2021por Lovo, Eduardo E, Barahona, Kaory C, Campos, Fidel, Caceros, Victor, Tobar, Carlos, Reyes, William A“…Single-session stereotactic radiosurgery (SRS) might not provide an adequate dose for long-term local control due to the initial tumor volume and the involvement of radiation sensitive organs at risk (OARs). Two-session radiosurgery has been described as a feasible strategy for dose escalation in large secondary brain tumors. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2022por Oktay, Ozan, Nanavati, Jay, Schwaighofer, Anton, Carter, David, Bristow, Melissa, Tanno, Ryutaro, Jena, Rajesh, Barnett, Gill, Noble, David, Rimmer, Yvonne, Glocker, Ben, O’Hara, Kenton, Bishop, Christopher, Alvarez-Valle, Javier, Nori, Aditya“…IMPORTANCE: Personalized radiotherapy planning depends on high-quality delineation of target tumors and surrounding organs at risk (OARs). This process puts additional time burdens on oncologists and introduces variability among both experts and institutions. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2023por Liu, Yaoying, Chen, Zhaocai, Wang, Jinyuan, Wang, Xiaoshen, Qu, Baolin, Ma, Lin, Zhao, Wei, Zhang, Gaolong, Xu, Shouping“…PURPOSE: This study focused on predicting 3D dose distribution at high precision and generated the prediction methods for nasopharyngeal carcinoma patients (NPC) treated with Tomotherapy based on the patient-specific gap between organs at risk (OARs) and planning target volumes (PTVs). METHODS: A convolutional neural network (CNN) is trained using the CT and contour masks as the input and dose distributions as output. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2024por Wei, Zhigong, Peng, Xingchen, He, Ling, Wang, Jingjing, Liu, Zheran, Xiao, Jianghong“…When comparing the D (max) of organs at risk (OARs), VMAT(6/10‐MV) was 18.32%–47.95% lower than IMRT(6/10‐MV) for almost all OARs. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2025Feasibility study: spot-scanning proton arc therapy (SPArc) for left-sided whole breast radiotherapypor Chang, Sheng, Liu, Gang, Zhao, Lewei, Dilworth, Joshua T., Zheng, Weili, Jawad, Saada, Yan, Di, Chen, Peter, Stevens, Craig, Kabolizadeh, Peyman, Li, Xiaoqiang, Ding, Xuanfeng“…The RMSD volume histogram (RVH) analysis shows SPArc provided better plan robustness in OARs sparing, including the heart, LAD, ipsilateral lung, and skin. …”
Publicado 2020
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2026
-
2027por Lindell, Kathleen Oare, Madisetti, Mohan, Fasolino, Tracy, Pittman, MaryChris, Coyne, Patrick, Whelan, Timothy P.M., Mueller, Martina, Ford, Dee W.Enlace del recurso
Publicado 2023
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2028por Kawula, Maria, Vagni, Marica, Cusumano, Davide, Boldrini, Luca, Placidi, Lorenzo, Corradini, Stefanie, Belka, Claus, Landry, Guillaume, Kurz, Christopher“…This study compared deep learning methods for auto-segmentation of organs-at-risk (OARs) and clinical target volume (CTV) in prostate cancer patients undergoing fractionated magnetic resonance (MR)-guided adaptive radiation therapy. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2029por Das, Jahnabi, Mishra, Shantanu K, Singh, Moirangthem N, Bhattacharyya, Mouchumee, Yanthan, Yanpothung, Kalita, Apurba K“…PTVs and organs at risk (OARs), including both lungs, esophagus, spinal cord, heart, and left anterior descending coronary artery (LAD), both atria and ventricles were contoured. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2030por Sankaralingam, Marimuthu, Glegg, Martin, Smith, Suzanne, James, Allan, Rizwanullah, Mohammed“…There was no significant difference in dose between IMRT and VMAT plans for any of the OARs assessed in these patients. The monitor units were significantly reduced in the VMAT plan in comparison to the IMRT plan for four out of five patients, with mean reduction of 66%. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2031por Kang, Sang Won, Chung, Jin Beom, Kim, Jae Sung, Kim, In Ah, Eom, Keun Yong, Song, Changhoon, Lee, Jeong Woo, Kim, Jin Young, Suh, Tae Suk“…Dosimetric and radiobiological metrics for target volumes and organs at risk (OARs) were evaluated from dosevolume histograms. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2032“…All patients were CT‐ and MR‐scanned with a ring applicator in situ. HR‐CTV and OARs were contoured according to fused CT and MR images. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2033por Francis, Samual R., Anker, Christopher J., Wang, Brian, Williams, Greg V., Cox, Kristen, Adler, Douglas G., Shrieve, Dennis C., Salter, Bill J.“…It is the purpose of this study to evaluate how self‐expanding stents (SESs) affect esophageal cancer radiation planning target volumes (PTVs) and dose delivered to surrounding organs at risk (OARs). Ten patients were evaluated, for whom a SES was placed before radiation. …”
Publicado 2013
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2034por Chen, Xinyuan, Jin, Dawei, Wang, Shulian, Li, Minghui, Huang, Peng, Dai, Jianrong“…Compared with the conventional AP–PA plan, Nonco_IMRT had better PTV coverage and OARs sparing, except for being larger in V5 to breast and lung. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2035por Yang, Chengwen, Liu, Ransheng, Ming, Xin, Liu, Ningbo, Guan, Yong, Feng, Yuanming“…PURPOSE: To investigate the dose depositions to organs at risk (OARs) and associated cancer risk in cancer patients scanned with 4-dimensional computed tomography (4DCT) as compared with conventional 3DCT. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2036por Cole, Aidan Joseph, Hardcastle, Nicholas, Turgeon, Guy-Anne, Thomas, Roshini, Irving, Louis B., Jennings, Barton R., Ball, David, Kron, Tomas, Steinfort, Daniel P., Siva, Shankar“…Radiotherapy plans investigated tumour coverage and dose to critical organs at risk (OARs) using PET-CT alone in comparison to PET-CT and EBUS-TBNA. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2037“…To obtain good clinical outcomes, tight dosimetric constraints are placed on organs at risk (OARs) to maximize tumor control and minimize normal tissue complication probabilities. …”
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2038por Henderson, Edward G.A., Vasquez Osorio, Eliana M., van Herk, Marcel, Green, Andrew F.“…BACKGROUND AND PURPOSE: Convolutional neural networks (CNNs) are increasingly used to automate segmentation for radiotherapy planning, where accurate segmentation of organs-at-risk (OARs) is crucial. Training CNNs often requires large amounts of data. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2039por Kruszyna-Mochalska, Marta, Skrobala, Agnieszka, Romanski, Piotr, Ryczkowski, Adam, Suchorska, Wiktoria, Kulcenty, Katarzyna, Piotrowski, Igor, Borowicz, Dorota, Graczyk, Kinga, Matuszak, Natalia, Malicki, Julian“…For CyberKnife the highest doses were for gantry with caudal direction beams blocked (gantry close to OARs) while the lowest was the low modulated VOLO optimization technique. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
2040por Huiskes, Merle, Astreinidou, Eleftheria, Kong, Wens, Breedveld, Sebastiaan, Heijmen, Ben, Rasch, Coen“…Doses to the organs at risk (OARs) remained equal or decreased slightly after APT was applied. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto