-
241por Hines, Christina S., Liow, Jeih-San, Zanotti-Fregonara, Paolo, Hirvonen, Jussi, Morse, Cheryl, Pike, Victor W., Innis, Robert B.“…Eleven source organs (brain, heart, liver, pancreas, stomach, spleen, lungs, kidneys, lumbar spine L1-5, thyroid, and urinary bladder) were identified on whole body images and used to calculate radiation doses using the software program OLINDA/EXM 1.1. To confirm that we had correctly identified the pancreas, a tenth subject was imaged on a PET/CT device. …”
Publicado 2011
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
242por Tsai, Chia-Che, Chang, Chih-Hsien, Chen, Liang-Cheng, Chang, Ya-Jen, Lan, Keng-Li, Wu, Yu-Hsien, Hsu, Chin-Wei, Liu, I-Hsiang, Ho, Chung-Li, Lee, Wan-Chi, Ni, Hsiao-Chiang, Chang, Tsui-Jung, Ting, Gann, Lee, Te-Wei“…Pharmacokinetics study was described by a noncompartmental model. The OLINDA|EXM(®) computer program was used for the dosimetry evaluation. …”
Publicado 2011
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
243por Rizvi, Saiyada N. F., Visser, Otto J., Vosjan, Maria J. W. D., van Lingen, Arthur, Hoekstra, Otto S., Zijlstra, Josée M., Huijgens, Peter C., van Dongen, Guus A. M. S., Lubberink, Mark“…Ibritumomab tiuxetan organ absorbed doses were calculated using OLINDA. Red marrow dosimetry was based on blood samples. …”
Publicado 2012
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
244por Quinn, Brian, Dauer, Zak, Pandit-Taskar, Neeta, Schoder, Heiko, Dauer, Lawrence T.“…PET dose was calculated by modifying the standard reference phantoms in OLINDA/EXM 1.1 with patient-specific organ mass. CT dose was calculated using patient-specific data in ImPACT. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
245por Kratochwil, Clemens, Schmidt, Karl, Afshar-Oromieh, Ali, Bruchertseifer, Frank, Rathke, Hendrik, Morgenstern, Alfred, Haberkorn, Uwe, Giesel, Frederik L.“…The residence times of (213)Bi were forwarded to the instable daughter nuclides. OLINDA was used for dosimetry calculation. Results are discussed in comparison to literature data for (225)Ac-PSMA-617. …”
Publicado 2017
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
246por Ramesh, Anita, Cameron, Mary, Spence, Kirstin, Hoek Spaans, Remy, Melo-Santos, Maria A. V., Paiva, Marcelo H. S., Guedes, Duschinka R. D., Barbosa, Rosangela M. R., Oliveira, Claudia M. F., Sá, André, Jeffries, Claire L., Castanha, Priscila M. S., Oliveira, Paula A. S., Walker, Thomas, Alexander, Neal, Braga, Cynthia“…METHODS: Experiments occurred within two densely populated urban areas of Olinda, RMR, in July and August 2015. U.S. Centers for Disease Control and Prevention (CDC) light traps were compared to battery-powered aspirators as collection methods, and mosquito dispersion was measured by mosquito mark release recapture (MMRR). …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
247por Santos-Cuevas, Clara, Ferro-Flores, Guillermina, García-Pérez, Francisco O., Jiménez-Mancilla, Nallely, Ramírez-Nava, Gerardo, Ocampo-García, Blanca, Luna-Gutiérrez, Myrna, Azorín-Vega, Erika, Davanzo, Jenny, Soldevilla-Gallardo, Irma“…N data were the input for the OLINDA/EXM code to calculate internal radiation doses. …”
Publicado 2018
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
248por Wang, Shyh-Jen, Huang, Wen-Sheng, Chuang, Chi-Mu, Chang, Chih-Hsien, Lee, Te-Wei, Ting, Gann, Chen, Ming-Huang, Chang, Peter Mu-Hsin, Chao, Ta-Chung, Teng, Hao-Wei, Chao, Yee, Chen, Yuh-Min, Lin, Tzu-Ping, Chang, Ya-Jen, Chen, Su-Jung, Huang, Yuan-Ruei, Lan, Keng-Li“…The effectiveness with which tumors are targeted, the pharmacokinetics, biodistribution, dosimetry, and safety are evaluated using the VelocityAI and OLINDA/EXM software. Blood samples are collected at different time points for a pharmacokinetics study and a safety evaluation that involves monitoring changes in liver, renal, and hematological functions. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
249por Johansen, Annette, Holm, Søren, Dall, Bente, Keller, Sune, Kristensen, Jesper L., Knudsen, Gitte M., Hansen, Hanne D.“…Time-integrated activity coefficients (TIACs) from time-activity curves (TACs) of selected organs were used as input into the OLINDA/EXM software to obtain dosimetry information for both (11)C-labeling positions of Cimbi-36. …”
Publicado 2019
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
250por Viitanen, Riikka, Moisio, Olli, Lankinen, Petteri, Li, Xiang-Guo, Koivumäki, Mikko, Suilamo, Sami, Tolvanen, Tuula, Taimen, Kirsi, Mali, Markku, Kohonen, Ia, Koskivirta, Ilpo, Oikonen, Vesa, Virtanen, Helena, Santalahti, Kristiina, Autio, Anu, Saraste, Antti, Pirilä, Laura, Nuutila, Pirjo, Knuuti, Juhani, Jalkanen, Sirpa, Roivainen, Anne“…Radiation doses were calculated using the OLINDA/EXM software, version 2.2. In addition, a patient with early rheumatoid arthritis was studied with both (68)Ga-DOTA-Siglec-9 and (18)F-FDG PET/CT to determine the ability of the new tracer to detect arthritis. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
