Mostrando 241 - 260 Resultados de 333 Para Buscar '"Ostia"', tiempo de consulta: 0.42s Limitar resultados
  1. 241
  2. 242
    “…Also, aortic root changes could impact valve type and size selection, affecting the decision of over-sizing or under-sizing in order to prevent valve embolization or coronary ostia obstruction.…”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  3. 243
    “…He then underwent a transthoracic echocardiogram (TTE) which showed prosthetic valve dysfunction and subsequently underwent transesophageal echocardiogram (TEE) which revealed vegetations on all leaflets and circumferential peri-aortic abscess encompassing both coronary ostia and extending towards the tricuspid and mitral valve leaflets. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  4. 244
    “…OUTCOMES: The patients were both scheduled for a second-look hysteroscopy 1 to 3 months after surgery, which revealed normal morphology of the uterine cavities and tubal ostia. The patients both achieved normal intrauterine pregnancies several months after surgery. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  5. 245
    “…LAA analyses suggested that Indigenous Australians may have a greater proportion of non chickenwing LAA type, and a tendency for eccentric, oval-shaped LAA ostia; however, there were no other differences seen with regards to LAA volume or depth. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  6. 246
    por Kossard, Steven
    Publicado 2021
    “…Remarkably, only the superficial infundibular ostia remain, and the distended cavity is devoid of a follicular or sebaceous gland remnant. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  7. 247
    “…The transthoracic echocardiographic exam revealed two large aneurysms at the ostia of the coronary arteries. We performed further evaluation with transoesophageal echocardiogram and computed tomography (CT) angiography. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  8. 248
    “…The changes were statistically significant (p<0.05) in the axial diameter and the ostium area. The number of patent ostia increased after the intervention. The association between SNOT-22 score and ostium patency were statistically significant before the operation. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  9. 249
    “…Device embolization was performed to induce proximal and distal segmental false lumen thrombosis (FLT) apart from the level of the ostia of vital branches. Successful RBS was performed in 13 patients. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  10. 250
    “…BACKGROUND: The surgical ascending aorta repair according to the Cabrol procedure involves the interposition of a prosthetic conduit between the aortic prosthesis and the native coronary ostia. Previous cases of the Cabrol conduit stenosis have been described, most of which presented as acute coronary syndromes due to thrombotic occlusion of the graft. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  11. 251
    “…We evaluated the effect of endotherapic abamectin injected into infested stone pines in the Parco Archeologico di Ostia Antica (Rome). RESULTS: Results showed that endotherapic abamectin significantly reduced the pine tortoise adult female populations and had a persistence into plants of approximately 60 days. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  12. 252
  13. 253
    “…We evaluated the diagnostic performance and computation time of IVUS-FFR, and compared it with that of the FFR-branch (considering side branch blood flow by manually extending the side branch from the bifurcation ostia). We also compared the effects of three bifurcation fractal laws on the accuracy of IVUS-FFR. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  14. 254
    por Luo, Qingzhi, Xie, Yun, Wu, Liqun, Jin, Qi
    Publicado 2023
    “…Finally, bilateral circumferential ablation lines were delivered around the ipsilateral PV ostia to achieve complete PV isolation (PVI). CONCLUSIONS: This case demonstrates that AF catheter ablation under the guidance of the RMN system using ICE is feasible and safe in a patient with DSI. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  15. 255
    “…A customized 4-mm cutter was used to punch a circumferential and an axial dog-bone-shaped specimen from each segment; the aortic ostia and calcification were avoided. Instron 8,874 and digital image correlation were used to perform a uniaxial tensile test on each sample. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  16. 256
    “…GRAPHICAL ABSTRACT: High-risk aortic root anatomy did not trigger coronary ostia obstruction or coronary flow alteration after transcatheter aortic valve implantation in a surgical bioprosthesis as shown from in-vitro flow loop tests. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  17. 257
    “…It showed a generally reduced coronary flow with multiple significant stenoses (including the ostia of the left and right coronary artery), as well as a highly reduced left ventricular function with diffuse hypokinesia. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  18. 258
    “…The apex and the coronary ostia were used as landmarks. RESULTS: Image registration was successful in all datasets, and resulted in a mean registration error of 3.22 ± 1.86 mm between the MRI surface mesh and EMM points. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  19. 259
    “…To avoid intra-operative complications, no mobilization of coronary ostia was done. Additionally, the tubular aorta was kept minimally unchanged. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
  20. 260
    “…A Cook’s catheter, special fallopian tubal catheter, were used to recanalize the blocked tubes in 100 women (group A) under UGTR, and the same Cook’s tubal catheter was used through 2mm microhysteroscope to cannulate both ostia using MHOD in another 100 women (group B). …”
    Enlace del recurso
    Enlace del recurso
    Online Artículo Texto
Herramientas de búsqueda: RSS