholds to send raw data samples to the ROB and/or to the local ROD crate controller, thresholds to histogram raw or processed variables. …”
    Enlace del recurso
  18. 278
    “…The 1M-wide ADD-32 module contains the electronics for 32 wires that makes it possible to place up to 672 data channels in the CAMAC crate with a standard bus. To amplify signals, Amp1 8.3 8-channel microcircuits are used. …”
    Enlace del recurso
  19. 279
    “…As an economical system, it is running as an ancillary serial loop-link between microprocessors, like data acquisition crate controllers and systems with distributed intelligence. …”
    Enlace del recurso
    Enlace del recurso
  20. 280
    por Horne, P J
    Publicado 1977
    “…The two computers are linked by a CAMAC crate system, which provides the means of access to mu P applications in CAMAC and the interface of the development system to other applications. (11 refs).…”
    Enlace del recurso
    Enlace del recurso
Herramientas de búsqueda: RSS