251por Merkx, Robin I. J., Lobeek, Daphne, Konijnenberg, Mark, Jiménez-Franco, Luis David, Kluge, Andreas, Oosterwijk, Egbert, Mulders, Peter F.A., Rijpkema, Mark“…Dosimetry analysis using OLINDA/EXM 2.1 showed that the organs receiving the highest doses (mean ± SD) were the liver (1.86 ± 0.40 mGy/MBq), the kidneys (1.50 ± 0.22 mGy/MBq) and the heart wall (1.45 ± 0.19 mGy/MBq), with a mean whole body effective dose of 0.57 ± 0.08 mSv/MBq. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
252por Giesel, Frederik L., Adeberg, Sebastian, Syed, Mustafa, Lindner, Thomas, Jiménez-Franco, Luis David, Mavriopoulou, Eleni, Staudinger, Fabian, Tonndorf-Martini, Eric, Regnery, Sebastian, Rieken, Stefan, El Shafie, Rami, Röhrich, Manuel, Flechsig, Paul, Kluge, Andreas, Altmann, Annette, Debus, Jürgen, Haberkorn, Uwe, Kratochwil, Clemens“…Absorbed doses were evaluated using OLINDA/EXM, version 1.1, and QDOSE dosimetry software with the dose calculator IDAC-Dose, version 2.1. …”
Publicado 2021
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
253por Zhao, Liang, Niu, Bo, Fang, Jianyang, Pang, Yizhen, Li, Siyang, Xie, Chengrong, Sun, Long, Zhang, Xianzhong, Guo, Zhide, Lin, Qin, Chen, Haojun“…The effective dose of (68)Ga-DOTA-2P(FAPI)(2) was 1.19E−02 mSv/MBq, calculated using OLINDA. Finally, the PET/CT scans of the 3 cancer patients revealed higher intratumoral uptake of (68)Ga-DOTA-2P(FAPI)(2) than of (68)Ga-FAPI-46 in all tumor lesions (SUV(max), 8.1–39.0 vs. 1.7–24.0, respectively; P < 0.001). …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
254por Suh, Minseok, Ryoo, Hyun Gee, Kang, Keon Wook, Jeong, Jae Min, Jeong, Chang Wook, Kwak, Cheol, Cheon, Gi Jeong“…In healthy adults, absorbed organ doses and effective doses were calculated using the OLINDA/EXM software. In patients with prostate cancer, the rates of detecting suspicious lesions by (68)Ga-NGUL PET/CT and conventional imaging (CT and bone scintigraphy) during the screening period, within one month after recruitment, were compared. …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
255por Tremblay, Sébastien, Beaudoin, Jean-François, Bélissant Benesty, Ophélie, Ait-Mohand, Samia, Dumulon-Perreault, Véronique, Rousseau, Étienne, Turcotte, Éric E., Guérin, Brigitte“…The dosimetry calculated with OLINDA for cyclotron- and generator-produced (68)Ga-DOTATATE was roughly equivalent. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
256por van Sluis, Joyce, Noordzij, Walter, de Vries, Elisabeth G. E., Kok, Iris C., de Groot, Derk Jan A., Jalving, Mathilde, Lub-de Hooge, Marjolijn N., Brouwers, Adrienne H., Boellaard, Ronald“…The residence times served as input for OLINDA/EXM version 1.0 (Vanderbilt University, 2003) to calculate the whole-body effective dose (mSv/MBq). …”
Publicado 2022
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
257por Luong, Thien Vinh, Nielsen, Erik Nguyen, Falborg, Lise, Kjærulff, Mette Louise Gram, Tolbod, Lars Poulsen, Søndergaard, Esben, Møller, Niels, Munk, Ole Lajord, Gormsen, Lars Christian“…Dosimetry estimates of [(11)C]OHB was calculated using OLINDA/EXM software, biodistribution was assessed visually and [(11)C]OHB tissue kinetics were obtained using an arterial input function and tissue time-activity curves. …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
258por Liu, Yu, Zhang, Qian, Zhang, Yuwei, Wang, Jingnan, Wu, Yitian, Yang, Guangjie, Shi, Jiyun, Wang, Fan, Xu, Zuojun, Jing, Hongli“…Dosimetry was calculated using OLINDA/EXM software (version 2.0; HERMES Medical Solutions). …”
Publicado 2023
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
259por Velikyan, Irina, Rosenström, Ulrika, Bulenga, Thomas N., Eriksson, Olof, Antoni, Gunnar“…The resulting data were extrapolated for the estimation of human organ and total body absorbed and total effective doses using Organ Level Internal Dose Assessment Code software (OLINDA/EXM 1.1) assuming a similar organ distribution pattern between the species. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto -
260por Kranz, Mathias, Sattler, Bernhard, Tiepolt, Solveig, Wilke, Stephan, Deuther-Conrad, Winnie, Donat, Cornelius K., Fischer, Steffen, Patt, Marianne, Schildan, Andreas, Patt, Jörg, Smits, René, Hoepping, Alexander, Steinbach, Jörg, Sabri, Osama, Brust, Peter“…Time-activity curves (TACs) were obtained from the three species, the animal data extrapolated to human scale, exponentially fitted and the organ doses (OD), and effective dose (ED) calculated with OLINDA. RESULTS: The excreting organs (urinary bladder, kidneys, and liver) receive the highest organ doses in all species. …”
Publicado 2016
Enlace del recurso
Enlace del recurso
Enlace del recurso
Online Artículo Texto