Mostrando 441 - 460 Resultados de 895 Para Buscar '"NIST"', tiempo de consulta: 0.09s Limitar resultados
  1. 441
    por Berg, Robert F., Tison, Stuart A.
    Publicado 2004
    “…The two standards, which have standard uncertainties of 0.019 %, agree to within combined uncertainties with each other and with a third primary standard at NIST based on pressure measurements at constant volume.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  2. 442
    “…The National Institute of Standards and Technology (NIST) watt balance experiment completed a determination of Planck constant in 1998 with a relative standard uncertainty of 87 × 10(−9) (k = 1), concurrently with an upper limit on the drift rate of the SI kilogram mass standard. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  3. 443
    por Johnson, Aaron, Kegel, Tom
    Publicado 2004
    “…This facility measures flow with nine turbine meter standards, each of which is traceable to the NIST primary flow standard. The flow capacity of this facility ranges from 0.7 actual m(3)/s to 10.7 actual m(3)/s at nominal pressures of 7174 kPa and at ambient temperatures. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  4. 444
    “…A major factor in inhibiting more rapid growth has been the inability to make comparable fluorescence intensity measurements across laboratories. NIST recognizes the need to develop and provide primary fluorescence intensity standard (FIS) reference materials to the scientific and technical communities involved in these assays. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 445
    por Jabbour, Z. J., Yaniv, S. L.
    Publicado 2001
    “…This paper describes the facilities, measurement capabilities, and ongoing research activities in the areas of mass and force at the National Institute of Standards and Technology (NIST). The first section of the paper is devoted to mass metrology and starts with a brief historical perspective on the developments that led to the current definition of the kilogram. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 446
    por Parr, Albert C.
    Publicado 2001
    “…This paper will review the status of the NIST implementation of the technical changes mandated by the 1979 redefinition of the candela and its effect upon the maintenance and dissemination of optical radiation measurements.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 447
    por Peiser, H. Steffen
    Publicado 2001
    “…Throughout the past century NBS/NIST supported a great variety of research studies in crystallography where the aim was the highest attainable accuracy in measurements. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 448
    por Rose, A. H., Wang, C.-M., Dyer, S. D.
    Publicado 2000
    “…NIST has administered the first round robin of measurements for optical fiber Bragg gratings. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 449
    “…Recently, a facility using radio-frequency induction heating for melting and filling the blackbody crucible with the freeze metal under vacuum conditions was developed at the National Institute of Standards and Technology (NIST). The blackbody development under a vacuum environment eliminated the possibility of contamination of the freeze metal during the process. …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 450
    por Estler, W. Tyler
    Publicado 1998
    “…We derive closed-form expressions for the combined standard uncertainties of angle calibrations, following guidelines published by the International Organization for Standardization (ISO) and NIST. The analysis includes methods for the quantitative evaluation of the standard uncertainty of small angle measurement using electronic autocollimators, including the effects of calibration uncertainty and air turbulence.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  11. 451
    por Jeffery, A., Shields, J. Q., Lee, L. H.
    Publicado 1998
    “…The new four-terminal-pair bridge requires fewer auxiliary balances than the present four-terminal-pair bridge employed at NIST, which makes it much easier to use. This new design can be used to compare capacitance, resistance, and inductance standards.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 452
    “…This paper describes the facility and specialized procedures used at NIST for the determination of test voltage divider ratios through comparative techniques. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  13. 453
    “…The intercomparison was conducted under the auspices of the Comité Consultatif de Photometrie et Radiometrie (CCPR) of the Comité International des Poids et Mesures, and the National Institute of Standards and Technology (NIST) served as the pilot laboratory. The spectral range of the intercomparison was 250 to 2400 nm and the transfer standards used were commercial tungsten-halogen lamps of two types. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 454
    por Lindstrom, Richard M.
    Publicado 1993
    “…As a result of a compact sample-detector geometry, the sensitivity (counting rate per gram of analyte) is a factor of four better than the existing Maryland-NIST thermal-neutron instrument at this reactor. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  15. 455
  16. 456
    “…After the overlapping chromatographic peaks were resolved into pure chromatograms and spectra using a heuristic evolving latent projections (HELP) method, qualitative analysis was performed by similarity search of the obtained pure mass spectrum of each component in the NIST library and the quantitative results were obtained by calculating the total two-way response volume. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  17. 457
    “…We evaluate the proposed features in a speaker verification task performed on NIST SRE 2010 data. The biomimetic approach yields significant robustness in presence of non-stationary noise and reverberation, offering a new framework for deriving reliable features for speaker recognition and speech processing.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  18. 458
    “…The results of the present study compared with standard reference material NIST1515 apple leaves for accuracy. The elements K, Ca, Cl, S and P are major constituents and besides Cu, Zn, Fe, Mn, Se, Br, Rb and Sr were present at low level. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  19. 459
    “…The effects of the accumulated dose on these TRNGs, an in particular, its repercussion over their randomness quality (e.g., entropy or linear complexity), have been evaluated by using two National Institute of Standards and Technology (NIST) statistical test suites. The obtained results clearly show how the degradation of the statistical properties of these TRNGs increases with the accumulated dose. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  20. 460
    por Wang, Juan, Ding, Qun
    Publicado 2018
    “…Through linear and differential cryptographic analysis, ciphertext information entropy, “0–1” balance and National Institute of Science and Technology (NIST) tests and the comparison with other traditional and lightweight block ciphers, the results indicate that the dynamic variety of encrypted rounds can achieve different levels of encryption for different information, which can achieve the purpose of enhancing the anti-attack ability and reducing the number of encrypted rounds. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS