Mostrando 241 - 260 Resultados de 288 Para Buscar '"Olinda"', tiempo de consulta: 0.14s Limitar resultados
  1. 241
    “…Eleven source organs (brain, heart, liver, pancreas, stomach, spleen, lungs, kidneys, lumbar spine L1-5, thyroid, and urinary bladder) were identified on whole body images and used to calculate radiation doses using the software program OLINDA/EXM 1.1. To confirm that we had correctly identified the pancreas, a tenth subject was imaged on a PET/CT device. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  2. 242
  3. 243
  4. 244
    “…PET dose was calculated by modifying the standard reference phantoms in OLINDA/EXM 1.1 with patient-specific organ mass. CT dose was calculated using patient-specific data in ImPACT. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 245
    “…The residence times of (213)Bi were forwarded to the instable daughter nuclides. OLINDA was used for dosimetry calculation. Results are discussed in comparison to literature data for (225)Ac-PSMA-617. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 246
    “…METHODS: Experiments occurred within two densely populated urban areas of Olinda, RMR, in July and August 2015. U.S. Centers for Disease Control and Prevention (CDC) light traps were compared to battery-powered aspirators as collection methods, and mosquito dispersion was measured by mosquito mark release recapture (MMRR). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 247
  8. 248
    “…The effectiveness with which tumors are targeted, the pharmacokinetics, biodistribution, dosimetry, and safety are evaluated using the VelocityAI and OLINDA/EXM software. Blood samples are collected at different time points for a pharmacokinetics study and a safety evaluation that involves monitoring changes in liver, renal, and hematological functions. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 249
    “…Time-integrated activity coefficients (TIACs) from time-activity curves (TACs) of selected organs were used as input into the OLINDA/EXM software to obtain dosimetry information for both (11)C-labeling positions of Cimbi-36. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 250
    “…Radiation doses were calculated using the OLINDA/EXM software, version 2.2. In addition, a patient with early rheumatoid arthritis was studied with both (68)Ga-DOTA-Siglec-9 and (18)F-FDG PET/CT to determine the ability of the new tracer to detect arthritis. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  11. 251
    “…Dosimetry analysis using OLINDA/EXM 2.1 showed that the organs receiving the highest doses (mean ± SD) were the liver (1.86 ± 0.40 mGy/MBq), the kidneys (1.50 ± 0.22 mGy/MBq) and the heart wall (1.45 ± 0.19 mGy/MBq), with a mean whole body effective dose of 0.57 ± 0.08 mSv/MBq. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 252
  13. 253
    “…The effective dose of (68)Ga-DOTA-2P(FAPI)(2) was 1.19E−02 mSv/MBq, calculated using OLINDA. Finally, the PET/CT scans of the 3 cancer patients revealed higher intratumoral uptake of (68)Ga-DOTA-2P(FAPI)(2) than of (68)Ga-FAPI-46 in all tumor lesions (SUV(max), 8.1–39.0 vs. 1.7–24.0, respectively; P < 0.001). …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 254
    “…In healthy adults, absorbed organ doses and effective doses were calculated using the OLINDA/EXM software. In patients with prostate cancer, the rates of detecting suspicious lesions by (68)Ga-NGUL PET/CT and conventional imaging (CT and bone scintigraphy) during the screening period, within one month after recruitment, were compared. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  15. 255
  16. 256
  17. 257
    “…Dosimetry estimates of [(11)C]OHB was calculated using OLINDA/EXM software, biodistribution was assessed visually and [(11)C]OHB tissue kinetics were obtained using an arterial input function and tissue time-activity curves. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  18. 258
  19. 259
    “…The resulting data were extrapolated for the estimation of human organ and total body absorbed and total effective doses using Organ Level Internal Dose Assessment Code software (OLINDA/EXM 1.1) assuming a similar organ distribution pattern between the species. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  20. 260
    “…Time-activity curves (TACs) were obtained from the three species, the animal data extrapolated to human scale, exponentially fitted and the organ doses (OD), and effective dose (ED) calculated with OLINDA. RESULTS: The excreting organs (urinary bladder, kidneys, and liver) receive the highest organ doses in all species. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS